Electrodes for Titration Which electrode for which application? Application Specifics Electrode Order no. Ecotrode Plus 6.0262.100 General Ecotrode Gel 6.0221.100 Alkaline samples, Bayer liquors. Titrations performed at high temperatures Unitrode 6.0259.100 Acidity of alcoholic beverages Unitrode easy Clean with Pt1000 6.0260.010 Aqueous acid/ Titrations with small sample volumes Flat membrane pH electrode 6.0256.100 base titrations Titrations in water having a low conductivity Aquatrode Plus 6.0253.100 Carbonate hardness, acid capacity of water, p- & m-value Aquatrode Plus with Pt1000 6.0257.600 Electroplating baths, etching baths, phosphate coating Profitrode 6.0255.100 Electroplating and etching baths containing fluoride or hydrofluoric acid Solitrode HF 6.0223.100 Protein-containing samples Porotrode 6.0235.200 Determination of the base number (TBN) of mineral oils, titrations with perchloric acid, cyclohexylamine, alcoholic HCl Solvotrode easy Clean with LiCl Non-aqueous sat in ethanol 6.0229.010 acid/base titrations Determination of the acid number (TAN) of mineral oils, titrations with alcoholic KOH, NaOH and TBAOH, Solvotrode easy Clean 6.0229.010 potassiummethylate, free acids; hydroxyl number of oils and fats c(TEABr) = 0.4 mol/L in ethylene glycol) (+ 6.2320.000) Redox titrations Titrations at constant pH value Pt-Titrode 6.0431.100 Arsenite, cerium sulfate, Redox titrations at varying pH value Combined Pt-ring-electrode 6.0451.100 iron(III), iodine, Chemical oxigen demand in water (ferrometry) Combined Au-ring-electrode 6.0452.100 potassium bromate, sodium nitrite, oxalic acid, Penicillin, ampicillin Combined Au-ring-electrode 6.0452.100 permanganate, thiosulfate, Titrations in Ipol mode Double Pt sheet electrode 6.0309.100 titan(III), Hg(NO3)2 Bromatometry, iodometry, cerimetry according to Ph. Eur. & USP Pt-Titrode 6.0431.100 Karl Fischer Titrations Water content according to Karl Fischer Double Pt-wire electrode (HF-resistant version on request) 6.0338.100 Complexometric Back-titration of the Ba2+ excess with EDTA Combined Ca2+ -ISE polymer membrane 6.0510.100 Titrations with Determination of Ca2+, Mg2+ (Application Bulletin 125) Combined Ca2+-ISE polymer membrane 6.0510.100 EDTA, Complexon© III and IV Determination of Al, Ba, Bi, Ca, Cd, Co, Fe, Mg, Ni, Pb, Zn (Application Bulletin 101) Cu2+ ISE – crystal membrane 6.0502.140 Chloride in general, sodium chloride in food Ag-Titrode 6.00430.100 Chloride in dialysis and infusion solutions Ag-Titrode with Ag2S-coating 6.00430.100S Precipitation titrations Titrations according to Ph.. Eur. & USP Ag-Titrode with Ag Titrations with 2S-coating 6.00430.100S silver nitrate Determination of hydrogen sulfide, mercaptans, carbonyl sulfide, sulfides Ag-Titrode with Ag2S-coating 6.00430.100S Chloride, bromide, iodide and cyanide in electroplating baths Ag-Titrode with Ag2S-coating 6.00430.100S Fluoride/hydrofluoric acid in etching baths F–-ISE crystal membrane 6.0502.150 Photometric titrations Titration in aqueous and non-aqueous media; choice of eight wave lengths (470, 502, 520, 574, 590, 610, 640, 660 mn) Optrode 6.1115.000 Surfactants in Titration of anionic and cationic surfactants, titrations in chloroform, surfactant formulations containing oils, pH <10 Surfactrode Resistant 6.0507.130 non-aqueous media Aromatic/aliphatic, hydrocarbons, ketones, chloroethanes, Titration of anionic and cationic surfactants, titration of washing agents, soaps, pH >10 Surfactrode Refill 6.0507.140 methylisobutylketone Titration of cationic surfactants Cationic Surfactant 6.0507.150 Surfactants in aqueous media Titration of anionic surfactants Ionic Surfactant 6.0507.120 Titration of non-ionic surfactants, titration of pharmaceutical ingredients with sodium tetraphenylborate NIO electrode 6.0507.010 Titrations in aqueous and non-aqueous solutions without HF Thermoprobe 6.9011.020 Thermometric titrations Titrations in aqueous solutions containing HF Thermoprobe HF 6.9011.040 Practical tips, care and maintenance of electrodes for titration Combined Ecotrode Plus Ecotrode Gel Unitrode Aquatrode Solvotrode Ag/Pt/Au- Surfactant Plus Profitrode easyClean Ag/Pt/ Surfactrodes Optrode Titrodes Au electrodes electrodes Fixed ground-joint Twin-pore diaphragma Fixed ground-joint Fixed ground-joint Ground-joint easy Clean diaphragm Maintenance-free pH Ceramic-pin For surfactant For surfactant Power supplied by diaphragm • For routine diaphragm diaphragm diaphragm • For titrations in glass reference system diaphragm titrations in non-titrations in aqueous titrator via USB, • Insensitive to measurements in • Very low alkali error • Rapid response • For difficult matrices nonaqueous • Also available as • For precipitation or aqueous media media no separate power contamination similar samples • Insensitive to in iondeficient or • Double-junction matrices micro-electrodes redox titrations with adapter needed • Attractive price/ • With lifetime contamination weakly buffered construction • Rapid response in with 6.4 mm change of pH value Surfactrode NIO electrode performance ratio indicator • High-temperature solutions organic solvents Resistant (6.0507.010)1) diameter • Maintenance-free resistance • Insensitive to • Electrically shielded (6.0507.130)1) For titration of non- Ordering Info: reference electrolyte contamination Resistant to chloro- ionic surfactants Ag-Titrode: (gel) Ordering Info: form and many other 6.0259.1001) 6.00430.1001) solvents. Ionic Surfactant (6.0507.120)1) Ordering Info: Ordering Info: 6.0258.600 Ordering Info: Ordering Info: Ordering Info: Pt-Titrode: Ordering Info: Surfactrode Refill Optimized for anionic Ordering Info: 6.0262.1001) 6.0221.1001) (with Pt1000)4) 6.0431.1001) 6.0253.1001) 6.0255.1001) 6.0229.010 Ag: 6.00450.1001) (6.0507.140)1) surfactants 6.1115.000 iEcotrode Plus: 6.0221.600 iUnitrode: 6.0257.600 (Fitting length = (1 m fixed cable) Micro-Au Titrode: Pt: 6.0451.1001) Refillable surfactant Cationic Surfactant Optional: 6.0280.3002) (with NTC)4) 6.0278.3002) (with Pt1000)4) 113 mm) 6.0229.020 electrode, thus 6.0435.1101) Au: 6.0452.1001) practically unlimited (6.0507.150)1) 6.2166.000 USB dEcotrode Plus: dUnitrode: iAquatrode Plus: 6.0255.1101) (2 m fixed cable) iAg-Titrode: working life. Optimized for cationic power supply unit 6.00201.3003) 6.00200.3003) 6.0277.3002) (Fitting length = iAg: 6.00450.3002) surfactants for titrators without 6.00470.3002) 170 mm) dSolvotrode: Not resistant to USB connector. Unitrode easy Clean: dAquatrode Plus: 6.00203.3003) iPt: 6.0451.3002) chloroform. iPt-Titrode: 6.0471.3002) 6.0260.010 6.00202.3003) 6.0255.1201) dAg: 6.00402.3003) Surfactrode refill dAg-Titrode: (with Pt1000, (Fitting length = paste: 6.2319.000 6.00404.3003) 1.2 m fixed cable) 310 mm) dPt: 6.00403.3003) dProfitrode: dPt-Titrode: 6.00204.3003) 6.00401.3003) Store in 6.2323.000 Store in 6.2308.000 Use 6.2308.040 Store in 6.2323.000 Store in bridge Store in reference Store in distilled water Store in reference Store dry. Store dry. Allow 5 minutes for storage solution only. KCl sat. Idrolyte for titrations storage solution only. electrolyte. electrolyte. only. electrolyte. Allow a few titrations Rinse with dist. water warming up the LED. Do not wipe electrode. Rinse with water or at temperatures Testing of the 80...100 °C or to Do not wipe electrode. Do not wipe electrode. Do not wipe electrode. Testing of the for conditioning of or 20% methanol in electrodes according For cleaning/care ethanol to remove suppress protein For cleaning/care For cleaning/care In case of contami- electrodes according the Surfactrodes. water. to AB-048. 6.2325.000 pHit kit contamination. precipitation by KCl. 6.2325.000 pHit kit 6.2325.000 pHit kit na tion with organic to AB-048. Reactivate Surfactrode Wipe carefully with is recommended. Ag Titrodes also Rinse with water or is recommended. is recommended. residues, immerse Ag ring electrodes also Resistant with fine-a methanol-soaked available with Ag ethanol. Lift sleeve ring for sensor in an appro- 2S or available with Ag2S or grained sandpaper if tissue to remove any priate solvent Ag-halide coating. Ag-halide coating. response is poor. adhering contami- Do not wipe electrode. cleaning of ground- joint diaphragm. If the (for 30 min.). Testing of the nation. Unitrodes filled with sleeve ring is blocked, Condition glass electrodes according Do not use in organic c(KCl)=3 mol/L should immerse in hot water membrane in dist. to AB-305. matrices or at be stored in for a few minutes water before next temperatures >40 °C. 6.2323.000 to dissolve adhering titration. storage solution. material. Testing of the Alternative electrolyte: electrodes according For cleaning/care Spare ground-joint c(TEABr) = 0.4 mol/L to AB-305. 6.2325.000 pHit kit diaphragm for in ethylene glycol is recommended. Profitrodes (6.2320.000). 6.0255.1X0: Order no. 6.1243.020 8.109.6005EN – 2019-04 1) Electrodes with no cable and no temperature probe have plug-in head G 2) An iConnect 2.854.0010 is required to connect an iTrode to the instrument. 3) dTrodes can only be used with a digital measuring module at an OMNIS Titrator / Titration Module. 4) Electrodes with no cable and with an integrated temperature sensor have plug-in head U