916 Ti-Touch, 915 KF Ti-Touch and 917 Coulometer Compact titrator for routine analysis Technical specifications 02 916 Ti-Touch 916 Ti-Touch with 915 KF Ti-Touch 917 Coulometer with Rod stirrer magnetic stirrer Dosing element with Intelligent Exchange Max. 2 × 800 Dosino or 2 × 805 Dosimat Unit/Dosing Unit with an integrated data chip Dosing steps per cylinder content 800 Dosino: 10,000 pulses; 805 Dosimat: 20,000 pulses Operation, dialog Touch Control Incl. 802 Rod stirrer additionally 1 × 801 Magnetic stirrer Built-in magnetic stirrer, additionally 1 x 801 Magnetic stirrer or Stirrers, titration stand or 1 × 802 Rod stirrer 1 x 802 Rod stirrer or 1 x 803 KF Titration Stand or 1 × 803 KF Titration Stand Attachment of Dosimats, Dosinos, stirrers 2 MSB connectors (Metrohm Serial Bus, Daisy Chain) 1 Sample Changer (810, 814, 815) via USB 885 Compact Oven SC via Attachment of Sample Changers 885 Compact Oven SC via Remote Box (optional) Remote Box (optional) FDA Compliance YES Attachment of balances, printer, PC, Via USB Slave Port, USB/RS-232 Converter (optional) PC keyboard, barcode reader Generation of forge-proof PDF reports YES without a PC USB flash drive for saving methods, results YES and PDF reports Ethernet interface to connect to a local network for data archiving or printing on YES network printers Temperature sensor Pt1000 or NTC «iTrodes» – intelligent electrodes YES – – GLP-compliant electrode test YES – – I and U – integrated programmable pol pol YES polarizer Real-time curve display on the Touch Control (90 mm × 120 mm, high-resolution color YES display) DET Dynamic Equivalence-point Titration YES – – MET Monotonic Equivalence-point Titration YES – – SET Titration to a preset endpoint with YES – – automatic conditioning STAT (enzymatic and pH-STAT titrations) YES – – MAT Manual Titration YES – – KFT Volumetric Karl Fischer Titration – – YES – KFC Coulometric Karl Fischer Titration – – – YES BRC Coulometric Bromine Index Titration – – – YES MEAS Measuring mode for pH, U/mV, T/°C YES – – CAL Calibration with automatic buffer YES – – recognition MEAS Measuring mode for I , U , T/°C – – YES pol pol Method storage, sample data storage, YES result memory, data storage Dialog languages German, English, Spanish, French, Chinese, Italian, Portuguese, Polish, Russian, Korean, Japanese Favorites for quick method access 14 (per user) Automatic titration start – – – YES 03 Ti-Touch – the modern way to titrate «Reduce to the max» – this is the Ti-Touch concept. The compact titrator from Metrohm offers maximum performance in routine analysis in the smallest possible space: • Maximum system integration: buret, stirrer and control module in one practical unit. • Maximum data security and network integration – without a PC! - FDA Compliance: All Ti-Touch models comply with FDA-regulation 21 CFR, Part 11. - Generate forge-proof reports in PDF format and save them to a USB flash drive or to the network. - Ethernet interface for direct access to the Intranet. Method Printing on network printers, method archiving and determination data storage directly in the LIMS. - USB interface for direct connection to a printer (A4 or compact), a USB flash drive or a barcode reader. • Maximum user safety: no-touch reagent replacement thanks to patented Dosino technology. • Maximum ease of use: 14 short cut icons per user to start favorite methods at a single touch. 916 Ti-Touch – the compact titrator for potentiometric titration 04 The 916 Ti-Touch is the compact titrator designed for potentiometric titration. The instrument sup-ports all titration modes: DET (dynamic equivalence point titration), MET (monotonic equivalence point titration), SET (titration to one or two specified endpoints), STAT (enzymatic and pH-STAT titrations), and MAT (manual titration). • Save and print data, etc. – without a PC USB interface for printer, keyboard or barcode reader. Save methods and determination data directly to a USB flash drive for uploading again at a later date. • Direct access to Intranet and LIMS – without a PC Ethernet interface: direct access to the Intranet and LIMS for method archiving and data management. • Affordable automation The 810 Sample Processor enables fully automated analysis for up to 24 samples. • Plug-and-play operation All system components are recognized and registered automatically upon connection. • More efficiency thanks to 2 MSB connectors Two installed Metrohm Serial Bus (MSB) ports permit the connection of a second titration stand complete with buret, e.g. for the sequential titration of total acidity and chloride. 05 • Contact-free reagent replacement No contact with reagents thanks to the patented 800 Dosino technology. • Intelligent rod stirrer The stirrer rotational speed adapts automatically. • Incorrect results excluded All system components (electrodes, exchange units, etc.) and measurement results are monitored and mal-functions area displayed – in plain text. • tiBase titration database for perfect workflow Store determination data on a USB flash drive or in your network for direct importing from there into tiBase. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them to a USB flash drive or to the network. • Personalized touchscreen for fast method start Up to 14 methods per user can each be linked to a favorites icon. Standard methods start with a single tap on the touchscreen. 915 KF Ti-Touch – the titrator for volumetric Karl Fischer titration 06 Just as with the 916 Ti-Touch, the 915 KF Ti-Touch Karl Fischer version is also an outstanding instrument: buret, stirrer and operating module are integrated in a single, compact system unit. This is not only practical but also and in particular saves a great deal of space on the laboratory table. • Affordable automation The 810 Sample Processor enables fully automated analysis for up to 24 samples. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them to a USB flash drive or to the network. • Save and print data, etc. – without a PC USB interface for printer, keyboard or barcode reader. Save methods and determination data to a USB flash drive for uploading again at a later date. • Personalized touchscreen for fast method start Up to 14 methods per user can each be linked to a favorites icon. Standard methods start with a single tap on the touchscreen. • Plug-and-play operation All system components are recognized and registered automatically upon connection. • Access the Ethernet and LIMS – without a PC Direct access to the Intranet and LIMS for method archiving and data management. 07 • Contact-free reagent replacement Contact with KF reagents is avoided with the patented Dosino technology. The moment of replacement is freely selectable. • Keeping track thanks to KF icons KF icons show whether the instrument is still conditioning or if water determination can now be started. • tiBase titration database for perfect workflow Store determination data on a USB flash drive or in your network for direct importing from there into tiBase. • «Safety Stop» prevents the cell from overflowing The electrode test and the «Safety Stop» parameter prevent cell overflow during conditioning. If, for example, the electrode is inadvertently not properly connected or the titration cell is very humid, conditioning will be discontinued after a certain time or after a certain volume of KF reagent has been added. This feature enhances work safety in your laboratory. • Integrated pump for maximum safety Thanks to the integrated pump, the titration cell can be emptied and filled again afterwards with fresh solvent at the push of a button. 917 Coulometer – the compact titrator for coulometry 08 The 917 Coulometer is the compact titrator for coulometric Karl Fischer titration. The operating module, stirrer, and pump for reagent exchange are combined into a single, space-saving, compact instrument. • Automation is always an option Measurements can be easily automated with the 885 Compact Oven Sample Changer. • Paperless PDF reports Generate forge-proof PDF reports without a PC and save them to a USB flash drive or to the network. • Personalized touchscreen for fast method start Up to 14 methods per user can each be linked to a favorites icon. Standard methods start with a single tap on the touchscreen. • Reagent monitoring for maximum safety The reagent is continuously monitored. Once self-defined criteria (number of added samples, amount of added water, etc.) are met, the user is prompted to replace the reagent. 09 • Integrated pump for optimum convenience The integrated pump enables the titration cell to be emptied and then refilled with fresh reagent at the touch of a button. Contact with reagents is completely avoided. • Keeping track with KF icons KF icons show whether the instrument is still conditioning or if water content determination can now be started. • Automatic titration start No manual titration start required. The instrument automatically begins the titration after the sample has been added. • tiBase titration database for maximum convenience Save determination data to a USB flash drive or to a network drive, from where it can be imported directly into the tiBase database software. FDA compliance 10 All members of the Ti-Touch family now fully comply with FDA-regulation 21 CFR, Part 11. This includes: • Sophisticated user administration • Complete traceability Allocate access rights to each user in accordance with Who carried out a determination and when? What your company’s security policy. titrator was used? What alterations were made to the determination and by whom? All this is recorded • Complete Audit Trail permanently for each individual determination. The Each action performed on a Ti-Touch Titrator is stored unique traceability of the Ti-Touch titrators leaves no automatically in the Audit Trail. This means that you question unanswered. can obtain a detailed record of which employee performed what action at what point in time. Ti-Touch in the networked laboratory Network Printer USB Printer LIMS Lab PC / tiBase Shared Memory Determinations PDF reports Office PC / tiBase Stick Shared Memory USB Method pool PDF reports Neo’s 916 915 916 917 Printer USB Printer Integrate the Ti-Touch Family in your networked laboratory: automatically export PDF reports/determination files to your LIMS or into tiBase on your lab/office Computer, print on local or network printers, and share titration methods from a centralized network directory. Even data from instruments not connected to the network can be transferred via manual export to a USB memory stick. tiBase – modern titration data management 11 Manage and archive your titration data Either your Ti-Touch is directly connected to your network elec tronic signature function secures your titration data: or titration data is manually imported from a USB stick: Once a determination has been signed on both levels, it Your determinations are therefore safely archived, giving is protected against further manipulation. you full traceability of all aspects of the determinations. This software will greatly facilitate your work, because State-of-the-art connectivity – convenient data you can search for and filter determinations. exchange and reporting Data export from tiBase is easily done and such data is Straightforward reprocessing available in various formats (e.g. .csv, .slk, .xml) for fur-This is particularly helpful if you wish to correct the sam-ther processing in Microsoft Office applications. More-ple weight or use a different formula to calculate results, over, tiBase enables you to create customized reports, for example. It goes without saying that all changes that giving you the freedom to include only the specific infor-are made to a determination are recorded and that the mation you need. original determination can be restored. The two-level 810 Sample Processor 12 Automation safeguards quality results The 810 Sample Processor adds an important element throughput, it is essential to ensure that each sample is to your application – automation. Why automate your processed with the same accuracy. Only this guarantees application? Most importantly, to safeguard the quality consistent, reproducible and, above all, precise results. of your results: If you have to manage a high sample • Analyse up to 24 samples completely • Comprehensive liquid handling unattended Connect up to 3 additional burets for dosing Straightforward automation for small to medium size applications sample series • Precise and reproducible results • Minimize exposure to hazardous liquids Use the integrated membrane pump to perform Add optional external pumps for safe disposal of automated cleaning steps for better reproducibility hazardous waste solutions Work more comfortably Superior flexibility 13 Your 810 Sample Processor is controlled with utmost pre-The 810 Sample Processor comes with a built-in, space-cision. Once the methods have been saved on the easy-saving membrane pump. However, it can be upgraded to-use Ti-Touch user interface, all you have to do is place with external membrane or peristaltic pumps any time, your samples on the 810 Sample Processor and enter the if required. sample data. Your samples are then analyzed fully automatically without any further intervention required. Place all samples Evaluate results on the rack Add solvent / Clean / conditioning auxiliary solution of the electrodes Titrate / measure Dispose of The 810 offers a wide choice of sample racks for different sample beakers. Depending on the sample size between 12 and 24 beakers can be processed in a series unattended. Available racks 6.2041.310 12 × 250 mL 6.2041.320 16 × 150 mL 6.2041.340 24 × 75 mL 6.2041.370 14 × 200 mL 6.2041.380 14 × 8 oz 6.2041.470 22 × 120 mL Ordering information 14 915 KF Ti-Touch 2.915.0110 KF Ti-Touch All-inclusive package** for volumetric KF titrations 2.916.0020 916 Ti-Touch with Magnetic stirrer 916 Ti-Touch all-inclusive packages* 2.916.2010 Salt Ti-Touch* All-inclusive package for the argentometric titration of chloride, etc. 2.916.3010 Oil Ti-Touch* All-inclusive package for the nonaqueous acid-base titration of oil products 2.916.4010 Food Ti-Touch* All-inclusive package for aqueous acid-base titration in foodstuffs, etc. 917 Coulometer 2.917.0010 917 Coulometer with generator electrode with diaphragm 2.917.0110 917 Coulometer with generator electrode without diaphragm 2.917.1110 917 Coulometer with generator electrode without diaphragm and with 860 KF Thermoprep 2.917.2110 917 Coulometer with generator electrode without diaphragm and with 885 Compact Oven Sample Changer * ready-to-use all-inclusive package contains 800 Dosino, 20 mL Dosing Unit, iConnect, i-Trode, 802 Rod stirrer, tiBase Demo version and comprehensive collection of applications. ** ready-to-use all-inclusive package contains 800 Dosino, 10 mL dosing unit, electrode, accessories for safe reagent replacement and tiBase Demo version. 15 Optional accessories 2.800.0020 800 Dosino as additional buret for titration or addition of auxiliary solutions 2.805.0010 805 Dosimat as additional buret for titration or addition of auxiliary solutions 6.2061.010 Bottle holder for Dosino as expansion to a second titration stand 2.801.0040 801 Magnetic stirrer compl. 2.810.0010 810 Sample Processor 2.141.0100 USB thermal printer Neo’s 6.3026.110 Intelligent exchange unit 1 mL 6.3026.150 Intelligent exchange unit 5 mL 6.3026.210 Intelligent exchange unit 10 mL 6.3026.220 Intelligent exchange unit 20 mL 6.3026.250 Intelligent exchange unit 50 mL 6.3032.120 Intelligent dosing unit 2 mL 6.3032.150 Intelligent dosing unit 5 mL 6.3032.210 Intelligent dosing unit 10 mL 6.3032.220 Intelligent dosing unit 20 mL 6.3032.250 Intelligent dosing unit 50 mL 6.2148.010 Remote Box MSB 6.2148.050 USB/RS-232 Converter 6.2151.030 Cable USB A – USB B / 0.6 m www.metrohm.com G, CH-9100 Herisau ohm A witzerland by Metr , printed in S SW -06 Subject to modifications Layout by Ecknauer+Schoch A 8.916.5003EN – 2017