Arbin Instruments The BT11-HSP (High Speed Pulse with 1 microcontrol er and 1 DC power supply per channel) is designed to perform sub-mil isecond pulses on bat eries or super capacitors, which are common in wireless or telecommunication applications. Arbin’s pulse capability covers a broad range of sub-mil isecond communication profiles, which can handle multi-stage pulses as fast as 100 microseconds per stage and up to 10 stages per pulse. The pulses have a maximum length of 2700 seconds. Model Voltage Power The BT11-HSP integrates the digital control er and power supply circuitry in BT11-HSP-25 0V to 5V 5A/1A/100mA a smal footprint as a powerful and completely independent channel. The BT11-HSP-5 0 to 10V 500mA/50mA/1mA channel independence al ows users to perform channel calibration while BT11-HSP-1 -10 to 10V 100mA/50mA/1mA al owing other channels to continue uninterrupted testing. Each channel of the system functions as an independent potentiostat/ galvanostat. Commonly used charge/discharge functions such as ramps, staircases and constant current, voltage, power, and load functions may be used independently on al channels at the same time. The BT11-HSP al ows the user to run independent pulse and simulation profiles on each channel simultaneously. The circuit is a bipolar design that af ords tremendous flexibility by ensuring cross-zero linearity with no switching time. Our MITS Pro Software further enhances al these capabilities, which according to customer feedback is a step above al other software in the industry. ■ Multiple, independent channels for pulse or simulation ■ Minimum pulse stage width of 100μs ■ Rise times as fast as 10μs ■ Ability to calibrate individual channels without interrupting testing on other channels ■ Simultaneous pulse generation and data logging ■ Other custom user-defined pulse profiles with 2-10 stages ■ Multiple current ranges per channel available ■ Windows 7 based software ■ Many input auxiliaries available such as temperature and/or voltage ■ Voltage clamp to help protect from over or under charge or discharge BT11-HSP +1 979 690 2751 www.arbin.com Arbin Instruments Model Number: BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 ■ Lithium Bat ery Testing ■ Single Cel Recharge-ability ■ Testing application for cel ular phones and other smart communication devices ■ Cover various standard pulse-testing applications such as GSM, CDMA, iDEN, GPRS, etc. MODEL NUMBER BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 Number of Micro Control er (MC) One Micro Control er per main channel Voltage Range (min/max) 0V to 5V 0V to 10V (-10V) to 10V ± 5mV ± 15mV ± 10mV Accuracy of Voltage Control & Reading 0.05% Ful Scale Accuracy 0.05% Ful Scale Accuracy 0.05% Ful Scale Accuracy Minimum V at Maximum Current 0V @ 5A 0V @ 500mA (-10V) @ 100mA Voltage Measurements Input ~ 100GΩ Impedance High: 5 ± 5mA High: 500mA ± 500uA High: 100mA ± 100uA Current Ranges (0.05% FSR) Medium: 1 ± 1mA Medium: 50 Medium: 50mA ± 50uA mA ± 50uA Low: 100mA ± 100uA Low: 1mA ± 1uA Low: 1mA ± 1uA Maximum Continuous Power Output 25W 5W 1W per channel Current Rise Time1 10uS Current and Voltage Resolution 16 Bit Voltage Clamp2 Individual / Channel Based Voltage Clamp 5U Chassis 4 channels 8 channels 8 channels 12.5” X 25” X 10.5” 110VAC-10A with 20A circuit breaker 16 channels 11U Chassis 15” X 30” X 25” 110VAC with 110VAC with 30A circuit breaker 20A circuit breaker Standard 6ft. Cables with al igator clips. Arbin also provides bat ery holder system on the side of the Connection for bat eries chassis to provide easy engagement system to the bat ery tester. Connection to Computer TCP-IP Ventilation Method Air-cooled, front-to-rear airflow Room Operating Temperature 10 to 35 degrees C 1 Time required for current output to get from 10% to 90% of requested value. 2 For BT11-HSP, the voltage clamp accuracy tolerance is 0.2% FSR. BT11-HSP +1 979 690 2751 www.arbin.com Arbin Instruments Model Number: BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 Pulse Characteristics Pulse Independency One Pulse Profile per Channel Maximum Total Pulse Stage (n)3 10 Minimum Pulse Stage Width 100 microsecond Pulse Stage Increment Width 20 microsecond Maximum Total Pulse Length (T) 2700 seconds Control Type Current Standard Pulse Data Logging Characteristics Data Logging All channels can log simultaneously Maximum number of logged data points per stage 2 samplings: near the beginning and end of each stage Standard pulse data logging interval 1 second4 Burst Pulse Mode Data Logging Characteristics Data Logging All channels can log simultaneously Maximum Total Pulse Stage (n) 10 Maximum number points logged per stage 298 Maximum number points logged per pulse 300 Minimum logging interval range 50uS Pulse Stage Increment Width 10uS Interval between Pulses 1 second 3 Pulse must contain at least two stages with minimum pulse width. 4 Software wil always log first and last data points. BT11-HSP +1 979 690 2751 www.arbin.com Arbin Instruments Model Number: BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 Burst mode operation al ows user to log data at a very high rate for a maximum time of 500 mil iseconds. Up to 300 points per pulse can be logged across a maximum of 10 stages per single pulse. This application can be useful in instances where fast data logging is required to catch voltage and/or current data during a transition. By capturing more data, the pulse profile can be more accurately defined, especial y during the charge/discharge transition period (see software screen below). This helps to identify transition in the charge/discharge process of the objects being tested. Single Pulse Profile—Standard Data Logging Single Pulse Profile—Pulse Burst Data Logging 2 data points per stage Up to 300 data points per pulse Current (A) Outputs constant current to the cel or bat ery at the value specified. Positive current refers to charge, and negative current refers to discharge. Voltage (V) Outputs constant voltage to the cel or bat ery at the value specified C-Rate C-Rate is common method for indicating the discharge as wel as the charge current of a bat ery. It can be expressed as I=M*C where I=current A; C=bat ery capacity; M is the C-rate value Rest The bat ery is disconnected from the charge/discharge circuit but remains connected to the voltage measurement circuit to enable open-circuit voltage measurement Power (W) Outputs constant power to the cel of bat ery at the value specified. This is accomplished by iteratively measuring the bat ery voltage and calculating the current necessary according to Ohm’s law in order to achieve the power level set by the user. Each time the channel is sampled, the calculation is performed al owing the current to quickly stabilize at the desired BT11-HSP +1 979 690 2751 www.arbin.com Arbin Instruments Model Number: BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 Load (Ohm) Applies a constant resistance load to the bat ery at the value specified. Set Variable(s) Change test related variables including channel capacity, energy, and al test counter variables Current Ramp Generates a current ramp with a positive scan rate for increasing current and a negative scan rate to generate decreasing current ramp Voltage Ramp Generates a voltage ramp with a positive scan rate that increases the voltage ramp, and negative scan rate generates decreasing voltage ramp Current Staircase Generates a current staircase with increasing current, and negative decreasing current staircase with adjustable step amplitude Voltage Staircase Positive dV/stair generates increasing voltage staircase, and negative dV/stair generates decreasing voltage staircase Current Pulse Applies a predefined or custom current profile to the cel or bat ery pack under test Current and Power Simulation Non-standard time-domain functions may be input from external sources such as ASCI data Current & Power Simulation Non-standard time-domain functions may be input ed from external sources such as ASCI streams and used as control parameters for repetitive tests data streams and used as control parameters for repetitive tests. DC Internal Resistance This function applies a 10-pulse train with 100µs pulse width of the specified magnitude Internal Resistance This function applies a 10-pulse train with 1mS pulse width of the specified magnitude fol owing a constant-current charge or discharge step fol owing a constant-current charge or discharge step. CC-CV Combine constant current control and constant voltage control into one step “CC-CV” End Conditions Time, Voltage, Current, Capacity, Energy, ΔV, DV/dt, formula, meta-variables, and other combinations Network Capabilities Provide TCP/IP access for networking Data Result File Imported into Microsoft Excel; Arbin’s Excel Data Pro macro included for easy data manipulation Data File Content Channel data: test time, step time, voltage, current, capacity, energy, first/second derivative of I or V, auxiliary input data (optional). Statistical data: Cycle #, Cycle Capacity/Energy, Maximum voltage, etc BT11-HSP +1 979 690 2751 www.arbin.com Arbin Instruments Model Number: BT11-HSP-25 BT11-HSP-5 BT11-HSP-1 Arbin Instruments provides a wide variety of auxiliary modules for expanding the capability of the main I/V control circuitry. Input Modules: Auxiliary inputs can be used to record desired data as wel as to terminate or regulate charge and discharge processes based upon measured conditions. Selectable inputs are of V (voltage), T (temperature), and P (pressure). Input / Output Modules Digital I/O is an integrated peripheral on/of control. The output commonly is used to control valves and switches. The input al ows external control signal to control testing procedure. Control Modules: Arbin provides control modules for auto-calibration, Smart Bat-tery Testing, External Charger, Temperature Chamber interface and AC impedance measurement. For more information please visit: www.arbin.com/products/accessories/auxiliaries.htm *Auxiliaries are provided in a separate chassis, controlled by the same PC as the test station. Several safety provisions are provided in every Arbin system. There are multiple levels of fusing provided inside the system for further protection at the channel/board and power supply levels. The software also has several safety functions with which the user can avoid over charging the cel s, over discharging, overheating, etc. Smart UPS: This option uses a very smal Smart UPS to back up power to the computer only. This al ows the user to enable auto resume options to al of specific channels after a stop due to power interruption. Provision is provided for the user to intervene if they so desire before the channels resume. This is an essential component for any user with an unreliable power source unless the whole facility is on backup power. BT11-HSP +1 979 690 2751 www.arbin.com