MILESTONE H E L P I N G C H E M I S T S SAVE TIME GO DIRECT FOR MERCURY ANALYSIS DMA-80 Direct Mercury Analyzer SIMPLIFY YOUR TOTAL M E R C U R Y D E T E R M I N A T I O N INDUSTRY-LEADING GO DIRECT ! PERFORMANCE The Milestone DMA-80 has been at the forefront of direct total mercury analysis for almost two decades. The challenges in mercury determination are well known to analysts who often have to face a number of issues due to either the tedious sample preparation process or the analysis step. The latter, even with the UNPARALLELED latest generation of ICP-MS or cold vapor systems, EASE OF USE may create a memory effect even after long cleaning cycles. The DMA-80 can analyze any matrix (solid, liquid or gas) without any pre-treatment or chemical additions in as few as 6 minutes. We are and have been the benchmark for direct mercury determination in most industries: environmental, food, energy, cement, cosmetics, agriculture, mining, and petrochemical. With thousands of DMA-80s installed in over 80 countries, HIGH PRODUCTIVITY AND Milestone has a wealth of experience and knowledge EFFICIENCY regarding direct mercury determination, ensuring your lab state-of-the-art technology and premium customer support. LOW RUNNING AND MAINTENANCE COSTS IMPRESSIVE APPLICATION FLEXIBILITY Detector Detector Drying and Filter Filter decomposition furnace Built-in autosampler Catalyst furnace Gold amalgamator Cuvette with multiple cells Sample beam Sample beam Hg lamp Reference beam Filter Sample boat Detector DMA-80 evo schematics SUPERIOR PERFORMANCE EVEN AT THE PPT LEVEL The analysis process starts by weighing sample into a boat and IMPROVED then running it through thermal decomposition under air or oxygen flow. All mercury and residual combustion products then flow into the catalyst section. Here, interferences are removed and mercury D E S I G N species are reduced and trapped on a gold amalgamator with FROM THE INSIDE OUT subsequent release into multiple measuring cells positioned along the spectrophotometer's optical path. The DMA-80 evo double beam dramatically increases the signal-to-noise ratio, which greatly improves the quantification limit, enabling accurate and precise mercury determination even at the ppt level. This increased signal stability improves the reproducibility and reliability of analysis even at low concentrations. With the DMA-80 evo, you get the right results the first time, every time. FULL MERCURY RECOVERY The DMA-80 evo is equipped with an advanced catalyst tube and gold amalgamator to provide high-end performance, full mercury conversion, interference removal, and fast mercury release. These components allow the DMA-80 evo to deliver fast and accurate results in a single measurement, providing symmetrical peaks and avoiding mercury overestimation or underestimation. Sample Amount Concentration Blank - 0.0001 µg/L Water Sample 1st 0.5 mL 0.105 µg/L Water Sample 2nd 0.5 mL 0.108 µg/L Water Sample 3rd 0.5 mL 0.109 µg/L Water Sample 4th 0.5 mL 0.106 µg/L Water Sample 5th 0.5 mL 0.105 µg/L 0.1069 µg/L Average - : rel 1.76% Example of reproducibility of the DMA-80 evo at very low mercury concentrations D E L I V E R I N G Direct mercury analysis is inherently easier, simplifying PERFORMANCE WITH mercury determination to its roots. The DMA-80 evo’s many features ensure superior ease of use coupled EASY TO USE with greater accuracy and precision. T E C H N O L O G Y A SINGLE LONG-LASTING CALIBRATION FOR ALL MATRICES A single calibration, completed using liquid or solid reference materials, suits a large variety of samples for a wide concentration range - from ppm to ppt. Moreover, because of both system stability and long working-life of the catalyst tube and gold amalgamator, calibration of the DMA-80 evo offers long-term reliability. Daily calibrations often required by conventional instrumentation are not necessary. Certified material Certified (µg/kg) DMA-80 (µg/kg) NIST 1568a Rice Flour 5.8 ± 0.5 5.9 ± 0.2 BCR-150 Skim Milk Powder 7.7 - 11.1 9.2 ± 0.2 NIST 1630a Coal 93.8 ± 3.7 93.4 ± 2.4 NIST 1633b Fly Ash 141 ± 19 149 ± 2 BCR-61 Aquatic Plant 210 ± 250 221 ± 3 GSD-10 Stream Sediment 280 ± 40 270 ± 15 BCR-422 Cod Muscle 543 - 575 558 ± 8 Results of various certified reference materials using the same calibration ENHANCED SOFTWARE CAPABILITIES AND CONTROL The intuitive DMA-80 evo software, EasyCONTROL, available on both Method Calibration Measure System Terminal Settings Service Pos Samplename Amount State Height Hg [ng] [µg/Kg] Cal Factor ∑ Group Panel Users Update LAN Trail the dedicated terminal and on PC, 2 1.0000g cl 0.0001 0.0001 0.0001 0.0990 (2) 17.10.16 10:11 17.10.16 10:17 All System Access Errors Application 3 1.0000g cl 0.0002 0.0004 0.0004 0.0990 (3) 17.10.16 10:11 17.10.16 10:23 4 1.0000g boat 0.0298 0.0505 0.0505 0.0990 Time Changes (4) 17.10.16 10:58 17.10.16 10:58 5 1.0000g boat 0.0362 0.0614 0.0614 0.0990 (5) 17.10.16 10:58 17.10.16 11:03 10.07.18 09:58:03 Device error: Light barrier error 6 1.0000g boat 0.0257 0.0434 0.0434 0.0990 (6) 17.10.16 10:58 17.10.16 11:08 10.07.18 10:04:22 Software update: Dma80-660-03-D-11.exe660 includes the most advanced features 7 1.0000g boat 0.0280 0.0474 0.0474 0.0990 (7) 17.10.16 10:58 17.10.16 11:14 10.07.18 10:04:30 Login (Service) 8 1.0000g boat 0.0526 0.0896 0.0896 0.0990 (8) 17.10.16 10:58 17.10.16 11:19 1 0.0750g 10.07.18 10:14:35 Device error: Light barrier error DORM-3 0.0251 28.0822 374.4287 1.0000 (9) 1 17.10.16 11:36 17.10.16 11:43 2 0.0770g DORM-3. 0.0263 29.4348 382.2704 1.0000 1 10.07.18 10:29:49 Auto-Logout (10) 17.10.16 11:36 17.10.16 11:48 ∑ 3 0.0670g DORM-3. 0.0226 25.2671 377.1208 1.0000 (11) ∑ 1 10.07.18 11:18:54 Login Admin (Administrator) to simplify analysis reporting: LIMS 17.10.16 11:36 17.10.16 11:54 4 0.0730g DORM-3. 0.0249 27.8568 381.5999 1.0000 (12) 1 17.10.16 11:36 ∑ 17.10.16 11:59 10.07.18 11:28:54 Auto-Logout 5 0.0660g DORM-3. 0.0224 25.0421 379.4252 1.0000 (13) 1 17.10.16 11:37 ∑ 17.10.16 12:04 10.07.18 11:31:30 Login Admin (Administrator) 6 0.0780g DORM-3. 0.0269 30.1115 386.0449 1.0000 ∑ 1 (14) 17.10.16 13:49 17.10.16 13:58 10.07.18 11:41:39 Auto-Logout 7 0.0670g DORM-3. 0.0244 27.2935 407.3661 1.0000 (15) 17.10.16 13:50 17.10.16 14:03 10.07.18 11:41:54 Login Admin (Administrator) connection, data handling, data Sample Links Signal Result 10.07.18 11:44:34 Device error: Light barrier error 10.07.18 12:42:24 Login Admin (Administrator) m= 244.2604 µg/Kg 1 11.07.18 11:57:07 Login (Service) σabs= 189.1387 µg/Kg Filter Usage import/export, and an audit trail in σrel= 77.43 % M I L E S TO N E www.milestonesrl.com M I L E S TO N E www.milestonesrl.com compliance with 21 CFR part 11. Our H E L P I N G H E L P I N G C H E M I S T S C H E M I S T S data reprocessing feature prevents the need to re-run a specific sample. Statistics on the DMA-80 evo software Complete audit trail in full compliance with 21 CFR part 11 FORGET MEMORY EFFECT The memory effect in mercury analysis is widely recognized as one of the most common challenges that analytical chemists MILESTONE face. Milestone’s DMA-80 evo fully overcomes it with a revolutionary feature: Autoblank. This, along with the other C O N N E C T high-performance components of the system, eliminates 30 YEARS OF EXPERIENCE overestimation and ensures low blanks, thus enhancing user confidence in the data collected, while still ensuring high AT YOUR FINGERTIPS productivity. Included with the DMA-80 evo is a unique web-based application: 1. SEABASS Milestone Connect. This app allows Method Calibration Measure System Pos Samplename Absorbance [A] 12 ^0= 1.4498 ^1= 1.3134 1.00 Direct mercury analysis of a you to become a part of the Milestone (711) blank 20 0.90 (712) Fi sh (Seabass) - 0.80 auto BV (1) W (716) 0,5= 2.35 s 0.70 W - 0,5= 2.90 s auto BV (2) (717) seabass sample. community and gain exclusive access 0.60 13 blank (713) 0.50 23 Ref. Material CRM 0.40 (714) - auto BV (1) 0.30 (718) to a robust library of information: lists 14 blank 0.20 (715) ^2= 0.0939 15 0.10 blank W0,5= 4.45 s Hg: 1239.66 µg/kg (719) 0.00 16 PD PD blank (720) 5 10 15 20 5 10 15 20 25 30 35 40 t0= 6.25 s t1= 7.90 s t2= 18.60 s Time [s] of parts, technical notes, user manuals, Sample Links Signal Result Total time 00:00:00 video tutorials, continuously updated 00:00:00 M I L E S TO N E www.milestonesrl.com application notes and all relevant H E L P I N G C H E M I S T S scientific articles. Milestone Connect also extends instrument control to your smartphone, tablet or PC, allowing remote monitoring of the system. With Milestone Connect you have instant 2. AUTOBLANK Method Calibration Measure System Pos Samplename Absorbance [A] 12 When the Hg concentration access to 24/7 support. 1.00 (711) blank 20 0.90 (712) Fish (Seabass) - 0.80 auto BV (1) (716) 0.70 - auto BV (2) (717) is above the set value in 0.60 13 blank (713) 0.50 23 Ref. Material CRM 0.40 (714) - auto BV (1) 0.30 (718) the Autoblank, the system 14 blank 0.20 (715) 15 0.10 blank ^0= 0.0358 ^1= 0.0154 (719) W0,5= 1.25 s W0,5= 2.05 s 0.00 16 PD PD blank (720) 5 10 15 20 5 10 15 20 25 30 35 40 t0= 6.35 s t1= 8.25 s Time [s] automatically starts a blank Sample Links Signal Result Total time 00:00:00 cycle. 00:00:00 M I L E S TO N E www.milestonesrl.com H E L P I N G C H E M I S T S 3. LOBSTER Method Calibration Measure System Pos Samplename Absorbance [A] HEPATOPANCREAS (TORT-3) 12 1.00 (711) blank ^0= 0.8893 20 0.90 (712) Fi sh (Seabass) - 0.80 milestone auto BV (1) (716) 0.70 - Thanks to the Autoblank feature auto BV (2) (717) 0.60 13 ^1= 0.5132 blank (713) 0.50 W 23 0,5= 1.45 s Ref. Material CRM 0.40 (714) - auto BV (1) 0.30 (718) W0,5= 2.05 s the next sample is analyzed with 14 blank 0.20 (715) ^2= 0.0118 15 0.10 blank W (719) 0,5= 4.50 s 0.00 nnect 16 PD PD blank (720) 5 10 15 20 5 10 15 20 25 30 35 40 t0= 6.20 s t1= 7.95 s t2= 19.05 s Time [s] great precision and accuracy, Sample Links Signal Result Total time 00:00:00 avoiding overestimation. 00:00:00 M I L E S TO N E www.milestonesrl.com H E L P I N G Hg: 287.65 µg/kg C H E M I S T S Certified value: 292 ± 22 µg/kg M A X I M I Z E LAB PRODUCTIVITY AND RETURN ON INVESTMENT THE FASTEST PATH TO MERCURY DETERMINATION The DMA-80 evo is equipped with a 40-position autosampler suitable for solid, liquid and gas samples. Samples are directly weighed in a boat, the weight is recorded by the EasyCONTROL software, then the quartz or metal boat is placed into the 40-position autosampler to begin analysis. This process is completed in as few as 5 minutes from weighing to results. Method development and sample preparation are unnecessary. The DMA-80 evo runs unattended, offers a quick turnaround time and has become a necessity for mercury determination in many labs over a wide range of applications. Sample weighing Sample boat is placed In 5 minutes the sample into the boat into the autosampler is analyzed LOW RUNNING COSTS, SUPERIOR ROI A streamlined workflow is essential in a modern lab. The DMA-80 evo accommodates those needs by providing an easy-to-maintain system with a low running cost. The advanced components of the DMA-80 evo are synonymous with reliability, ensuring the same quality over and over again. The DMA-80 evo runs perfectly with either compressed air or oxygen as a carrier, providing additional savings to your lab without compromising on performance. DMA-80 CV-AAS/ ICP-MS Sample type Solid, liquid and gas Aqueous Working range From ppt to ppm ppb Sample preparation Not required Required Memory effect Very low Medium to high Daily calibration Not required Required Matrix effect None Medium/High Productivity Very high Low/Medium Running cost Low Medium/High Comparison between different technologies for mercury determination THE PERFECT TOOL FOR ANY APPLICATION GO DIRECT FOR ANY SAMPLE Since its introduction, the DMA-80 evo has seamlessly integrated into a wide range of applications and industries. It is used for mercury determination in environmental applications such as soil, Environmental Food/Fish Power plant/Coal wastewater, sediment, and waste testing. It has also been adopted into the food industry, where fish testing is the primary application. The DMA-80 evo combines high performance, impressive productivity and ease of use in a single solution. Cement/Mining Clinical/Biological Petrochemical OFFICIAL METHODS COMPLIANCE The DMA-80 evo is fully compliant with multiple official methods such as the US EPA method 7473, developed with the DMA-80 evo, (Mercury in solids and solutions by thermal decomposition, amalgamation, and atomic absorption spectrophotometry), the ASTM method D-6722-01 (Total mercury in coal and coal combustion residues) and ASTM method D-7623-10 (Total mercury in crude oil). Concentration Certified Concentration Certified Sample Sample DMA-80 (mg/kg) (mg/kg) DMA-80 (mg/kg) (mg/kg) NIST 1633b 0.142 0.14 ± 0.02 BCR 277R 0.125 0.128 ± 0.017 NIST 1633b 0.142 0.14 ± 0.02 BCR 277R 0.122 0.128 ± 0.017 NIST 1633b 0.139 0.14 ± 0.02 BCR 277R 0.123 0.128 ± 0.017 NIST 1633b 0.135 0.14 ± 0.02 BCR 277R 0.127 0.128 ± 0.017 NIST 1633b 0.140 0.14 ± 0.02 BCR 277R 0.127 0.128 ± 0.017 NIST 1633b, Constituent Elements BCR 277R, Estuarine Sediment Certified Material in Coal Fly Ash Certified Material RSD: 1.83% - Mean: 0.124 mg/Kg - SD: 0.0023 RSD: 2.06% - Mean: 0.139 mg/Kg - SD: 0.028 MILESTONE Established in 1988, Milestone is headquartered in Italy and has offices in Germany, Switzerland, the Unites States, China, HELPING CHEMISTS Japan and Korea. We operate worldwide through a network of over 100 exclusive distributors, all providing our customers premium application and service support. Milestone’s mission is to help chemists by offering them the most advanced instrumentation for sample preparation and direct mercury analysis in the world. Our industry-leading technology, in combination with fast, responsive service and applications support, allows Milestone to support our goal of providing you the highest return on investment possible. ADDITIONAL MILESTONE SOLUTIONS ETHOS UP ultraWAVE Clean Chemistry ETHOS X High Performance The Game Changer in Acid Purification Advanced Microwave Microwave Digestion Microwave Digestion and Acid Steam Extraction System System Cleaning Systems for Environmental Applications WWW.MILESTONESRL.COM MILESTONE MILESTONE Srl - Via Fatebenefratelli, 1/5 - 24010 Sorisole (BG) - Italy Tel: +39 035 573857 - Fax: +39 035 575498 www.milestonesrl.com - email: analytical@milestonesrl.com MILESTONE INC. - 25 Controls Drive - Shelton, CT 06484 - USA Tel: (203) 925-4240 - Toll-free: (866) 995-5100 - Fax: (203) 925-4241 www.milestonesci.com - email: mwave@milestonesci.com H E L P I N G C H E M I S T S MILESTONE GENERAL K.K. - KSP, 3-2-1, Sakado - Takatsu-Ku, Kawasaki 213-0012 - Japan - Tel: +81 (0)44 850 3811 - Fax: +81 (0)44 819 3036 UNI EN ISO 9001: 2008 www.milestone-general.com - email: info@milestone-general.com CERTIFIED MLS GmbH - Auenweg 37 D-88299 Leutkirch im Allgau - Germany Tel: +49 (0)7561 9818-0 - Fax: +49 (0)7561 9818-12 T261EN-004 • 2019-10 www.mls-mikrowellen.de - email: mws@mls-mikrowellen.de CA