General Catalogue AIR 2014 Air humidity and temperature measurement instruments for Heating Ventilation Air conditioning Process control Manufacturer : 0 .0 Novasina AG 701 Neuheimstrasse 12, CH-8853 Lachen, Switzerland Telephone +41 55 642 67 67 Fax +41 55 642 67 70 . 004 www.novasina.com oc E-Mail : info@novasina.ch D www.novasina.com Air humidity & temperature measurement instruments Table of contents Hygro Mate ................................................................................................................................ 3 Hygro Mate handheld ............................................................................................................................................ 4 Hygro Mate accessories ........................................................................................................................................ 4 Spare parts .......................................................................................................................................................... 5 Data logger systems ................................................................................................................ 6 Hygro Guard 30 / Cima Log 30 / Data Log 30 ......................................................................................................... 7 Accessories for data logger systems.................................................................................................................... 7 Options ................................................................................................................................................................. 8 Installation example .............................................................................................................................................. 8 Hygro Maxx.............................................................................................................................. 10 Hygro Maxx R / S / M .......................................................................................................................................... 11 Stat Maxx R / S / M.............................................................................................................................................. 12 Accessories for HygroMaxx & StatMaxx ............................................................................................................ 14 Spare parts for HygroMaxx & StatMaxx ............................................................................................................. 15 Optionals for HygroMaxx & StatMaxx ................................................................................................................ 16 TempMaxx .............................................................................................................................. 17 Temp Maxx .......................................................................................................................................................... 18 Accessories ........................................................................................................................................................ 18 Optionals ............................................................................................................................................................ 20 Spare parts ......................................................................................................................................................... 20 Hygro Dat 100 .......................................................................................................................... 21 Hygro Dat 100 ..................................................................................................................................................... 22 E-sensors ........................................................................................................................................................... 23 C-sensors ........................................................................................................................................................... 24 HIA/HIC accessories .......................................................................................................................................... 25 HIS/HICS/HICH accessories .............................................................................................................................. 27 Spare parts ......................................................................................................................................................... 30 CIC-Touch touchscreen display ........................................................................................... 32 Product overview RH/T transmitters .................................................................................... 33 Product overview data loggers / handhelds ........................................................................ 34 Doc. 004701.00 General catalogue AIR 2014 page 2 / 34 Handheld line - humidity / temperature / dew point Quality at an affordable price HygroMate A cost-optimized, precise hand-held instrument for measuring the relative humidity and temperature in rooms and ventilation systems. The large, backlit liquid crystal display permits optimal readout of the measurements at all times. The optimal handheld instrument for the service technician, for those installing climate control systems and for process control. It is also well-suited to quality control applications in the foodstuff, pharmaceutical chemical, engineering and electronic industries. Relative humidity : 0....95% rh (non-condensing) Temperature : -20...50°C Sensor & measurement range 0...50°C Electronics, power & display Precision : +/- 2% rh 5...90% rh +/- 0.3°C 0...40°C, otherwise +/-0.5°C Measurement hysteresis: approx. 1....1.5%rh (capacitive measurement cell) Resolution : 0.1..0.2°C / 0.1…0.2 % rh Communication : Large area LC display with LED back-lighting No digital/analogue interfaces Display functions : Min / Max value storage, average computation Hold measurement value storage Time and Date, Auto Off function Temperature display, °C or °F Humidity display with Mollier diagram conversion functions : • Relative humidity in % rh • Dew point temperature in °C or °F • Mixing proportion in g/m3 Mobile measurement of air temperature and humidity Measurement instrument HygroMate: Economical, fast, flexible, robust Dimensions : 145x85x37mm Who does not instantly want to know how hot, cold and humid it is? The new Weight : ca. 400 g Power : 4 x 1.5V Hygro Mate measurement instrument satisfies these wishes in almost any place alkaline batteries in the simplest way. It is a professional instrument for daily use, incorporating well-proven capacitive humidity measurement technology. The Hygro Mate is a Humidity measurement: perfect addition to Novasina’s palette of hand-held instruments. A real Capacitive humidity measurement cell Range : 0...95% rh alternative where extremely high precisions are not necessarily required (for non condensing most standard environmental applications). Precision : +/- 2.0%rh 5...90% rh Measurement hysteresis : ~ 1...1.5% rh The innovative Thumbwheel sets new standards of user-friendliness. This Speed : T90 < 10 sec. complements the ergonomic, robust, anti-slip dual-colour case design and the Temperature measurement: additional sensor-protecting filter system. The instrument can be checked at Precise NTC resistance any time and, if necessary, calibrated at one or two values using the well-Range : -20....50°C known Novasina SAL-SC check salt standards. Precision : +/- 0.3°C (0...40°C) otherwise +/- 0.5°C The new low-power processor technology with integrated climate computer and Auto OFF functions guarantees a long battery life. The display is Attention: The electronics, power and display should only be used in the switchable from International to US units. Further functions, Dew point and temperature range 0...50°C . Water Content in g/m3 help the expert to make the correct on-the-spot decisions. Sensor Checks SAL-SC: Humidity standards based on saturated salt solutions in plastic cylinders with a moisture permeable membrane. Applications: Values: 11%, 33%, 53%, 75%, 90% rh • Heating, ventilation and air conditioning: monitoring and service • Space checks in warehouses, libraries, food storage areas A “CH” adapter • Air measurements in buildings (offices, auditoria, lecture halls) (reduction ring) is required for use of • Pharmaceutical production, chemical, biological and foodstuff the SAL-SC checks. i Doc. 004701.00 General catalogue AIR 2014 page 3 / 34 HygroMate instrument / accessories HygroMate measurement instrument HygroMate hand measurement The instrument consists of: instrument Integrated electronics in an ergonomically formed plastic casing on The Hygro Mate hand-held measurement instrument is which is mounted a capacitive sensor system. delivered with a set of alkaline batteries, a metal web - Chrome plated sensor protection protection filter and an English/German user manual in system with a fine mesh metal filter. a protective cardboard package. A certificate - 4 pcs 1.5V LR 6 AA alkaline batteries documenting a factory 2-point calibration is included. - User manual (English/German) - Factory certificate with 2 humidity calibration values. - Protective cardboard package 111 8903 -> The instrument is thus ready to use. Hy groMate Weight : 400 g HygroMate accessories Table or wall holder Table or wall holder: An ideal support when wall-mounting of the Hygro Mate Dimensions : 80 x 102mm is required. Can be used as a table support by simply Weight : 85 g bending out a metal flap. Material : Stainless steel type X5CrNi1810 111 8929 Holder Protective bag for the HygroMate The protective bag comprises: We recommend that the Hygro Mate measurement Dimensions : 250 x 200 x 40mm instrument be stored, used and transported in this Weight : 185 g (empty) durable, practical, protective bag. It provides protection Material : 2 Padded textile for the instrument and includes space for accessories side pockets such as SAL-SC checks etc.. It can be carried on the for 2 SAL-SC checks shoulder or attached to a belt using the loops and their containers 111 8957 Soft bag provided. Velcro strips are provided to prevent objects falling out of the bag. Protective case for the HygroMate The protective case comprises: The Hygro Mate can also be stored and transported in Dimensions : 320 x 350 x 60mm Weight : 240 g a strong plastic case. This provides more protection (empty) Material : Polycarbonate than the above bag, but needs more space. Space for the appropriate accessories is also provided. 111 8958 Carrying case Sensor-Checks SAL-SC (rh standards) Humidity values in the temperature range 15° .... 30°C: Humidity standards based on saturated salt solutions 11.3 ..... 11.3% rF / 15....30°C in plastic cylinders with moisture permeable 33.3 ..... 32.4% rF / 15....30°C membranes. Each salt is delivered in a well-sealed 55.9 ..... 51.4% rF / 15....30°C box. Sensor Checks SC are obtainable for the 60.7 ..... 56.0% rF / 15....30°C following values (at 25°C) : 75.6 ..... 75.1% rF / 15....30°C 85.9 ..... 83.6% rF / 15....30°C 111 0885 -> SAL-SC 11 11.3 % rh colour white 75.3 % rh colour purple 90.9 ..... 89.9% rF / 15....30°C 111 0855 97.9 ..... 97.0% rF / 15....30°C -> SAL-SC 33 32.8 % rh colour blue 84.3 % rh colour white 111 0857 -> SAL-SC 53 52.9 % rh colour green 90.1 % rh colour white 260 0219 -> SAL-SC 58 57.6 % rh colour white 97.3 % rh colour yellow The precision corresponds to the 111 0859 -> SAL-SC 75 Greenspan Report 1977 251 8965 typically +/- 0.3 % rh -> SAL-SC 84 Important: please consult the operation manual of 111 0896 -> SAL-SC 90 your instrument to see which points can be calibrated. Weight : 90 g 251 8966 -> SAL-SC 97 Other SAL-SC can be used for verification. Doc. 004701.00 General catalogue AIR 2014 page 4 / 34 HygroMate - accessories / spare parts Set with 5 Sensor-Checks SAL-SC Case with all 5 Sensor Checks from 11 to 90%rh: Humidity standards based on saturated salt solutions Humidity values in the temperature in plastic cylinders with moisture permeable range 15°... 30°C : membranes. Each salt is delivered in a well-sealed 11.3 ..... 11.3% rF / 15....30°C box. Sensor Checks SAL-SC are obtainable for the 33.3 ..... 32.4% rF / 15....30°C following values (at 25°C) : 55.9 ..... 51.4% rF / 15....30°C 11.3 % rh colour white 75.6 ..... 75.1% rF / 15....30°C 32.8 % rh colour blue 90.9 ..... 89.9% rF / 15....30°C 52.9 % rh colour green The precision corresponds to the 75.3 % rh colour purple Greenspan Report 1977 111 7847 Check set (complete) 90.1 % rh colour white typically +/- 0.3 % rh 111 7841 Empty casing Weight : 900 g SAL-SC Sensor check adapter CH CH adapter to SAL-SC salts for sensors with diameter 13 mm: for sensors with diameter 13 mm This adapter is needed for calibration of a system with Dimensions : 30 x 13 mm sensor diameter 13 mm. It ensures an airtight fixation Material : Polycarbonate, of a SAL-SC check to the sensor top (measurement rubber cell area). It reduces the diameter of 20 mm to 13 mm Weight : 5 g and ensures an airtight seal. 110 7345 Adapter CH -> The adapter should be first mounted on the sensor top and then putted the SAL-SC check on it. Both seals should be carefully checked, leaks will bias the calibration. Sintered filter for the HygroMate Sintered filter system: For higher protection against particles, dust and mechanical stress Dimensions : 34 x 13 mm A robust metallic filter made of sintered stainless steel. Material : Sintered stainless Provides active protection for the sensor system steel Response time : T50 ca. 30 sec against particles larger than 10um. Weight : 30 g -> Other filter systems are available on request 111 8959 Sintered filter Spare parts for HygroMate Metal web filter for the HygroMate Metal web filter system : Replacement metal web filter Dimensions : 34 x 12.5 mm A robust metal web filter made of stainless steel. Material : Stainless steel, plastic Prevents particles larger than 100 um from reaching Response time : T50 ca. 10 sec. the sensor system and provides active protection. The Weight : 20 g instrument is delivered with this filter installed. 111 8960 Metal web filter Capacitive measurement cell Capacitive humidity measurement cell: Replacement measurement cell for the Hygro Mate Dimensions : 4 x 15 mm A replacement capacitive humidity measurement cell Weight : 2g only for the HygroMate instrument. It is important that Measurement : capacitive a new 2 point calibration is performed with the SAL-stray field : +/-20% rh !! SC checks 11% and 75% rh when the cell is replaced. A new 2 point calibration must be performed when this cell is Attention: In no circumstances should the cell be touched with the replaced! 111 8961 measurement cell bare hands. The cell should only be Replacement should only be done by a skilled person. replaced by a Novasina agent!! Doc. 004701.00 General catalogue AIR 2014 page 5 / 34 Data logger line - humidity / temperature / pressure HygroGuard 10 or 20 This new data logger series excel with useful functions and high versatility. As stand-alone devices or integrated in PC-networks the HygroGuard 30, ClimaLog 30 and DataLog 30 can be used in various applications for climatic data measurement and recording. The high storage capacity of 3'2 Mio data points and the AA batteries with >1 year of operation life make this data logger system ideal for many applications. The data visualisation and device configuration is done by the Windows software SmartGraph III which is included in the delivery. Novasina data logging product range: HygroGuard 30 with internal sensors for humidity and temperature ClimaLog 30 with internal sensors for humidity, temperature and absolute pressure sensors DataLog 30 with no internal sensors ready for 10 signals for monitoring systems. Data transmission is done via a UMB-Bus interface for the ..Maxx series or 2 x 4..20 mA. (e.g. 4 x StatMaxx + 2 PascalMaxx) Features: • High data storage capacity • Large format and flexible display • USB & Ethernet interface (TCP/IP) • Connectable with external sensors via UMB bus for monitoring networks (only Data Log 30) • Versatile and intuitive software for data analysis Model HygroGuard 30 ClimaLog 30 DataLog 30 Data logger systems: Dimensions : 166x78x32 mm MEASURED PARAMETERS Weight : 250 g Temperature X X external sensors Power supply : 4 x LRG AA Mignon Relative humidity X X external sensors batteries, USB Absolute humidity X (calculated) X (calculated) external sensors - life time > 1 year Dew point temp.. X (calculated) X (calculated) external sensors Housing/protection : plastic ABS / IP40 Barometric air pressure X external sensors Data storage : 16 MB, 3'200'000 Analogue inputs ( voltage / current) 2xAI + 8x Bus measured values FUNCTIONS - DEVICE Interface : USB, LAN (Ethernet) Power supply battery X X X Power supply USB X X X Measured data storage 3'200'000 3'200'000 3'200'000 Measurement rate : 10/30s, 1/10/12/15/30 Typ. battery life > 1 year > 1 year > 1 year min., 1/3/6/12/24h LC-Display X X X Storage rate : 1/10/12/15/30min., 1/3/6/12/24h One button operation X X X 1-point calibration by operator X X X °C/°F switchable X X X Humidity measurement: Optical/acoustical alarm X X X Capacitive measurement principle Date / time X X X Measuring range : 10...95% RH Records MIN/MAX/AVG X X X not condensing SmartGraph 3 evaluation software X X X Accuracy : +/- 2.0%rh Resolution : 0.5%rh UMB bus for external sensors X (8x signal) FUNCTIONS - SmartGraph III Graphical representation X X X Temperature measurement: Numerical data table X X X NTC measurement principle Print function X X X Measuring range : -20....50°C Export function (Excel etc.) X X X Accuracy : +/- 0.3°C (0...40°C) Printouts of all measurement sites X X X otherwise +/- 0.5°C User administration X X X Resolution : 0.1°C Administration of up to 255 a loggers X X X Windows API interface X X X Air pressure measurement: Measuring range : 300…1300hPa abs. Applications: Accuracy : +/- 0.5hPa • HVAC installations, clean rooms, calibration and QA laboratories (700…1100hPa) • Museums, archives, libraries, storage rooms Resolution : 0.1hPa • Building Management Systems and monitoring systems • Pharmaceutical- chemical-, biotechnology, food-industry Doc . 004701.00 General catalogue AIR 2014 page 6 / 34 Data logger line - instruments / accessories HygroGuard 30 / CimaLog 30 / DataLog 30 HygroGuard 30 Data logger system Dimensions: 166x78x32 mm Weight: 250 g Battery powered data logger for recording of humidity, temperature/dew point with 16 MB data storage Power supply: 4 x LRG AA Mignon (3'200'000 values) with visualisation and configuration batteries (life time > 1 year) software and big LC-Display 90 x 64 mm. Housing/protection: plastic ABS / IP40 Delivery includes: Storage: 3'200'000 measured val. 260 0867 HygroGuard 30 - HygroGuard 30 device incl. 4 batteries - 2m USB data transfer cable Interface: USB, LAN (Ethernet) - SmartGraph III software (on included CD) Meas. rate: 10/30s,1/10/12/15/ - Operation manual (on the CD) 30min., 1/3/6/12/24h - Novasina factory calibration certificate Storage rate: 1/10/12/15/30min., 1/3/6/12/24h ClimaLog 30 Data logger system Dimensions: 166x78x32 mm Weight: 250 g Battery powered data logger for recording of humidity, temperature/dew point and absolute pressure with Power supply: 4 x LRG AA Mignon 16 MB data storage (3'200'000 values) with visualisation batteries (life time > 1 year) and configuration software and big LC-Display 90 x 64 Housing/protection: plastic ABS / mm. IP40 Delivery includes: Storage: 3'200'000 measured val. 260 0866 ClimaLog 30 - ClimaLog 30 device incl. 4 batteries - 2m USB data transfer cable Interface: USB, LAN (Ethernet) - SmartGraph III software (on included CD) Meas. rate: 10/30s,1/10/12/15/ - Operation manual (on the CD) 30min., 1/3/6/12/24h - Novasina factory calibration certificate Storage rate: 1/10/12/15/30min., 1/3/6/12/24h DataLog 30 Data logger system Dimensions: 166x78x32 mm Weight: 250 g Battery powered data logger for recording max. 10 channels (UMB interface and 2 analogue input U/I). With Power supply: 4 x LRG AA Mignon 16 MB data storage (3'200'000 values) with visualisation batteries (life time > 1 year) and configuration software and big LC-Display 90 x 64 Housing/protection: plastic ABS / mm. IP40 Storage: 3'200'000 measured val. 260 0868 DataLog 30 Recommended external RH/T sensors from Novasina are the Stat Maxx “UMB” or HygroMaxx / TempMaxx / Interface: USB, LAN (Ethernet) PascalMaxx models (see accessories below) and UMB (universal measurement bus) Total : max. 10 channels Delivery includes: 8 channels via UMB - DataLog 30 device incl. 4 batteries 2 channels - 2m USB data transfer cable 0…10V/4…20mA - SmartGraph III software (on included CD) Meas. rate: 10/30s,1/10/12/15/ - Operation manual (on the CD) 30min., 1/3/6/12/24h - Novasina factory calibration certificate Storage rate: 1/10/12/15/30min., 1/3/6/12/24h Accessories for Hygro Guard 30 / Clima Log 30 HygroGuard 30 DKD calibration certificate DKD calibration including official Calibration certificate according to the official DKD certificate accredited procedure. Rel.humidity : 20%, 50%, 80%rh at 20°C Calibration at 3 RH points and 1 temperature point. Temperature : 20°C 260 0871 HygroGuard 30 DKD certificate Doc. 004701.00 General catalogue AIR 2014 page 7 / 34 Data logger line - accessories / options ClimaLog 30 DKD calibration certificate DKD calibration including official Calibration certificate according to the official DKD certificate accredited procedure. Calibration points: Rel.humidity : 20%, 50%, 80%rh Calibration at 3 RH points, 1 temperature point and 5 at 20°C absolute pressure points. Temperature : 20°C 260 0870 Abs. pressure : 5 points ClimaLog30 DKD certificate in range 750 …1100 mbar USB power supply Dimensions: 55x25x80 mm Weight: 50 g Power supply with USB socket to power H ygro Guard 30 Clima Log 30 or Data Log 30 with an external power Input power : 100…260V AC supply. In such cases the internal AA batteries are only 50/60 Hz Output power : +5V DC USB for backup and in case of a power failure. 260 0872 1200mA / 6W USB power supply 2m USB cable already included in data logger package! Housing/protection: plastic ABS / IP40 Options for Data Log 30 monitoring systems StatMaxx S Dimensions: 110 x 118 x 50mm The StatMaxx S is a universal measurement instrument Probe: diameter 13 x 58 mm for air humidity and temperature measurement in rooms. Weight: 220 g The instrument has an UMB interface (4 units up to Power supply: 24 VDC ± 20% 150m total bus cable length) and the possibility of a 2 point control/alarming with an internal relay (isolated 30V Outputs: UMB interface for 4 switch for LOG-PU power supply) StatMaxx and DataLog 30 1 ON/Off switch Delivery includes: 30V / 2 A for alarm Mounting accessories and operating manual control with set point 260 0840 StatMaxx S Optional: factory calibration RH/T 33, 75 % RH / 25°C StatMaxx R Dimensions: 110 x 118 x 50mm The StatMaxx R is a universal measurement instrument Probe: diameter 13 x 250 mm for air humidity and temperature measurement in ducts. Weight: 240 g The instrument has an UMB interface (4 units up to Power supply: 24 VDC ± 20% 150m total bus cable length) and the possibility of a 2 point control/alarming with an internal relay (isolated 30V Outputs: UMB interface for 4 switch for LOG-PU power supply) StatMaxx and DataLog 30 1 ON/Off switch 260 0839 StatMaxx R Delivery includes: 30V / 2 A for alarm Mounting accessories and operating manual control with set point Remark: Optional: factory calibration RH/T Duct mounting kit is not included and must be ordered 33, 75 % RH / 25°C separately, see below. StatMaxx M Dimensions: 110 x 118 x 50mm The StatMaxx M is a universal measurement instrument Probe: diameter 13 x 250 mm with for air humidity and temperature with remote sensor with 3 m cable 3m cable. The instrument has an UMB interface (4 units Weight: 240 g up to 150m total bus cable length) and the possibility of a Power supply: 24 VDC ± 20% 2 point control/alarming with an internal relay (isolated 30V switch for LOG-PU power supply) Outputs: UMB interface for 4 StatMaxx and DataLog 30 Delivery includes: Mounting accessories and operating manual 1 ON/Off switch 260 0841 StatMaxx M 30V / 2 A for alarm Remark: control with set point Duct mounting kit not included (see accessories) Optional: factory calibration RH/T 33, 75 % RH / 25°C Doc. 004701.00 General catalogue AIR 2014 page 8 / 34 Data logger line - options / installation example Duct mounting kit Duct mounting kit StatMaxx R : Duct mounting flange for StatMaxx R. For easy and Dimensions : 60 x 20 mm tight mounting to ducts or through walls/ceilings incl. sealing O-ring.Installation with 3 screws.The 13mm tight Weight : 30 g 111 5343 flange hole resists an overpressure of 3 bars. Sensor Installation range: diam. 9…14mm Duct mounting kit can be removed at any time for adjustment. -> Diameter fixation range: diam. 10 ...14 mm LOG-PU Dimensions: 215x110x90 mm power unit and wiring Weight: 800 g Power supply unit for monitoring system for 1 Data Log 30 and up to 4 external sensors Stat Maxx, HygroMaxx, Input power : 115…230V AC TempMaxx and PascalMaxx. 50/60 Hz Output power : 24V DC / 15W 0.63 A Building up a simple network node with up to 10 Ready for UMB bus cable (2x2 wire measurment values requires a 115…230 VAC power 260 0869 for power and signal) up to 4 LOG-PU supply and Ethernet TCP/IP connection (RJ 45). …Maxx instruments. UMB-bus connector Dimensions: 20 x 60 mm Connector for UMB-bus cable connection between a Weight: 30 g Data Log 30 unit and UMB sensors (e.g. Stat Maxx). Connection: 5 pol with screw for UMB bus and Note: Power of the StatMaxx The Data Log 30 device has also an additional analogue 260 0873 UMB connector Ready for UMB bus cable (2x2 wire input that can be used parallel to the UMB connection. for the DataLog 30 for power and signal) UMB-bus length max. 150 m Installation example Doc. 004701.00 General catalogue AIR 2014 page 9 / 34 HVAC line - relative humidity/temperature transmitters HygroMaxx High performance measuring instrument with large LCDisplay for air relative humidity and temperature. For installations in rooms or ducts. The digital capacitive humidity measurement cell in conjunction with a newly developed sensor technology, enable this device to be used in various applications for measuring climatic parameters. Operation is effected via 3 keys and an intuitive menu. The HygroMaxx transmits 2 analogue outputs for relative humidity and temperature. These can be scaled as required. Optimal integration into a control system can therefore be achieved. The HygroMaxx is available in different versions for room and duct measurement. Technical specifications at a glance: Working range RH : 0....100% RH Working range T : -20...80°C (sensor) 0...50°C (transmitter) Meas. accuracy : RH: +/- 3.0% RH at 5...95% RH and 0...50°C +/- 1.5% RH at 10...90% RH and 15...30°C (with 3 point calibration with SAL-SC hum.standards) T: +/- 0.5°K at 0....50°C / +/- 0.8°K at -20...80°C Signal output : 2 analogue outputs U/I (switch able) U :0....10V : 2...10V / I : 0...20mA : 4...20mA freely scalable output-characteristic curve operated by integrated configuration menu Display : 2 line display RH and Temp. Contemporaneously, error/menu control display, Dimensions 60x30 mm Functions : units °C / °F, adjustment at 3 humidity points and 1 temperature point, scalable analogue outputs, moving average display ¼, 1, 3 hours, key lock by password Adjustment : checkable and adjustable at any time at 3 RH points using the proven Novasina humidity standards SAL-SC Measurement principle : RH: digital capacitive CMOS-Sens® technology Temp.: digital PN barrier layer HygroMaxx Measurement instrument HygroMaxx: For monitoring and controlling Dimension : 110 x 118 x 50mm Humidity/temperature transmitter for HVAC and process controls with local Power supply : 24 V DC ± 20% LCDisplay. Probe length S-type : diam.13 x 58 mm Probe length R-type: diam.13 x 250 mm The HygroMaxx product series have been developed following the newest technology in monitoring and controlling in the HVAC sector. These products Humidity measurement: ® represent an ideal combination of performance and price. The new sensor CMOS-Sens technology, digital capacitive technology, the configuration possibilities and the robust design set a new Measurement range : 0...100 % RH standard in the HVAC field. Reproducibility : ± 1.0 % RH Max.accuracy (standard) : ± 3.0 % RH Thanks to the new design conception, these instruments are easy for Max.accuracy (calibrated) : ± 1.5 % RH installation and maintenance. Integrated menu functions facilitate the start-Temperature measurement: up, service resp. the RH adjustment with the Novasina SAL-SC humidity digital PN barrier silicon layer standards. Furthermore this product can be easily customised and adapted Measurement range : -20....80°C to specific needs (OEM versions). Reproducibility : +/- 0.1°K Accuracy : +/- 0.5°K (0...50°C) Accuracy : +/- 0.8°K (-20...80°C) Applications: Sensor Checks SAL-SC: • HVAC process-control and -monitoring Humidity standards based on saturated salt • solutions in plastic cylindrical containers. For Paper and textile manufacturing and handling multiple use, with „Cellgard“ humidity • Controls and monitoring systems in labs and metrology rooms permeable membrane. • Monitoring of industrial combustion processes • Storage and archive monitoring in museums and libraries For values: 11%, 33%, 53%, 75%, 90% RH • Storage systems, cooling rooms in the food & pharma industry Doc. 004701.00 General catalogue AIR 2014 page 10 / 34 HygroMaxx instrument types HVAC and industry transmitter system HygroMaxx S / R / M HygroMaxx S Transmitter HygroMaxx S : Humidity/Temperature measurement instruments for rooms Dimension: 110 x 118 x 50mm Probe: diameter 13 x 58 mm HVAC transmitter with stylish designed, robust, two- Weight: 220 g part plastic housing. Ideal for room measurements, Power supply: 24 VDC ± 20% monitoring and controlling of climatic parameters. 24 Outputs: 2 x analogue U/I VDC power supply (no galvanic separation), 2 analogue 0...10V / 2...10V outputs (U or I) for temperature and relative air 0...20mA / 4..20mA humidity. The cable entry easily made via the Meas.range: 0...100% /-20...+80°C housing’s underside. The device is fixed with 4 (only sensor) screws to the wall. The big LCDisplay allows a good Units: RH / °C or °F readability, even from the distance. Various menu Including mounting accessories and operating manual functions and adjustment of RH and T as well as the Optional: factory calibration RH/T 252 3054 Hy groMaxx S analogue outputs and a password protection complete this versatile instrument. HygroMaxx R Transmitter HygroMaxx R : Humidity/Temperature measurement instruments for ducts Dimension: 110 x 118 x 50mm Probe: diameter 13 x 250 mm HVAC transmitter with aesthetic design, robust, two-Weight: 280 g part plastic housing. Ideal for duct measurements, Power supply: 24 VDC ± 20% monitoring and controlling of climatic parameters. 24 Outputs: 2 x analogue U/I VDC power supply (no galvanic separation), 2 analogue 0...10V / 2...10V outputs (U or I) for temperature and relative air 0...20mA / 4..20mA humidity. The cable entry is easily made via the Meas.range: 0...100% /-20...+80°C housing’s underside. The device is fixed directly or (only sensor) Units: RH / °C or °F with a mounting flange to the air duct. The big LCDisplay allows a good readability, even from the Including mounting accessories and operating manual distance. Various menu functions as adjustment of Optional: factory calibration RH/T RH and T as well as the analogue outputs and a Accessories: duct mounting flange password protection complete this versatile 252 3129 Hy groMaxx R (not included in scope of delivery) instrument. HygroMaxx M Transmitter HygroMaxx M : Humidity/Temp.measurement instrument for remote probe Dimension: 110 x 118 x 50mm Probe: diameter 13 x 250 mm HVAC transmitter with aesthetic design, robust, two-Weight: 200 g part plastic housing. The included remote sensor Power supply: 24 VDC ± 20% probe SensMaxx 13 with 3m cable makes this Outputs: 2 x analogue U/I instrument ideal for monitoring and controlling of 0...10V / 2...10V processes, where a high flexibility is required. 24 0...20mA / 4..20mA VDC power supply (no galvanic separation), 2 analogue Meas.range: 0…100% /-20…+80°C 252 3130 (only sensor) Hy groMaxx M outputs (U or I) for temperature and relative air Units: RH / °C or °F humidity. The cable entry is easily made via the Including mounting accessories and Including SensMaxx 13 remote housing’s underside. The device is fixed with 4 operating manual sensor screws to the wall. The big LCDisplay allows a good Optional: factory calibration RH/T readability, even from the distance. Various menu Accessories: duct & wall mounting functions as adjustment of RH and T as well as the flange analogue outputs and a password protection (not included in scope of delivery) complete this versatile instrument. Doc. 004701.00 General catalogue AIR 2014 page 11 / 34 HVAC line - relative humidity/temperature hygrostats StatMaxx The Novasina Stat Maxx is a state-of-the-art hygro/thermostat for effective control applications for relative air humidity and air temperature. The configuration is made by 3 front buttons and an intuitive menu structure directly on the device. The alarm and control function drive an integrated relay switch for turn on/off an heater or humidifier. If you need data monitoring, there is an integrated bus interface (UMB - Universal Measurement Bus) implemented. This characteristics make the StatMaxx very versatile for climatic controls, monitoring and/or management of humidifiers and temperature controllers. This transmitter series offer 2 different models for wall (S type) or duct (R type) mounting. Technical specifications at a glance: Working range RH : 0....100% RH Working range T : -20...80°C (sensor) 0...50°C (transmitter) Meas. accuracy : RH: +/- 3.0% RH at 5...95% RH and 0...50°C +/- 1.5% RH at 10...90% RH and 15...30°C (with 3 point calibration with SAL-SC hum.standards) T: +/- 0.5°K at 0....50°C / +/- 0.8°K at -20...80°C Signal output : - 1 digital output by relay NO/NC max. 260VAC/2A - UMB-bus interface ( - 1 UMB Bus interface (Universal Measurement Bus) Display : 2 line display RH and T,menu display, error messages. Dimensions 60x30 mm Functions : units °C / °F, adjustment at 3 humidity points and 1 temperature point, alarm level setting incl. delay and hysteresis, UMB-bus configuration, moving average display ¼, 1, 3 hours, key lock by password Adjustment : with Novasina SAL-SC standards at 3 RH points with referential instrument at 1 Temp. point Measurement principle : RH: digital capacitive CMOS-Sens® technology Temp.: digital PN barrier layer StatMaxx Measurement instrument StatMaxx: Humidity/temperature hygrostat with LC-Display for HVAC and simple Dimension : 110 x 118 x 50mm process controls. Power supply : 24 V DC ± 20% The StatMaxx hygrostats have the latest state-of-the-art technology on board Probe length S-type : diam.13 x 58 mm and can be used for 2-point controlling systems for humidity and temperature Probe length R-type: diam.13 x 250 mm regulation. The used sensor technologies, the easy configuration possibilities and the robust design make this device ideal for applications in HVAC Humidity measurement: ® processes. CMOS-Sens technology, digital capacitive Measurement range : 0...100 % RH Thanks to its design the Stat Maxx can be easily mounted and put into Reproducibility : ± 1.0 % RH operation. Another plus is the maintenance and calibration that can be Max.accuracy (standard) : ± 3.0 % RH performed on site with the Novasina multiple use SAL-SC humidity Max.accuracy (calibrated) : ± 1.5 % RH standards. Last but not least the small dimensions and the big display assure an ideal positioning and a good readability of the actual values and Temperature measurement: messages displayed on the LCD. Of course and as habitually this instrument digital PN barrier silicon layer can be also customised and adapted to specific customer needs (OEM Measurement range : -20....80°C Reproducibility : +/- 0.1°K versions). Accuracy : +/- 0.5°K (0...50°C) Accuracy : +/- 0.8°K (-20...80°C) Sensor Checks SAL-SC: Applications: Humidity standards based on saturated salt • HVAC process-control and -monitoring (2-point controls) solutions in plastic cylindrical containers. For multiple use, with „Cellgard“ humidity • Paper and textile manufacturing and handling permeable membrane. • Control of humidifiers and heating coils • Storages in various industries such as food & pharmaceutical For values: 11%, 33%, 53%, 75%, 90% RH • Storages, archives in museums, libraries • OEM solutions in combination with humidifiers/dehumidifiers Doc. 004701.00 General catalogue AIR 2014 page 12 / 34 StatMaxx hygrostats / accessories HVAC and industry transmitter system StatMaxx S / R / M StatMaxx S Dimension: 110 x 118 x 50mm Probe: diameter 13 x 58 mm Hygrostat with robust, two-part plastic housing and Weight: 220 g robust design for wall mounting with integrated sensor shaft. Ideal for use in rooms. Power supply: 24 VDC ± 20% Power cable can be easily inserted via the housing Outputs: underside. The device is fixed with 4 screws. - 1 digital output by relay NO/NC max. 30VACDC/2A UMB bus tot. length: max. 150m (4 units +Datalog) - UMB-bus interface (Universal Measurement Bus) Main menu functions are: calibration; alarm, delay Meas.range: 0...100% /-20...+80°C 260 0840 and hysteresis settings; configuration of the UMB S tatMaxx S (only sensor) (Universal Measurement Bus). Units: RH / °C or °F Delivery includes: Mounting accessories and operating manual Optional: factory calibration RH/T 33, 75 % RH / 25°C StatMaxx R Dimension: 110 x 118 x 50mm Probe: diameter 13 x 250 mm Hygrostat with robust, two-part plastic housing and Weight: 220 g robust design for wall mounting with integrated sensor shaft. Ideal for use in air ducts (back side). Power supply: 24 VDC ± 20% Power cable can be easily inserted via the housing Outputs: underside. The device is fixed with 4 screws. - 1 digital output by relay NO/NC max. 30VACDC/2A UMB bus tot. length: max. 150m (4 units + Datalog) - UMB-bus interface 260 0839 S tatMaxx R Main menu functions are: calibration; alarm, delay (Universal Measurement Bus) and hysteresis settings; configuration of the UMB Meas.range: 0...100% /-20...+80°C (Universal Measurement Bus). (only sensor) Delivery includes: Units: RH / °C or °F Mounting accessories and operating manual Remark: Optional: factory calibration RH/T Duct mounting kit not included (see accessories) 33, 75 % RH / 25°C StatMaxx M Dimensions: 110 x 118 x 50mm Probe: diameter 13 x 250 mm with Hygrostat with robust, two-part plastic housing and 3 m cable robust design for wall mounting with integrated Weight: 240 g sensor shaft. Ideal for use in air ducts or rooms Power cable can be easily inserted via the housing Power supply: 24 VDC ± 20% underside. The device is fixed with 4 screws. Outputs: UMB bus tot. length: max. 150m (4 units + Datalog) - 1 digital output by relay NO/NC max. 30VACDC/2A 260 0841 Main menu functions are: calibration; alarm, delay - UMB-bus interface StatMaxx M and hysteresis settings; configuration of the UMB (Universal Measurement Bus) (Universal Measurement Bus). Meas.range: 0...100% /-20...+80°C Delivery includes: (only sensor) Mounting accessories and operating manual Units: RH / °C or °F Remark: Duct mounting kit not included (see accessories) Optional: factory calibration RH/T 33, 75 % RH / 25°C STAT-PU power unit Dimensions: 225x110x90 mm Power supply unit and switch for 2 point control in Weight: 700 g combination with 1 unit StatMaxx for switching ON / Input power : 110…250V AC /15W OFF high power devices (up to 11 kW) like heaters, 50/60 Hz coolers, humidifiers, dehumidifiers. Output power : 24V DC / 15W With integrated 3-phase relay for 115…600V, 500 mA / 15W 11kW, galvanic isolated. Also integrated is a 24V 3 phase galv.isolated switch NO 260 0877 power supply for the StatMaxx and a power switch. STAT-PU max. 11 kW. 1 auxilary contact isolated NO <= 17VDC/5mA 115…600V / 16A Doc. 004701.00 General catalogue AIR 2014 page 13 / 34 HygroMaxx / StatMaxx - accessories Accessories for HygroMaxx & StatMaxx Duct mounting kit Duct mounting kit StatMaxx : Duct mounting flange for easy and tight mounting to ducts or through walls/ceilings incl. sealing O-Dimension : 60 x 20 mm ring.Installation with 3 screws.The 13mm tight flange Weight : 30 g hole resists an overpressure of 3 bars. Sensor can be removed at any time for adjustment. Installation range : diam. 9…14 111 5343 Duct mounting kit -> Diameter fixation range: diam. 10 ...14 mm mm Wall mounting kit 13 mm Wall mounting clip SensMaxx : (for HygroMaxx M type external sensor) Material : polycarbonate Quantity : 2 pcs Wall mounting clips (2 pcs) for the fixation of the SensMaxx 13 probes to walls with M4 wood, plastic Weight : 15 g 252 4468 or metal screws. Clips can be used several times. Wall mounting Clip Sensor-Checks SAL-SC (rh standards) Humidity values in the temperature range 15° .... 30°C: Humidity standards based on saturated salt solutions 11.3 ..... 11.3% rF / 15....30°C in plastic cylinders with moisture permeable 33.3 ..... 32.4% rF / 15....30°C membranes. Each salt is delivered in a well-sealed 55.9 ..... 51.4% rF / 15....30°C box. Sensor Checks SC are obtainable for the 60.7 ..... 56.0% rF / 15....30°C following values (at 25°C) : 75.6 ..... 75.1% rF / 15....30°C 111 0885 -> SAL-SC 11 85.9 ..... 83.6% rF / 15....30°C 111 0855 90.9 ..... 89.9% rF / 15....30°C -> SAL-SC 33 11.3 % rh colour white 75.3 % rh colour purple 97.9 ..... 97.0% rF / 15....30°C 111 0857 -> SAL-SC 53 32.8 % rh colour blue 84.3 % rh colour white 260 0219 -> SAL-SC 58 52.9 % rh colour green 90.1 % rh colour white 111 0859 57.6 % rh colour white 97.3 % rh colour yellow -> SAL-SC 75 The precision corresponds to the 251 8965 Greenspan Report 1977 -> SAL-SC 84 typically +/- 0.3 % rh 111 0896 -> SAL-SC 90 Important: please consult the operation manual of 251 8966 your instrument to see which points can be Weight : 90 g -> SAL-SC 97 calibrated. Other SAL-SC can be used for verification. Sensor-Checks SAL-SC Internationally accredited laboratory with European certificate Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SAL-SC are obtainable for the 111 1044 -> SAL-SC 11 C following values (at 25°C) : All Novasina humidity standards 111 1037 -> SAL-SC 33 C 11.3 % rh colour white can also be supplied with an 111 1040 -> SAL-SC 53 C 32.8 % rh colour blue internationally recognised certificate 111 1035 from an accredited European -> SAL-SC 75 C 52.9 % rh colour green laboratory (UKAS England). 111 1032 75.3 % rh colour purple -> SAL-SC 90 C 84.3 % rh colour white Weight : 90 g 90.1 % rh colour white Set with 5 Sensor-Checks SAL-SC Case with all 5 Sensor Checks from 11 to 90%rh: Humidity standards based on saturated salt solutions Humidity values in the temperature in plastic cylinders with moisture permeable range 15°... 30°C : membranes. Each salt is delivered in a well-sealed 11.3 ..... 11.3% rF / 15....30°C box. Sensor Checks SAL-SC are obtainable for the 33.3 ..... 32.4% rF / 15....30°C following values (at 25°C) : 55.9 ..... 51.4% rF / 15....30°C 11.3 % rh colour white 75.6 ..... 75.1% rF / 15....30°C 32.8 % rh colour blue 90.9 ..... 89.9% rF / 15....30°C 52.9 % rh colour green The precision corresponds to the 75.3 % rh colour purple Greenspan Report 1977 111 7847 Check set (standard) 90.1 % rh colour white typically +/- 0.3 % rh 111 7841 Empty case for set Weight : 900 g Doc. 004701.00 General catalogue AIR 2014 page 14 / 34 HygroMaxx / StatMaxx - accessories / spare partss SAL-SC Sensor check adapter CH CH adapter to SAL-SC salts for sensors with diameter 13 mm: for sensors with diameter 13 mm This adapter is needed for calibration of a system Dimensions : 30 x 13 mm with sensor diameter 13 mm. It ensures an airtight Material : Polycarbonate, fixation of a SAL-SC check to the sensor top rubber 110 7345 Adapter CH (measurement cell area). It reduces the diameter of Weight : 5 g 20 mm to 13 mm and ensures an airtight seal. -> The adapter should be first mounted on the sensor top and then putted the SAL-SC check on it. Both seals should be carefully checked, leaks will bias the calibration. Thermal insulation styrofoam box Styrofoam box for the SC check: For the SAL-SC sensor checks Dimensions : 100 x 65 x 50 mm A styrofoam box providing optimal insulation and Weight : 10 g temperature stabilisation of a SAL-SC check during Material : thermal insulating the calibration procedure. Consisting of two half- styrofoam PPE covers for simple temporary mounting. -> Can be used together with the SAL-SC calibration kit 111 1302 Styrofoam box Spare parts for Hygro Maxx & Stat Maxx Spare plug set - HygroMaxx Spare plug set for HygroMaxx: Plug : 2 pole 3.84 mm Spare plug set for main board, for power supply and for power supply analogue outputs. 3 pole 3.84 mm for analogue outputs Attention: use only 24 VDC +/- 10% power supply ! Weight : total 20 g 252 3134 Spare part plug set Spare plug set - StatMaxx Spare plug set for StatMaxx: Plug : - 3 pole 3.84 mm Spare plug set for main board, for power, UMB and for power supply & Relay output digital output - 6 pole 3.84 mm for UMB bus 260 0884 Spare part plug set - 4pole for switch 230V Weight : total 15 g Spare room sensor Spare sensor : Dimension : Ø 13 x 75 mm Spare sensor for S-type transmitters. The sensor (length 75 mm) can be replaced by un-tighten the 2 Cable : 150mm with RJ 11 screws in the cover and unplugging the RJ 11 Weight : 15 g 252 3131 connector. room sensor for S- Housing : plastic armature type transmitters Recommendation: switch off the power supply before you replace without filter the sensor Spare duct sensor Spare sensor : Dimension : Ø 12,7 x L 250 mm Spare sensor (length 250mm) for R-type transmitters. Duct mounting flange not included. Cable : 150mm with RJ 11 Weight : 80 g Recommendation: switch off the power supply before you replace Housing : stainless steel with 252 3132 the sensor duct sensor protection filter Remote sensor for HygroMaxx M Spare sensor : Dimension : Ø 12,7 x L 250 mm Spare remote sensor with 3m cable. Duct mounting flange not included. Cable : 3m with free wire endings ! 252 3133 remote sensor Recommendation: switch off the power supply before you replace Weight : 150 g the sensor Housing : stainless steel with protection filter Doc. 004701.00 General catalogue AIR 2014 page 15 / 34 HygroMaxx / StatMaxx - spart parts /options Remote sensor for StatMaxx M Spare sensor : Dimension : Ø 12,7 x L 250 mm Spare remote sensor with 3m cable. Duct mounting flange not included. Cable : 3m with free wire endings ! Recommendation: switch off the power supply before you replace Weight : 150 g the sensor Housing : stainless steel with protection filter 260 0940 remote sensor Housing bottom Spare housing bottom: Dimension : 110 x118 x 35 mm As spare part for damaged housings. Weight : 80 g Material : PVC 252 3135 housing bottom Options Hygro Maxx & Stat Maxx External power supply 90...264VAC/EUR Technical data: Primary side : External primary power supply, for voltage range 90 Voltage range: 90 ... 264VAC to 264 VAC with Euro plug system. Euro plug Secondary side : Voltage: 24V DC +/- 5% From the secondary side this power supply can be connected directly to the transmitter. Cable ends unshielded and ready for connection. 252 4210 power supply Weight: 90 gr Ext. power supply 90...264VAC / US/JP Technical data: Primary side : External primary power supply, for voltage range 90 Voltage range: 90 ... 264VAC to 264 VAC with US/Japan plug system. US/JP plug Secondary side : Voltage: 24V DC +/- 5% From the secondary side this power supply can be connected directly to the transmitter. Cable ends unshielded and ready 252 4211 power supply for connection. Weight: 90 gr Factory calibration Factory calibration certificate : Including Novasina factory calibration certificate The shipping of new instruments is Factory calibration and certificate for 3 humidity always including factory calibration points (11%, 53%, 75% RH) & 1 temperature point certificate, provided that the (+25°C). calibration has been ordered with -> Enables a higher measurement accuracy PN 2524212. 252 4212 UKAS certification International certified laboratory in an accredited European laboratory UKAS certification at min. two humidity points and if required at one or more temperature points. For M versions, the remote sensor has to be sent Novasina offers the possibility to together with the corresponding transmitter. See price list calibration buy UKAS certified measuring instruments. Doc. 004701.00 General catalogue AIR 2014 page 16 / 34 HVAC line - temperature transmitters & thermostats TempMaxx The TempMaxx is a precision measurement instrument with integrated control functions for the detection of temperature with external resistor sensors. The large displays, intuitive menu structure as well as the possibility to connect various sensors make this device extremely versatile for almost all industrial applications. The external sensors can not only detect very accurately the temperature in air, but also in liquids, solid objects and surfaces. A digital electronics design allows using the TempMaxx transducer in manifold applications such as monitoring, control and alarming. This new instrument provides a scalable analogue output (U & I) as well as a relay switch output for 2 point control functions. The large LCDisplay indicates temperatures up to +400°C and °F. All versions of PT 100 / 1'000, Ni 1'000 or NTC elements can be wired in 2-, 3- or 4-wire technology. Using the integrated adjustment function, the TempMaxx transducer can be adapted ideally to each external sensor. Temperature : 0...50°C (operational temperature transducer) -50...400°C (meas. range PT 100/1'000 sensor) -50...200°C (meas. range Ni 1'000 sensor) -20...80°C (meas. range NTC Beta Therm sensor) Accuracy : +/- 0.15% Full scale (transducer accuracy) depending on resistor element (see PT DIN classifications) Signal output : 1 analogue output U & I (usable in parallel) U: 0....10V ; 2...10V / I: 0...20mA ; 4...20mA free scalable output curve by configuration menu 1 digital output by relay NO/NC max. 260VAC/2A Display : 2-line display for temperature °C or °F and Status/Error/Menu display, dimensions 60x30 mm Functions : Selectable units: °C / °F, Scalable analogue outputs Setting of hysteresis and delay for alarm- or 2-point control purposes Password protection system Adjustment : 2-point temperature adjustment for each sensor type Measurement principle : Platinum-, Nickel-resistor elements, NTC thermistors TempMaxx for HVAC applications Transducer TempMaxx: For monitoring and process control Dimension : 110 x 118 x 50mm Temperature transducer for HVAC and process controls with LCDiplay. Power supply : 24 V DC ± 20% The TempMaxx product line has been developed following the most recent Outputs: know-how in the HVAC control field. This line brings an ideal symbiosis of Analogue OUT : 1 x U and I performance and price. The robust and ergonomic design of the whole 0 or 2...10V DC ...Maxx product line has been developed especially for industrial applications. 0 or 4...20 mA DC Thanks to its clever design the instrument can be installed very easily and Digital OUT : 1 relay switch also the maintenance can be done efficiently. The integrated menu functions NO, NC ease the start-up and the calibration procedure. The complete product line max. 260 VAC / 2A can also be customised if required. (ohmic load) Temperature measurement: Applications: Sensor connection : 2-, 3- or 4-wire • HVAC process-control and -monitoring • Paper and textile manufacturing and handling Sensor types : PT 100 DIN 60751 • Controls and monitoring systems in labs and metrology rooms PT 1'000 /Ni 1'000 • Monitoring of industrial combustion processes AA, A, B, 1/3B, C • NTC type Beta Therm Storage and archive monitoring in museums and libraries • Storage systems, cooling rooms etc. in food & pharmaceutical industry Doc. 004701.00 General catalogue AIR 2014 page 17 / 34 TempMaxx - transmitters & thermostats / accessories HVAC and industry transducer system TempMaxx TempMaxx Transducer TempMaxx : Temperature transducer for resistor sensors Dimension : 110 x 118 x 50mm Sensor : 13 x 75 mm Temperature transducer with robust industrial Weight : 220 g design. 2-part plastic housing with catcher (no screws for lid needed). Power : 24 VDC ± 20% The transducer is delivered without resistor sensors, supply which should be procured separately. Suitable for Output : 2 x analogue U/I connection are all PT 100/1'000, Ni 1'000 and NTC 0...10V / 2...10V resistor elements in various designs with 2-, 3- or 4-0...20mA / 4..20mA wire connection. Possible measurement ranges: Optimal for climatic measurements or for monitoring sensors and controls. Power supply 24VDC (no galvanic -50...400°C (PT 100/1'000) isolation), 1 analogue output (U and I in parallel) for 260 0284 TempMaxx - 50...200°C (Ni 1'000) temperature, freely scalable. Furthermore the transducer - 20...80°C (NTC Beta Therm) transducer has 1 relay switch NO or NC with for resistor temperature selectable threshold, hysteresis and delay on board. Transducer operational temp.: measurement sensors The electrical cable insertion comes from the back 0...50°C without sensor side resp. bottom side. The instrument can be Units : °C or °F directly fixed to the wall using 4 screws. The large Optional : factory calibration T LCDisplay allows a reading from a big distances and several other menu functions such as sensor and output range selection, calibration and password protection complete this versatile transducer. Accessories NTC Thermistor NTC Beta Therm sensing -20 ... +80°C : element: Cost efficient, accurate and very small NTC Pearl diameter : 2.4 mm temperature sensor element for a direct 2-wire Length : 40.0 mm connection to the TempMaxx. Material : glass / CU Pearl diameter : 2.4 mm Quantity : 1 pc Material : glass Weight : 4 gr 260 0633 Resistivity at 25°C : 30 k Ohm 30K5A Beta Therm NTC Sensor element singular Connection : AWG 3 isolated PT 100 Cable duct sensor -50...+200°C Duct Sensor PT 100 with cable: Universally applicable air cable duct sensor for Dimension : 6 x 50 mm VA4 Cable length 3m silicone extended temperature range up to +200°C. double isolated Sensor PT 100 1/3 DIN Sensing element : PT 100 1/3 DIN 260 0634 Weight : 140 gr PT 100 Duct sensor Casing : Immersion sleeve for gases & 1/3 DIN with 3m silicone cable liquids, 6mm x 50mm sensor IP65 Connection : 2-wire Connection : 2-wire technology, bared ending PT 100 Air-cable sensor -35...+105°C Air sensor PT 100 with cable: Fast responding air cable sensor for measurement of Dimension : 6 x 50 mm VA4 Cable length 5m PVC gases up to +105°C. double isolated Sensor PT 100 1/3 DIN Sensing element : PT 100 1/3 DIN Casing : Steel protection sleeve VA4 Weight : 130 gr 260 0635 6mm x 50 mm with holes PT 100 Air sensor Connection : 4-wire 1/3 DIN with 5m cable Connection : 4-wire technology, bared ending Doc. 004701.00 General catalogue AIR 2014 page 18 / 34 TempMaxx - accessories PT 100 Air-duct sensor -30...+180°C Air-duct sensor PT 100: Universally applicable gas duct sensor with duct Dimension : 6 x 150 mm VA4 Housing : 60 x 80 x 39 mm probe length 150mm for temperature measurements Material : PVC M16 compres- in gaseous media in air ducts up to +180°C. sion gland Sensing element : PT 100 1/3 DIN Sensor : PT 100 1/3 DIN Casing : Stainless steel probe VA4 Weight : 110 gr 6mm x 150mm, IP 65 protection PVC housing for connection Connection : 4-wire Connection : 4-wire technology with 260 0636 PT100 Air-duct compression gland sensor,1/3 DIN,4-wire PT 1000 Air-room sensor -35...+70°C Air-room sensor PT 1'000 : Shapely air sensor for temperature measurements in Dimension : 87 x 85 x 30 mm Material : ASA with rooms applicable up to +70°C, including white PVC ventilation slots housing. Sensor : PT 1'000 Sensing element : PT 1'000 2-wire, 1.5 mm2 Housing : PVC colour white, IP 20 Weight : 80 gr only for applications in non 260 0637 PT 1'000 Air-room aggressive gases Connection : 2-wire sensor, 2-wire Connection : 2-wire technology, screwable ...Temperature sensors Other temperature sensors on request for TempMaxx Doc. 004701.00 General catalogue AIR 2014 page 19 / 34 TempMaxx - options / spare parts Options External power supply 90...264VAC/EUR Technical data: Primary side : External primary power supply, for voltage range 90 Voltage range: 90 ... 264VAC to 264 VAC with Euro plug system. Euro plug Secondary side : Voltage: 24V DC +/- 5% From the secondary side this power supply can be connected directly to all TempMaxx types. Cable ends unshielded and ready for connection. Weight: 90 gr 252 4210 power supply 24V EUR Ext. power supply 90...264 VAC / US/JP Technical data: Primary side : External primary power supply, for voltage range 90 Voltage range: 90 ... 264VAC US/JP plug to 264 VAC with US/Japan plug system. Secondary side : Voltage: 24V DC +/- 5% From the secondary side this power supply can be connected directly to all TempMaxx types. Cable ends unshielded and ready for connection. Weight: 90 gr 252 4211 power supply 24V US/JP Spare parts Spare connector set to TempMaxx Spare connector set to TempMaxx: Spare connector set for PCB to TempMaxx Connectors:2 pin 3.84 mm Power for power supply, sensor input, analogue output and 4 pin 3.84 mm AOUT alarm (set with 4 pcs). 6 pin 3.84 mm SENS 3 pin 5.08 mm ALA Incl. 2 jumpers for switching from 2-, 3-, or 4-wire technology wiring. Packed inside plastic bag. 260 0303 Spare connector set Temp Maxx Housing lower half for TempMaxx Spare housing bottom for TempMaxx : As spare part for damaged housings. Dimension : 110 x118 x 35 mm Weight : 80 g Material : PVC 252 3135 housing bottom TempMaxx Doc. 004701.00 General catalogue AIR 2014 page 20 / 34 PROCESS line - relative humidity/temperature transmitters HygroDat 100 Precise and robust humidity and temperature measurement instrument for control and regulation of industrial processes, as well as monitoring and data recording. This transmitter system is capable to run two different measuring principles, depending on the application. It is possible to either use the resistive electrolyte or the digital capacitive measuring system. The electrolyte measurement system achieves a higher accuracy and the digital capacitive measurement works in a bigger temperature range. The customer can chose the most suitable sensor type to be connected to the transmitter. With its multiple communication possibilities and the freely configurable analogue outputs, this extremely versatile system can be ideally used for all industrial applications and if required in combination with process control units. Relative humidity : 6....100% rh (electronic saturation protection) Temperature : -20...80°C (E-sensor) (-40…..+120°C C-sensor) Precision : +/- 0.5% rh 11...95% rh at 25°C (E-sensor) +/- 2.0% rh 11...95% rh at 25°C (C-sensor) Basis - 5-point calibration with SAL-SC-Set +/- 0.2°K 0....50°C (32....122°F) Communication : 2 freely scalable analogue outputs U :0....10V : 2...10V / I : 0...20mA : 4...20mA for Temp and RH, Td, enthalpy, water content. CAN digital bus system with the CANopen protocol supporting up to 127 H-100 instruments RS 232 interface for peer to peer communication with NovaLog 32 visualisation software or WinDLL Climate computer : instrument can be switched to all ISO and US units, • Air temperature °C -> °F • Relative humidity % rh • Dew point temperature °C -> °F • Specific enthalpy J/kg -> btu/lb • Mixing ratio g/Kg -> g/lb HygroDat 100 The standard for humidity and temperature Measurement instrument HygroDat 100 measurement in industry with unsurpassed precision Polycarbonate housing: Dimensions : 140 x 180 x 71mm The multi-talented system, combining the latest electronics with highly reliable Power : 24 V AC / DC software architecture. Depending on the application, you decide which 90...230V AC measurement technology you prefer. The unsurpassed resistive electrolytic 50/60Hz humidity measurement cell, or the digital capacitive cell, both running on the same transmitter system. This simplifies considerably the evaluation of the right instrument and simplifies the installation, operation, service and calibration. The appropriate industrial design and the various combinations of transmitters and sensors make it possible to provide the ideal solution for every Humidity measurement: (E-sensor) specific application. The sensor can be installed up to 30m (C-sensor) or 100m Resistive electrolytic measurement cell (E-sensor) from the transmitter unit. There is no inaccuracy due to the cable Measurement range: 6....100 % rh Precision : +/- 0.5 % rh lengths and it can be shortened and extended as required without any lack of Capacitive measurement cell precision. Measurement range: 0....100 % rh A variety of hard- and software functions complete the instrument. These Precision : +/- 2.0 % rh include free scalability of the analogue outputs, easy recalibration using (Based on 5-point calibration with SC at 25°C) Novasina’s humidity standards SAL-SC as well as an integrated climate computer (Hx-diagram), variability of units, calibration alarm and password Temperature measurement: (E-sensor) protection. High precision NTC resistance element Measurement range : -20....80°C Repeatability : +/- 0.1 K Applications: Precision : +/- 0.2 K • Monitoring and control of pharmaceutical production processes (-20°...+80°C) • Paper and textile production and processing • Laboratory test and measurement rooms monitoring Sensor Checks SAL-SC: • Chemical process control and monitoring Humidity standards based on saturated salt • Control of industrial combustion processes (turbine exhausts) solutions in plastic cylinders with a moisture permeable membrane. • Storage and archive monitoring • Nuclear power station air conditioning processes Values: 11%, 33%, 53%, 75%, 90%rh. • Clean rooms in pharmaceutical, semiconductor, biotech production Doc. 004701.00 General catalogue AIR 2014 page 21 / 34 HygroDat 100 EC - transmitters Precision industrial transmitter system HygroDat 100 Thanks to its modularity, the most modern humidity and temperature transmitter system HygroDat 100 can be configured optimally, what helps to find the best solution for almost all specific industrial applications. A real innovation is the fact that you can chose from 5 different sensor-armatures to be connected to the transmitter unit. Furthermore there is the possibility to communicate by a RS-232 interface and run a visualisation and recording software on a PC (peer to peer connection). Polycarbonate HygroDat 100 HygroDat 100 polycarbonate: Dimensions : 130 x180x 66.5mm Industrial transmitter with 24V AC/DC or Weight : 530 g 90…260V AC power supply. Blue/grey plastic Power supplies : 15...40 VDC 16...30 VAC housing with IP65 protection class. 90...260 VAC up to 60 Hz Designed for connecting HIA, HIS, HIC, HICS and Power used : AC max. 3.5 W HICH electronic sensors via a 5 wire cable up to a DC max. 3.0 W length of 30m (C-sensors) or 100m (E-sensors). Outputs : 2 x Analogue U/I 0...10V / 2...10V The transmitter is supplied in a single package with 0...20mA / 4..20mA an electronic sensor. The complete system has been or CAN bus or RS-232 Ranges : 6.....100% 5-point adjusted prior to delivery (factory calibration) Polycarbonate housing -20°…..+80°C 111 6930 Units : ISO / US switchable HygroDat 10024V AC/DC - > The sensor should always be used as a unit with the °C, °F, % rh, KJ/kg 111 6931 HygroDat 10090…230V transmitter. E-sensors : HIA und HIS g/kg, btu/lb C-sensors : HIC, HICS und HICH PC-Software NOVALOG 32 For PC/Laptop and WIN Operating systems to HygroDat 100 RS-232 to HygroDat 100: CD : - NOVALOG 32 software Visualisation software for Windows based PC- - Operating instructions Systems on a CD incl. operating instructions for - DLL driver to HD 100 HygroDat 100-E and -C. With it, long term data PC/Laptop : Windows op. system recordings (logging mode), trend graphs, but also RS-232 : COM 1...12 111 6855 NovaLog 32 climatic parameter calculations can be made. This interface at software requires a Windows 9x/2000/NT/XP PC / Laptop operating system. PC/Laptop converter USB-RS232 USB to RS-232 converter: to PC/Laptop for COM applications Cable length : 100 cm For Laptops without D-Sub RS232 connector. Weight : 50 g For conversion of USB to RS-232 for Windows Connector : D Sub-9 (COM Port) 98/ME/2000/NT/XP MAC OS 8/9 or Linux systems. Socket : USB connector This is needed for connecting the HygroDat 100 with Cable is supplied with driver the „NovaLog 32“ software. software. 111 9415 USB-RS232 Such converters are also available in computer shops. Doc. 004701.00 General catalogue AIR 2014 page 22 / 34 HygroDat 100 EC - remote sensor units E-sensors for HygroDat 100 EC resistive electrolytic measurement system E-sensors are humidity and temperature measuring elements, which include a measuring cell on the basis of a liquid electrolyte, a specific humidity measurement technology developed by Novasina. Advantages: Operation limits: • Highest accuracy of the relative humidity measurement • Measuring range humidity : 6.....100% rh • Very small measuring hysteresis over a large range • Basic accuracy of the CC-1 : +/- 2.0% rh • High reaction speed of the measurement till about 1%rh • Air velocity : 0....15m/sec. from the final value. (depending on protection filter type) • Good chemical stability and mechanical robustness • Temp. oper. range short term : -20....+80°C • Great advantage of stability at relative air humidity values • System accuracy at 25°C : +/- 0.5% rh above 90%rh when fully calibrated with 5 Sensor-Checks SAL-SC • Saturation protection by active cell heating system • Temp. oper. range long term : -20....+70°C Please note that the E-Sensors must be operated within their specified limits. The risk of a defect increases at high humidity levels with simultaneous vibrations or mechanical shocks. In such circumstances the electrolyte fluid becomes very aqueous and parts of it might be separated from the liquid holder due to strong shocks. This may cause wrong humidity values. HIA sensor (electrolytic) HIA electronic sensor armature: Dimensions : 160 x 13 mm A modern, small and light electronic sensor in a Weight : 100…800 g plastic housing in IP65 protection class. Includes Measurement : rh -> resistive integrated ASIC technology for optimal signal temperature -> NTC Connection : 5-wire cable processing (temp. & rh), an exchangeable CC-1 (5x 0.5mm2 LiYY) resistive electrolytic measurement cell, a plastic Power : Special membrane protective cap and a 13mm ASIC interface polycarbonate shaft system that can be extended Outputs : 2 x Analogue (U) Shaft length 100mm during installation if required. Protection : Plastic membrane 111 7245 HIA-11: 1.5m cable Accessories: 1 wall mounting clip & 1 duct mounting filter 111 7247 HIA-12: 10m cable flange, incl. in the scope of delivery. -20°…..+80°C 111 6934 HIA-13: 20m cable Ranges : 6.....100% (Electronic -> Please use Sensor Check Adapter PN 1107345 for the saturation protection) 111 6935 HIA-1x: up to 100m cable SAL-SC calibration kit to ensure correct sealing -20°…..+80°C HIS sensor (electrolytic) HIS electronic sensor armature: Dimensions HIS-11, 12, 13: 160x20 mm A modern, robust electronic sensor in stainless steel Dimensions HIS-23: 310x20 mm Weight : 200….1000 g housing in IP65 protection class. Includes integrated Measurement : rh in %, resistive ASIC technology for optimal signal processing temperature NTC (Temp. & rh), an exchangeable CC-1 resistive Connection : Standard 5-wire electrolytic measurement cell, a stainless steel installation cable protective cap with protective membrane. The (5x 0.5mm2 LiYY) Shaft length 160mm diameter 20mm sensor shaft is available in two Power : Special. 111 7532 HIS-11: 1.5m Cable different lengths. ASIC Interface 111 7533 HIS-12: 10m Cable Outputs : 2 x Analogue (U) 111 7534 HIS-13: 20m Cable Accessories: 2 wall mounting clips, incl. in the scope of ASIC Interface 111 7535 Protection : Plastic membrane HIS-1x : up to 100m delivery. filter Shaft length 310mm -20°…..+80°C 111 7751 HIS-23: 20m Cable Option: duct mounting flange not incl. in the scope of delivery. Ranges : 6.....100% (Electronic 111 7752 HIS-2x: up to 100m Cable saturation protection) -20°…..+80°C Option to E-sensors (already included for C-sensors) Interface C/E Sensor RS-232 RS-232 to HygroDat 100: Optional part to HygroDat 100 Transmitters equipped with E-sensors Dimensions : 70 x 50 x 20mm Optional RS-232 interface for HygroDat 100 Weight : ca. 50 g transmitter with E-sensor (HIA, HIS). This interface Power supply: intern. from cover permits a serial data transfer to DDC, PLC or SPS electronics HD 100 controls etc.. RS-232 : standard level Inputs : 1 x E-Sensor It can be also used for the connection of the (1 x C-Sensor) instrument to a PC running the Novasina NovaLog Max. cable length for serial 32 visualisation software. Interface : 15 m 111 9621 Data protocol : ASCII string RS-232 Note: This component is already built in as a standard in HygroDat for HygroDat100 100 transmitters with C-sensors (HIC, HICS, HICH). Doc. 004701.00 General catalogue AIR 2014 page 23 / 34 HygroDat 100 - remote sensor units C-sensors for HygroDat 100 EC ( digital capacitive measurement system) C-sensors are measuring probes with integrated humidity and temperature measuring cell, based on a digital capacitive measuring technology. The miniaturized polymer sensor as key element is much higher integrated than other available capacitive sensors. Signals are compensated, transformed and digitalized directly inside the sensor. Advantages: Operational limits: • Maximum measuring range of the relative humidity: 0-100%rh • Accuracy at 25°C : +/- 2.0 % • Extended temperature measuring range: -40....+120°C when fully calibrated with 5 Sensor-Checks SAL-SC • Very fast reaction time to big humidity changes • Air velocity : 0....40m/sec. (depending on type of filter) • Excellent mechanical robustness. • Basic accuracy of the DCC-1 : +/- 3.5% rh. • Protection functions against saturation (filters and heating) • Long term operation : 0......90% rh. • Minimized hysteresis • Measuring-hysteresis for control loops: ca. 1.0 % rh. Please note that the C-sensors must be operated within their specified limits. C-sensors are a little bit sensitive to chemical influences from the environment. Consequently a considerably higher drift of the humidity measurement may be the result. Therefore we recommend an additional chemical cell protection filter. HIC sensor (capacitive) HIC electronic sensor armature: Dimension : 160 x 13 mm Digital temperature & humidity measuring sensor incl. 1.5m cable with capacitive DCC-1 sensor. Fast reaction time, Weight : 100....800 g IP65 protection. Digital data transfer. Cable length up Measuremt. : rh: capacitive DCC-1 to 30 m possible. Protection cap with membrane filter temperature: NTC screwed onto the polycarbonate shaft. Connection : 5-pole cable and Accessories: 1 wall mounting clip & 1 duct mounting screen flange, incl. in the scope of delivery. Power : special Output : digital BIT interface Shaft length 100mm -> Please use Sensor Check Adapter PN 1107345 for the Protection : plastic membrane 111 9578 HIC-1x : SAL-SC calibration kit to ensure correct sealing (incl. 1.5m) filter 1,5 to 30m cable Oper. limits : 0.....100% (please order the right cable length) -40°…..+80°C HICS sensor (capacitive) HICS electronic sensor armature: Digital temperature & humidity measuring sensor Dimension : 310x20 mm with capacitive DCC-1 sensor. Fast reaction time, incl. 1.5m cable Weight : 200.....1000 g IP65 protection. Digital data transfer. Cable length up Measuremt. : rh: capacitive DCC-1 to 30 m possible. Protection cap with membrane filter temperature: NTC (CS-1) screwed onto the stainless steel shaft. Connection : 5-pole cable & shield Accessories: 2 wall mounting clips, incl. in the scope of Power : special Shaft length 160mm (incl. 1.5m) delivery. Output : digital BIT interface 111 9575 Protection : plastic membrane HICS-1x : 1,5 to 30m Option: duct mounting flange not incl. in the scope of filter Shaft length 310mm (incl. 1.5m) delivery. Oper. limits : 0.....100% 111 9558 HICS-2x:1.5 to 30m -40°…..+80°C cable (pls order the right cable length) HICH sensor (capacitive) HICH electronic sensor armature: Dimension : 310x20 mm Digital temperature & humidity measuring sensor Weight : 200.....1000 g with capacitive DCC-1 sensor. Special sensor Measuremt.: rh: capacitive DCC-1 armature made for extended temperature range temperature: NTC –40...+120°C. With 2 m temp. resistant silicone Connection : 5-pole cable and cable. The complete sensor probe can be mounted screen in the full temperature range. Shaft and SS-2 Power : special sintered filter are made of stainless steel. Including Output : digital BIT interface Shaft length 160mm cable and installation box. Protection : rustproof sintered 111 9580 HICH-11 : incl. 2m steel filter Pore size: 0.1μm w/o membrane silicon cable and installation box Oper. limits : 0.....100% Accessories: 1 Wall mounting flange & 1 installation box -40°…..+120°C for sensor wiring included in the scope of delivery included in the scope of Installation box for HICH sensor HICH cable installation box: delivery of a HICH-Sensor Part of delivery with HICH-sensor to HygroDat 100 Dimensions : 88 x 88 x 52 mm Installation box for professional wiring of a HICH Weight : ca. 150 g silicone sensor cable (for extended temp. range) to a Connectors : 2 x 6 clamps Protection grade: IP55 / IP65 screened 5 pole standard installation cable to the transmitter. This box has to be installed in a temp. Max. cable length 28 m between area of 0...+60°C. It is standard part of the HICH box and transmitter 111 9586 Installation box HICH sensor and is delivered together with it. Doc. 004701.00 General catalogue AIR 2014 page 24 / 34 HygroDat 100 - remote sensor units / sensor accessories Extension cable to C-sensor C-sensor standard cable for HIC, HICS and HICH: This cable shall be used as connection between the Cable type : LI YYS 5 x 0.25 installation box and the transmitter. It has 5 wires Conductors : 5 wires plus and an additional screen. The cables are available protection screen on order, from 1m up to 28m. Lengths : 1m up to.28 m 2 Colour : black 111 9585 Cable extension Cable type: Li YYS 5 x 0.25 mm , with screen. Temp. range : -20....+80°C to C-sensors HIA/HIC - accessories Wall mounting kit Wall mounting clip for HIA & HIC: Material : Polycarbonate A pair of wall mounting clips for an easy mounting of Weight : 15 g (each) HIA/HIC sensors to walls with M4 wood, plastic or metal screws. The clips can be reused. Quantity : 2 units -> Clamping range: 12....16 mm 110 7360 Wall mounting clips Clamping range: 12...16 mm Duct mounting kit Duct mounting kit for HIA & HIC: Flange dimensions : 60 x 20 mm Duct mounting flange (1 unit) including O-ring seal Weight : 30 g for HIA/HIC sensors. For an easy mounting in ducts or through walls or ceilings. The flange is fixed by 3 Clamping range : 10…14 mm screws and the 13 mm pass-through will stand an over-pressure of 3 bar before the seal leaks. The sensor can be removed at any time for recalibration. 111 5343 Duct mounting kit -> Clamping range: 10 .... 14 mm Sensor protection system SF-1 Sensor filter SF-1 for HIA & HIC: Filter dimensions : 45 x 13 mm Stainless steel, sintered filter protective cap for Weight : 15 g demanding industrial requirements to a HIA/HIC sensor. Intended primarily for use in environments Effectiveness: Mechanical where protection is needed from high air speeds protection against and/or high levels of pollution. Provides optimal particles larger than 0.2um “cellgard” mechanical protection of the sensor. Temperature range: –20 ...+80°C 110 7330 SF-1 filter Ø13mm -> The f ilter has a mesh size of 0.2um Sensor protection system AF-1 Sensor filter AF-1 for HIA & HIC: Filter dimensions : 45 x 13 mm Stainless steel metal web filter protective cap for the Weight : 10 g HIA/HIC sensors, incorporating an active charcoal Effectiveness : insert. Provides optimal protection of the Mechanical protection against particles measurement cell from corrosive gases and pollution larger than 25 um in industrial environments. Chemical protection : Nitrous oxide, 111 3675 AF-1 filter Ø13mm -> The f ilter has a mesh size of 25 um oil fog, fine dust, amine, ethylene. Temperature range: –20 ...+80°C Sensor protection system MF-1 Sensor filter MF-1 for HIA & HIC: Stainless steel metal web filter protective cap for the Filter dimensions : 45 x 13 mm HIA/HIC sensors, incorporating a membrane insert. Weight : 10 g Provides optimal protection of the measurement cell Effectiveness : from fine dust and dirt in industrial environments. Mechanical protection against particles larger than 0.2um -> The f ilter has a mesh size of 0.2um Temperature range: –20 ...+80°C 111 1018 MF-1 filter Ø13mm Doc. 004701.00 General catalogue AIR 2014 page 25 / 34 HygroDat 100 - sensor accessories Sensor protection system CP-1 Sensor cap CP-1 to HIA & HIC: Plastic protective cap for the HIA/HIC sensor, without any filter element. For rapid measurements in clean Cap dimensions : 45 x 13 mm air. It includes a protective grid without any filter Weight : 20 g function but providing basic mechanical protection. Effectiveness : limited Recommendation: for use when measurement speed is important mechanical and filter protection is not necessary. protection Temperature range: –20 ...+80°C 111 4745 CP-1 filter Ø13mm Sensor protection system STCF-1 Sensor filter STCF-1 f. HIA& HIC: Stainless steel protective cap incorporating a cellgard Filter dimensions: 45 x 13 mm membrane filter. For quick HIA/HIC sensor Weight : 20 g measurements in air. A robust model offering protection from larger objects in the air, but only Effectiveness : Cellgard, limited mechanical protection against dust. mechanical protection from Recommendation: for use when measurement speed is important particles larger and filtering is not necessary. than 0.2 um ->The filter has a 0.2 um mesh size Temperature range: –20 ...+80°C 111 7505 STCF-1 filter Ø13mm Weather shield for outdoor applications Weather shield for HIA & HIC: An effective protection from wind, rain, snow and Dimensions : 270 x 220 x 120 mm direct sunlight for the all HygroDat 100 EC sensors. Weight : 650 g Ideal for meteorological measurements in the range of –20°....+80°C (HIA) and –40°....+80°C (HIC) Include an cable screw for sensor fixation 13 … 20mm Include an cable screw sensor fixation for direct sensor installation if all 13…20mm sensors. Material : UV stabilised, thermoplastic The shield can be quickly and easily attached to a slats, painted 25.. 50 mm diameter post. steel construction The shield is delivered with all of the necessary 111 6812 Weather shield mounting materials. Doc. 004701.00 General catalogue AIR 2014 page 26 / 34 HygroDat 100 - sensor accessories HIS/HICS/HICH - accessories Wall mounting kit Wall mounting clips for HIS & HICS: A pair of wall mounting clips for easy mounting of Material : Polycarbonate HIS/HICS sensors to walls with M4 wood, plastic or Weight : 15 g ( each ) metal screws. The clips can be reused. Quantity : 2 units. -> Clamping range : 18.5.....22.5 mm 111 7588 Wall mounting clips Clamping range: 18.5...22.5 mm Wall mounting kit 2 Clamping flange for HIS, HICS & HICH: Wall mounting clamping flange for a very stable Material : Polyamide /steel clamping of a HIS/HICS/HICH sensor to a wall or resistant from inside surface of a duct. The flange may be screwed Dimensions : 80x30x47 mm or welded to the attaching surface. Suitable for extended temperature range –40…+120°C. Weight : 150 g 111 7992 Clamping range : 19...26 mm Clamping flange -> Clamping range 19....26 mm Extended temperature range: –40 ... +120°C Duct mounting kit Duct mounting kit for HIS, HICS & HICH: Duct mounting flange for easy, sealed mounting in Material : Polycarbonate/rubber ducts or through walls or ceilings. The flange is fixed resistant from by 3 screws and O-rings are provided. The 20 mm Flange dimensions : 60 x 20 mm pass-through will stand an over-pressure of 5 bar before the seal leaks. The sensor can be removed at Weight : 100 g any time for recalibration or testing. Clamping range : 19…24 mm 111 7538 Duct mounting flange -> Clamping range: 19 .... 24 mm Temperature range: –20 ...+80°C Sensor protection system SS-1 Sensor filter SS-1 for HIS, HICS : Dimensions Filter : 50 x 20 mm Stainless steel, sintered filter protective cap for Weight : 35 g demanding industrial requirements to the HIS/HICS sensors. Intended primarily for use in environments Effectiveness: Mechanical where protection is needed against high air speeds protection against and/or high levels of pollution. Provides optimal particles larger mechanical protection of the sensor. than 0.2 um Temperature range: –20 ...+80°C 111 7183 SS-1 filter diam. 20mm -> The filter has a mesh size of 0.2 um For Sensor protection system SS-2 Sensor filter SS-2 for HICH: HICH Filter protection cap for HICH sensors. Made of Dimension: 50 x 20 mm sensors stainless, sintered steel. Intended primarily for use in Weight : 30 g environments where protection is needed against Effectiveness : Mech. protection down high air speeds and/or high levels of pollution. to particle size 10 um Provides optimal mechanical protection of the Extended temperature range: sensor. No splash water protection! –40 ... +120°C 111 9600 SS-2 filter diam. 20mm -> The sinter filter has a mesh size of 10 um Sensor protection system TS-1 Sensor filter TS-1 for HIS & HICS: Metal web filter with Cellgard Filter dimensions : 50 x 20 mm Stainless steel metal web filter protective cap for the Weight : 30 g HIS/HICS sensors, incorporating a membrane insert. Effectiveness: Mechanical Provides optimal protection of the measurement cell protection against against pollution in industrial environments. particles larger than 0.2 um -> The filter has a mesh size of 0.2 um 111 7524 TS-1 filter diam. 20mm Temperature range: –20 ...+80°C Doc. 004701.00 General catalogue AIR 2014 page 27 / 34 HygroDat 100 - sensor accessories Sensor protection system TS-2 Sensor filter TS-2 for HICH : Mesh filter without membrane, for extended temp.range Dimension : 50 x 20 mm Stainless steel metal mesh filter protection cap Weight : 30g without membrane for HICH sensors. Good protection of the measuring cells against mechanical Effectiveness: Mech. protection down to particle size 25 um pollution in industrial environments. Extended temperature range : -> The filter has a mesh size of 25um –40 ... +120°C 111 9597 TS-2 filter diam. 20mm Sensor protection system AS-1 Sensor filter AS-1 for HIS&HICS: Metal web filter Filter dimensions : 50 x 20 mm Weight : 30g Stainless steel metal web filter protective cap for HIS/HICS sensors, incorporating an active charcoal Effectiveness: Mechanical insert. Provides optimal protection of the protection against measurement cell from corrosive gases and pollution particles larger in an industrial environment. than 10um Chemical protection : Nitrous oxide, -> The filter has a mesh size of 10um oil fog, fine dust, amine, ethylene 111 7525 AS-1 filter diam. 20mm Temperature range: –20 ...+80°C Sensor protection system AR-1 Redox Sensor filter AR-1 “Redox” for HIS & HICS : Stainless steel, metal web filter protective cap for Filter dimensions : 50 x 20 mm HIS/HICS sensors. The built-in Redox granulate filter provides optimal protection from corrosive gases in Weight : 35g the pharmaceutical industry. Effectiveness: Mechanical protection against -> The filter has a mesh size of 12um particles larger than 12um 111 8965 AR-1 “Redox” filter Temperature range: –20 ...+80°C Weather shield for outdoor applications Weather shield for HIS & HICS : An effective protection against wind, rain, snow and Dimensions : 270 x 220 x 120 mm direct sunlight for the HIS/HICS sensors. Ideal for Weight : 650 g meteorological measurements in the range of –20°....+80°C (HIS) and –40°....+80°C (HICS) Material : UV stabilized, thermoplastic The shield can be quickly and easily mounted to a slats, painted 25.. 50 mm diameter post. steel construction ->The shield is delivered with all of the necessary 111 6812 Weather shield mounting materials. included in the scope of delivery of Installation box to HICH sensor HICH cable installation box: HICH sensor Part of delivery with HICH-sensor to HygroDat 100 Dimensions : 88 x 88 x 52 mm Installation box for professional wiring of a HICH Weight : ca. 150 g silicone sensor cable (for extended temp. range) to a Connectors : 2 x 6 clamps Protection grade: IP55 / IP65 screened 5 pole standard installation cable to the transmitter. This box has to be installed in a temp. Max. cable length 28 m between area of 0...+60°C. It is standard part of the HICH box and transmitter 111 9586 Installation box sensor and is delivered together with it. Doc. 004701.00 General catalogue AIR 2014 page 28 / 34 HygroDat 100 - sensor accessories Sensor-Checks SAL-SC (rh standards) Humidity values in the temperature range 15° .... 30°C: Humidity standards based on saturated salt solutions 11.3 ..... 11.3% rF / 15....30°C in plastic cylinders with moisture permeable 33.3 ..... 32.4% rF / 15....30°C membranes. Each salt is delivered in a well-sealed 55.9 ..... 51.4% rF / 15....30°C box. Sensor Checks SC are obtainable for the 60.7 ..... 56.0% rF / 15....30°C following values (at 25°C) : 75.6 ..... 75.1% rF / 15....30°C 111 0885 -> SAL-SC 11 85.9 ..... 83.6% rF / 15....30°C 111 0855 90.9 ..... 89.9% rF / 15....30°C -> SAL-SC 33 11.3 % rh colour white 75.3 % rh colour purple 97.9 ..... 97.0% rF / 15....30°C 111 0857 -> SAL-SC 53 32.8 % rh colour blue 84.3 % rh colour white 260 0219 -> SAL-SC 58 52.9 % rh colour green 90.1 % rh colour white 111 0859 57.6 % rh colour white 97.3 % rh colour yellow -> SAL-SC 75 The precision corresponds to the 251 8965 Greenspan Report 1977 -> SAL-SC 84 typically +/- 0.3 % rh 111 0896 -> SAL-SC 90 Important: please consult the operation manual of 251 8966 your instrument to see which points can be Weight : 90 g -> SAL-SC 97 calibrated. Other SAL-SC can be used for verification. Sensor-Checks SAL-SC Internationally accredited laboratory with European certificate Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SAL-SC are obtainable for the All Novasina humidity standards following values (at 25°C) : 111 1044 can also be supplied with an -> SAL-SC 11 C 11.3 % rh colour white internationally recognised certificate 111 1037 -> SAL-SC 33 C 32.8 % rh colour blue from an accredited European 111 1040 -> SAL-SC 53 C 52.9 % rh colour green laboratory (UKAS England). 111 1035 -> SAL-SC 75 C 75.3 % rh colour purple 111 1032 Weight : 90 g -> SAL-SC 90 C 90.1 % rh colour white Internationally accredited HygroDat 100 certification laboratory by an accredited European laboratory (UKAS) A UKAS-laboratory certifies the instrument at two or more humidity and several temperature values if required. Certified instruments can be Prices on pricelist for air products supplied. Set with 5 Sensor-Checks SAL-SC Case with all 5 Sensor Checks from 11 to 90%rh: Humidity standards based on saturated salt solutions Humidity values in the temperature in plastic cylinders with moisture permeable range 15°... 30°C : membranes. Each salt is delivered in a well-sealed 11.3 ..... 11.3% rh box. Sensor Checks SAL-SC are obtainable for the 33.3 ..... 32.4% rh following values (at 25°C) : 55.9 ..... 51.4% rh 11.3 % rh colour white 75.6 ..... 75.1% rh 32.8 % rh colour blue 90.9 ..... 89.9% rh 52.9 % rh colour green The precision corresponds to the 75.3 % rh colour purple Greenspan Report 1977 111 7847 Check set (standard) 90.1 % rh colour white typically +/- 0.3 % rh 111 7841 Empty case for set Weight : 900 g SAL-SC Sensor check adapter CH CH adapter to SAL-SC salts for sensors with diameter 13 mm: for sensors with diameter 13 mm This adapter is needed for calibration of a system Dimensions : 30 x 13 mm with sensor diameter 13 mm. It ensures an airtight Material : Polycarbonate, fixation of a SAL-SC check to the sensor top rubber (measurement cell area). It reduces the diameter of Weight : 5 g 20 mm to 13 mm and ensures an airtight seal. 110 7345 Adapter CH -> The adapter should be first mounted on the sensor top and then putted the SAL-SC check on it. Both seals should be carefully checked, leaks will bias the calibration. Doc. 004701.00 General catalogue AIR 2014 page 29 / 34 HygroDat 100 - sensor accessories / spare parts Thermal insulation styrofoam box Styrofoam box for the SC check: For the SAL-SC sensor checks Dimensions : 100 x 65 x 50 mm A styrofoam box providing optimal insulation and Weight : 10 g temperature stabilisation of a SAL-SC check during Material : thermal insulating the calibration procedure. Consisting of two half- styrofoam PPE covers for simple temporary mounting. 111 1302 Styrofoam -> Can be used together with the SAL-SC calibration kit for optimal box for SC thermal protection during calibration Spare parts Set of plugs Transmitter plug set: for the HygroDat 100 24V Sensor plug : 5-Pol. 3.72 mm AO-plug : 5-Pol. 5.08 mm A set of three different replacement plugs for the Power plug : 3-Pol. 5.08 mm HygroDat 100 transmitter. Weight : 15 g Consists of: - sensor plug 5 pin screw system - 5 pin screw system 111 8973 Quantity : Set of 3 plugs plug set E-Sensor - power plug 2 pin screw system Standard filter CF-1 Sensor filter CF-1 for HIA & HIC : Plastic protective cap with a membrane filter element Filter dimensions : 45 x 13 mm for the use of HIA/HIC sensors in standard HVAC Weight : 15 g applications. Limited mechanical protection and Effectiveness : Mech. protection, filtering. small particles, water drops Recommendation: A protective cap for general protection in Temperature range: –20 ...+80°C relatively clean environments and air speeds 110 7355 CF-1 HIA, HIC filter of less than 5 m/s. -> This filter is included with theHIA/ HIC sensor. The filter has a mesh size of 0.2 um Sensor protection system CS-1 Sensor filter CS-1 for HIS & HICS: Filter protective cap for the HIS/HICS sensor, Dimensions Filter : 50 x 20 mm incorporating a membrane filter protecting against Weight : 30 g water drops and small particles. Intended for fast measurements in normal air. Effectiveness : Mech. protection Provides only limited mechanical protection. 111 7523 CS-1 HIS,HICS filter Temperature range: –20 ...+80°C -> The filter has a mesh size of 0.2 um CC-1 measurement cell Resistive electrolytic humidity and temperature cell CC-1 measurement cell: High precision humidity and temp. measurement cell Dimensions : 35 x 7 x 6 mm for the range 6 ...100 % rh with integrated saturation Weight : 2 g protection and special NTC temp. measurement Type : Resistive electrolytic element for the range –20°....+80°C. measurement principle The measurement cell has a 2 x 3 pin plug and a Ranges : 6.....100% 111 3828 CC-1 normal special filter system to protect the sensing element. Electronic saturation protection -20°…..+80°C 111 6260 CC-1 silicon free Attention: Never touch the front part of the sensor with your finger or any other hard object. DCC-1 measurement cell DCC-1 measurement cell: Digital capacitive humidity and temperature Dimensions : 35 x 7 x 6 mm measurement cell Weight : 2 g Very robust humidity and temperature cell for the Hum. Measurement principle : range of 0...100 % rh with integrated NTC element : digital capacitive for temperature measurement in the range humidity cell -40°...+120°C. The DCC-1 cell has an 5 Pin female silicone chip based 111 9590 DCC-1 connector system. Ranges : 0.....100% digital capacitive Attention: Never touch the front part of the sensor with your -40°…..+120°C cell, silicone based finger or any other hard object. Doc. 004701.00 General catalogue AIR 2014 page 30 / 34 HygroDat 100 - spare parts Interface C/E Sensor RS-232 RS-232 to HygroDat 100: Optional part to HygroDat 100 Transmitters equipped with E-sensors Dimensions : 70 x 50 x 20mm Optional RS-232 interface for HygroDat 100 Weight : ca. 50 g transmitter with E-sensor (HIA, HIS). This interface Power supply: intern. from cover permits a serial data transfer to DDC, PLC or SPS electronics HD 100 controls etc.. RS-232 : standard level Inputs : 1 x E-sensor It can be also used for the connection of the 1 x C-sensor instrument to a PC running the Novasina NovaLog Max. cable length for serial 32 visualisation software. Interface : 15 m Data protocol : ASCII string 111 9621 RS-232 for HygroDat100 Note: This component is already built in as a standard in HygroDat 100 transmitters with C-sensors (HIC, HICS, HICH). Installation box for HICH sensors HICH cable installation box: Part of delivery with HICH-sensor to HygroDat 100 Dimensions : 88 x 88 x 52 mm Installation box for professional wiring of a HICH Weight : ca. 150 g silicone sensor cable (for extended temp. range) to a Connectors : 2 x 6 clamps Protection grade: IP55 / IP65 screened 5 pole standard installation cable to the transmitter. This box has to be installed in a temp. Max. cable length 28 m between area of 0...+60°C. It is standard part of the HICH box and transmitter 111 9586 Installation box sensor and is delivered together with it. Cable screw for sensor fixation on Cable screw for 13…20mm sensor: weather shield For all HIA / HIC / HIS / HICS / HICH sensors Dimensions : 100 x 35 mm Inner diameter : 13…20mm Sparte part mounting flange for fixation of all types of sensors (13…20mm diameter) to a weather shield. Weight : 280 g Enables the easy removal of the sensor at any time for test and recalibration. Material : UV stabilised, thermoplastic -> Suitable for all HygroDat 100 sensors with 100….310mm material with 260 0951 cable screw shaft lenght UNF threads Doc. 004701.00 General catalogue AIR 2014 page 31 / 34 CIC-Touch - touchscreen display CIC-Touch This multi display for clean room air parameters such as air humidity, temperature, differential pressure and particles allows to check at a glance the actual climatic parameters in clean rooms. The online data are provided by external sensors and/or contact relays. Besides the actual measurement value, which is shown with the respective unit (e.g. temperature, humidity etc.) and measurement location, also the backlight colour changes according to the actual status. Green colour for values within the threshold and red colour if the threshold is exceeded. The CIC-Touch display can be easily mounted in clean room walls without the need of any screws. The unit can be placed in a wall cavity, snapped in and fixed with clips, which are part of the display unit itself. Thanks to the consequent clean room suitable design, the installation depth is very low and hence the unit fits in all current clean room walls. The smooth front panel complies with the demands of clean room design, is therefore ideal to be cleaned and has no edges subject to be polluted by dust or any dirt. Another highlight of the CIC-Touch is the connectivity such as analogue/digital interfaces, contact relays, ethernet, USB, Modbus, RS-232, RS-485 and a SD card. The CIC-Touch can be easily connected to any external sensor and also integrated in existing monitoring systems. The configuration is performed via the intuitive operation and configuration menu. The CIC-Touch can also be factory configured for specific OEM applications. Applications: Your advantages: • Clean rooms • Semi-flush with the wall, no sharp edges, front • Isolators panel only 2 mm thickness • Laminar flow benches • Easy to clean, flat and smooth surfaces • Operating rooms • Low installation depth and ideal for integration • Laboratories, calibration rooms in all current clean room walls • Specific OEM solutions • Snap-in mounting without any screws Industries: • Display of up to 4 parameters at the same time • Semiconductor • Status display with status backlight colour • Pharmaceutical • Easy configuration by intuitive menu • Hospitals • OEM • Several integrated communication interfaces CIC-Touch touchscreen display Specifications: Display: graphical display 3,5“ TFT Recommended ambient sensors to be connected: display 70x52mm Panel: 150 x 120 mm (H2O2 res.) Air humidity and temperature: • Mounting H 127 x W 107 x D 50mm. HygroDat 100 (this catalogue on page 21) dimension: incl. connectors • HygroMaxx S/R/M (this catalogue on page 10) Power • TempMaxx (this catalogue on page 17) supply: 24 V AC/DC Inputs: 4 x digital inputs Differential pressure: 4 x analogue inputs • Pascal-ST/Z (dP catalogue on page 8) Outputs: 2 x relay contacts 230V • PascalMaxx (dP catalogue on page 12) Digital ethernet interfaces: Modbus (RS-485) Remark: CIC-Touch is an universal display and any USB: standard PC compatible sensor can be connected, it can also be used for 260 0941 CIC-Touch display installation in existing sensor networks. Doc. 004701.00 General catalogue AIR 2014 page 32 / 34 Product overview - Novasina RH/T transmitters Instrument Parameter Industry Applications Main features HygroDat 100 RH/T • Pharmaceutical • Clean Rooms • High accuracy • Textile/Paper • Operating rooms • Highest repeatability • Chemical • Combustion processes (gas • Low hysteresis • Medical turbines) • Fast response time • Health Care • Drying processes • Climate parameter • Semiconductor • Meteorological stations calculation • Power Plants • Demanding HVAC controls • 2 scalable/adjustable • Building industry • Painting processes analogue outputs • Food • Food process and storage • RS-232 interface • • • Fieldbus interface Agriculture Green houses with high RH levels • 5 point RH calibration • Mining and tunnel building • Sensor protection filters • Calibration labs for aggressive air • Specific OEM applications • Password protection HygroMaxx RH/T • Building Industry • Generic HVAC installation • Good accuracy for S/R/M • Pharmaceutical • Packaging industry HVAC applications • Agriculture • Laboratories (food, pharma) • Big clear display • Medical • Storages • 2 scalable analogue • Food • Archives, museums outputs • Printing processes • Calibration at 3 points RH & 1 point T • Intuitive menu structure • Easy to start-up and mounting • 3 models for room, duct and remote use • Password protection TempMaxx T • Building Industry • Generic HVAC installation • High flexibility in • Pharmaceutical • Packaging industry connections of external • Agriculture • Laboratories (food, pharma) probes 2-, 3-,4-wire (PT, • Medical • Storages Ni, NTC) • Food • Archives, museums • Big clear display • Printing processes • 1 scalable analogue output • 1 relay contact • Calibration at 2 points T • Intuitive menu structure • Easy to start-up and mounting • Password protection StatMaxx RH/T • Building Industry • Generic HVAC installation • Good accuracy for S/R/M • Pharmaceutical • Monitoring systems HVAC applications • Agriculture • Packaging industry • Big clear display • Medical • QA-laboratories • 1 relay contact • Food • Laboratories (food, pharma) • UMB Bus interface • Storages • Calibration at 3 points • Archives, museums RH & 1 point T • Printing processes • Intuitive menu structure • Easy to start-up and mounting • Password protection Doc. 004701.00 General catalogue AIR 2014 page 33 / 34 Product overview - Novasina data loggers / handhelds / displays Instrument Parameter Industry Applications Main features HygroGuard 30 RH/T • HVAC • Generic HVAC installation • Battery powered > 1 year • Pharmaceutical • QA-laboratories life time • Building Industry • Container shipping • Big clear LCDisplay • Food • Storages • Big internal memory • Hospitals • Archives, museums (3'200'000 data points) • Semiconductor • Data storage and • Logistics visualisation software included with data cable • USB power supply as option • Calculation of dew point / absolute humidity DataLog 30 RH/T • HVAC • Generic HVAC installation • Battery powered > 1 year various • Pharmaceutical • Monitoring systems life time • Building Industry • Packaging industry • Big clear LCDisplay • Food • QA-laboratories • Big internal memory • Hospitals • Laboratories (food, pharma) (3'200'000 data points) • Semiconductor • Storages • Data storage and • Logistics • Archives visualisation software • Museums included with data cable • Printing processes • 2 analogue interfaces (voltage/current) • 8 UMB bus interfaces • USB power supply as option • Calculation of dew point / absolute humidity ClimaLog 30 RH/T/ • HVAC • Generic HVAC installation • Battery powered > 1 year absolute • Pharmaceutical • QA-laboratories life time air pressure • Building Industry • Container shipping • Big clear LCDisplay • Food • Storages • Big internal memory • Hospitals • Archives (3'200'000 data points) • Semiconductor • Museums • Data storage and • Logistics visualization software included with data cable • USB power supply as option • Calculation of dew point / absolute humidity HygroMate RH/T/ • HVAC • Generic HVAC installation • Battery powered dew point • Pharmaceutical • QA-laboratories • Big clear LCDisplay temperature • Building Industry • Storages • RH calibration at 2 points • Hospitals • Archives and temperature • Semiconductor • Museums calibration at 1 point • Logistics • Easy operation with thumb wheel • Backlight and AutoOff function CIC-Touch Universal • Pharmaceutical • Clean rooms • Semi-flush mounting touchscreen • Semiconductor • Isolators • Easy to clean display • Chemical • Laminar flow benches • Low installation depth • Medical • Operating rooms • Snap-in mounting • Health Care • Laboratories, calibration • Display of up to 4 • Hospitals rooms parameters • Specific OEM solutions • Status display with status backlight colour • Easy configuration • Several integrated communication interfaces Doc. 004701.00 General catalogue AIR 2014 page 34 / 34 Document Outline HygroMate HygroMate measurement instrument HygroMate hand measurement instrument HygroMate accessories Table or wall holder Protective bag for the HygroMate Protective case for the HygroMate Sensor-Checks SAL-SC (rh standards) Set with 5 Sensor-Checks SAL-SC SAL-SC Sensor check adapter CH Sintered filter for the HygroMate Spare parts for HygroMate Metal web filter for the HygroMate Capacitive measurement cell HygroGuard 10 or 20 HygroGuard 30 / CimaLog 30 / DataLog 30 HygroGuard 30 Data logger system ClimaLog 30 Data logger system DataLog 30 Data logger system Accessories HygroGuard 30 DKD calibration certificate ClimaLog 30 DKD calibration certificate USB power supply StatMaxx S StatMaxx R StatMaxx M Duct mounting kit LOG-PU power unit and wiring UMB-bus connector Data logger line - accessories / options Data logger line - options / installation example HygroMaxx HVAC line - relative humidity/temperature transmitters HygroMaxx instrument types HygroMaxx S / R / M HygroMaxx SHumidity/Temperature measurement instruments for rooms HygroMaxx R HygroMaxx M HVAC line - relative humidity/temperature hygrostats StatMaxx hygrostats / accessories StatMaxx S / R / M StatMaxx S StatMaxx R StatMaxx M STAT-PU power unit Accessories for Duct mounting kit Wall mounting kit 13 mm Sensor-Checks SAL-SC (rh standards) Sensor-Checks SAL-SCwith European certificate Set with 5 Sensor-Checks SAL-SC SAL-SC Sensor check adapter CH Thermal insulation styrofoam box Spare parts for Spare plug set - HygroMaxx Spare plug set - StatMaxx Spare room sensor the sensor Spare duct sensor Remote sensor for HygroMaxx M Remote sensor for StatMaxx M Housing bottom External power supply 90...264VAC/EUR Ext. power supply 90...264VAC / US/JP Factory calibration UKAS certification For M versions, the remote sensor has to be sent together with the corresponding transmitter. TempMaxx HVAC line - temperature transmitters & thermostats TempMaxx - transmitters & thermostats / accessories TempMaxx TempMaxx Temperature transducer for resistor sensors Accessories NTC Thermistor -20 ... +80°C : PT 100 Cable duct sensor -50...+200°C PT 100 Air-cable sensor -35...+105°C PT 100 Air-duct sensor -30...+180°C PT 1000 Air-room sensor -35...+70°C Other temperature sensors on request TempMaxx - accessories TempMaxx - options / spare parts Options External power supply 90...264VAC/EUR Ext. power supply 90...264 VAC / US/JP Spare parts Spare connector set to TempMaxx Housing lower half for TempMaxx HygroDat 100 PROCESS line - relative humidity/temperature transmitters HygroDat 100 EC - transmitters HygroDat 100 Polycarbonate HygroDat 100 PC-Software NOVALOG 32 PC/Laptop converter USB-RS232 E-sensors for HygroDat 100 EC HIA sensor (electrolytic) HIS sensor (electrolytic) Interface C/E Sensor RS-232 C-sensors for HygroDat 100 EC HIC sensor (capacitive) HICS sensor (capacitive) HICH sensor (capacitive) Installation box for HICH sensor Extension cable to C-sensor HIA/HIC - accessories Wall mounting kit Duct mounting kit Sensor protection system SF-1 Sensor protection system AF-1 Sensor protection system MF-1 Sensor protection system CP-1 Sensor protection system STCF-1 Weather shield for outdoor applications HIS/HICS/HICH - accessories Wall mounting kit Wall mounting kit 2 Duct mounting kit Sensor protection system SS-1 Sensor protection system SS-2 Sensor protection system TS-1 Sensor protection system TS-2 Sensor protection system AS-1 Sensor protection system AR-1 Redox Weather shield for outdoor applications Installation box to HICH sensor Sensor-Checks SAL-SC (rh standards) Sensor-Checks SAL-SCwith European certificate HygroDat 100 certification Set with 5 Sensor-Checks SAL-SC SAL-SC Sensor check adapter CH Thermal insulation styrofoam box Spare parts Set of plugs for the HygroDat 100 24V Standard filter CF-1 Sensor protection system CS-1 CC-1 measurement cell DCC-1 measurement cell Interface C/E Sensor RS-232 Optional part to HygroDat 100 Transmitters equipped with E-sensors Installation box for HICH sensors Cable screw for sensor fixation on weather shield CIC-Touch touchscreen display