6000 Precision Headspace Analysers Advanced Products for Measurement of O2 and CO2 in MAP/CAP Headspace Atmospheres Applications Fresh Meat Cooked Meat Vegetables Salads Bakery Snack Foods Ready Meals Fish Pharmaceutical Vials Pharmaceutical Packaging Features & Benefits Easy to set up and use Set tests for pass or fail Intuitive menu Printer option Auto calibrate Computer software option Systech Illinois is recognised worldwide for Precision flowmeter its line of precision trace oxygen and The Systech Illinois 6000 range offers carbon dioxide analysers. Precision flowmeter provides visual Software three different models to confirmation of sample flow. Unlike accommodate your oxygen and The Systech Illinois 6000 headspace warning lights, users can monitor system User friendly software parameters are carbon dioxide measurements. analysers offer high levels of performance performance and resolve potential easy to enter and can be secured technology and operator ease to fulfill the problems before they occur. against accidental change. The compact enclosure maximizes latest industry demands for accuracy and space on carts and table tops. reliability. Display hold Seamless cover design and polycarbonate operator‘s panel sheds These highly advanced instruments are Locks most recent high or low spills and resists most chemicals and equipped with integral sampling systems, concentration value. Bright, large character solvents. unique miniature zirconia and infrared display is easy to read in any lighting sensors, and microprocessor control to condition. Status lights indicate mode of deliver the most accurate and repeatable operation. performance possible. One touch automated calibration and product analysis Timed Analysis make these analysers easy to use. Automated sampling 6500 measures oxygen levels only Timed, automatic analysis is provided at the Rugged and compact epoxy clad cabinetry, touch of a button. Programmable sampling Automated package sampling is easy. seamless operator’s console and duration and data integration make these Insert the sampling needle into the no-compromise engineering make these among the most advanced headspace package and press analyse. The instruments ideal for both the laboratory or analysers available. instrument does the rest; extracting the demanding climate of the production the sample, analysing sensor output floor. Autocalibration and holding the results for viewing on the bright autoranging display. With a single button the instrument self RS232 output calibrates in just 30 seconds using ambient air. Samples injected directly RS232 output prints product description and sample data to 40 column thermal desktop printer for hard copy of calibration Headspace samples can be injected directly into the instrument when 6600 measures both oxygen and and test results. Prints test “Fail” according automated sampling is not practical. carbon dioxide concentrations. to user defined alarm settings. Accessories The can piercing station is perfect for rigid packaging and has proven to be stable and reliable in hundreds of demanding applications. 6700 measures carbon dioxide only Unique sensors Analysis of small sample volumes. Sample probe Response is typically less than five seconds for oxygen and ten seconds for The robust sample probe is designed to carbon dioxide. Internal microprocessor accept standard luer accessories and manages calibration, autoranging, pump includes easily replaced needles and speed and duration and many other particulate filters. With a convenient sample functions to ensure consistent, probe holder to prevent needle Can Piercing Station error-free results. contamination and sample line damage. Principle of operation Oxygen Carbon Dioxide The oxygen detector utilises a high purity, This sensor integrates a solid state infrared stabilised zirconia ceramic and platinum source and detector into a single high sensor maintained within a high performance assembly. Narrow wavelength temperature environment. The sensor filtering and strict temperature produces a log output which is converted compensation ensure that only carbon and linearised to yield a digital readout dioxide is measured, even within complex directly proportional to a sample’s oxygen gas mixtures. Precise signal conditioning content. and microprocessor control provide direct digital indication of CO2 concentrations. Technical Specifications Oxygen Range Autoranging from 0.001 to 100% (models 6500 & 6600) Carbon Dioxide Range Autoranging from 0.1 to 100% (models 6600 & 6700) Displays Bright 4 Digit LED, Display Hold, Analyse, and Calibration Status Indicators Response Time <5 seconds (O2), <10 seconds (CO2) Accuracy: Oxygen 10 to 100%, 0.2% absolute (max 2% of reading) and ±1 on the last digit. 1 to 9.99%, 0.02% absolute (max 2% of reading) and ±1 on the last digit. 0 to 0.999%, 0.005 % absolute and ±1 on the last digit. Accuracy CO2 ±2% FSD Ambient Temperature +5 to +40°C Internal Sample Pump Processor Controlled Diaphragm Type Syringe Injection Via Male Luer Syringe Adaptor (supplied) Enclosure Epoxy Coated Steel, Polycarbonate Operators Panel Dimensions 305mm W x 254mm D x 152mm H Weight 5.3 kg Options Computer Interface RS232 Port for Computer/Data Printer Rigid Pack Sampler Extracts samples from cans, jars, bottles, etc. Includes all necessary fittings and supplies. Compact Printer 40 Column Thermal Desktop Printer Power Requirements Mains power 110 / 220 VAC, 50 / 60 Hz. 100 Watt Maximum Systech Illinois have over 25 years experience of providing analysis solutions for a wide range of industries. From our manufacturing plants in the UK and U.S we produce gas analysers for industrial process industries, headspace analysers for monitoring gas flushing of food products, and our range of permeation analysers. Systech Instruments Ltd (UK) Illinois Instruments, Inc (U.S) Illinois Instruments (Thailand) Systech Illinois (China) 17 Thame Park Business Centre, 2401 Hiller Ridge Road 6th fl Nopnarong Bldg No7 Room 519, No.3 FuCheng Building Wenman Road, Johnsburg, Illinois 60051 Ladprao23, Jatujak, Bangkok 10900 No. 900 Quyang Rd, Hongkou district, Thame, Oxfordshire OX9 3XA U.S.A Thailand Shanghai, China 200434 Tel: +44 (0)1844 216838 Tel: +1 815 344 6212 Tel: +66 (0)2938 0798 Tel: +86 21 65533022 Fax: +44 (0)1844 217220 Fax: +1 815 344 6332 Fax: +66 (0)2938 1058 Fax: +86 21 65539651 E-mail: advice@systech.co.uk E-mail: sales@illinoisinstruments.com E-mail: mai@illinoisinstruments.com Email: info@systechillinois.cn www.systechillinois.com www.systechillinois.com www.systechillinois.com www.systechillinois.cn Systech Illinois reserve the right to change specifications without notice. 09/2010