Portamap For Quality Control checking of modified atmosphere in food products Applications Fish Salads Vegetables Bakery Fresh & Cooked Meat Snack Foods Ready Meals Pharmaceutical Vials, Ampoules and Packaging Features & Benefits Fully portable Maintenance free Easy to use and calibrate Replaceable oxygen cell Robust construction Quick response The Portamap portable gas analyser is Unlike many electrochemical cells, the specifically designed to test for the Systech Illinois cell is unaffected by carbon presence of oxygen and carbon dioxide in dioxide. food packaged under modified and controlled atmospheres. Testing is done by simply inserting the needle probe into the package for test and The instrument is simple to use and is pressing a switch on the front panel to start powered by maintenance free batteries the internal sample pump. The analysis of which can be recharged by simply the gas is then shown on the LCD display. connecting the analyser to the mains Periodic calibration can be carried out using supply. air or a calibration gas. The Portamap utilises the Systech Illinois The Portamap is robust in construction and electrochemical fuel cell for oxygen is unaffected by vibration or operating analysis and an infra red sensor for carbon position. It is not flow sensitive or affected by dioxide analysis. changes in atmospheric pressure. Portamap 1 oxygen and Portmap 2 oxygen & carbon dioxide Portamap 1 Portamap 2 IP40, ABS IP40, ABS with tilting carry handle with tilting carry handle Portable or bench mounted Portable or bench mounted 262W x 102H x 25D (mm), weight 3.2 kg 262W x 102H x 25D (mm), weight 4.7 kg Technical Specifications Ranges Oxygen 0-100% Carbon Dioxide 0-100% Resolution 0.1% of scale Accuracy: Oxygen ±0.1%of calibrated value Carbon Dioxide ± 2% of reading Response time 90% of reading in 20 seconds Measuring cell type: Oxygen Electrochemical fuel cell Carbon Dioxide Dual infra-red detector Oxygen Cell life Use Dependent (typically three years at 21%) Operating conditions Sample inlet pressure Ambient - internal pump as standard Sample temperature 0 to 40°C Ambient temperature 0 to 40°C Sample connections Needle probe Unsuitable gases Not applicable Power Requirements Power supply Maintenance free rechargeable battery 230 or 115V ±5%, 50/60Hz mains supply Battery life Portamap 1 - 24 hours continuous use Portamap 2 - 12 hours continuous use Recharge time 8 hours Display type LCD digital meter Options Probes Various sampling probes to suit application, needles, filters, septas Can piercing station Carry case Systech Illinois have over 25 years experience of providing analysis solutions for a wide range of industries. From our manufacturing plants in the UK and U.S we produce gas analysers for industrial process industries, headspace analysers for monitoring gas flushing of food products and our range of permeation analysers. Systech Instruments Ltd (UK) Illinois Instruments, Inc (U.S) Illinois Instruments (Thailand) Systech Illinois (China) 17 Thame Park Business Centre, 2401 Hiller Ridge Road 6th fl Nopnarong Bldg No7 Room 519, No.3 FuCheng Building Wenman Road, Johnsburg, Illinois 60051 Ladprao23, Jatujak, Bangkok 10900 No. 900 Quyang Rd, Hongkou district, Thame, Oxfordshire OX9 3XA U.S.A Thailand Shanghai, China 200434 Tel: +44 (0)1844 216838 Tel: +1 815 344 6212 Tel: +66 (0)2938 0798 Tel: +86 21 65533022 Fax: +44 (0)1844 217220 Fax: +1 815 344 6332 Fax: +66 (0)2938 1058 Fax: +86 21 65539651 E-mail: advice@systech.co.uk E-mail: sales@illinoisinstruments.com E-mail: mai@illinoisinstruments.com Email: info@systechillinois.cn www.systechillinois.com www.systechillinois.com www.systechillinois.com www.systechillinois.cn Systech Illinois reserve the right to change specifications without notice. 09/2010