SMARTCHEM 140 DIRECT READ DISCRETE ANALYZER FOR SIMPLE AND AUTOMATED CHEMISTRIES SMARTCHEM 140 FULLY AUTOMATED, DIRECT READ, THE ADVANTAGES DISCRETE ANALYZER TO MAXIMIZE OF DIRECT READ PRODUCTIVITY FOR ROUTINE AND DISCRETE ANALYSIS SPECIAL CHEMISTRIES, UP TO 140 TESTS/HOUR • Each reaction takes place in its own optical cuvette • True sample blanking performed directly in each cuvette • No flow cells • No baseline stabilization • No manual manifold changeover • No excessive reagent consumption • Automatic reagent blanking to evaluate reagent quality • Pre and Post dilution of samples and calibration standards • Automatic spike preparation • Automatic method changeover • Analyze samples in “batch” mode or “random” mode Based on widely used Smartchem 200 technology, the Smartchem 140 was designed for smaller laboratories in pursuit of efficiency and data quality. The Smartchem 140 combines the latest technology in DIRECT READ : discrete analysis with an innovative, unique design that guarantees accurate and reproducible results. MORE SIMPLICITY & SECURITY The Smartchem 140 is the first discrete analyzer to utilize The Smartchem 140 uses direct read photometry the Cuvette Quality Assurance System, performing an utilizing a true discrete, direct read measurement integrated QC check of each cuvette prior to use. In addition system and reusable, high purity synthetic optical to automated analysis the Smartchem 140 offers automated cuvette system eliminating compromised sample system Quality Control. measurement. The Smartchem 140 is also the first discrete analyzer to utilize a patented, dedicated sample prep module for the SMARTWASH : ELIMINATE CARRYOVER determination of NOx by Cadmium reduction. Designed for DURING SAMPLING multi-tasking and high throughput rates, the NOx module also provides automated cadmium regeneration. • Level sensor makes probe washing easy, with a standard 2mm immersion depth • Potential contaminants go the way they need to flow – out of the sample probe! INTERACTIVE GRAPHICAL “DASHBOARD” • Three stage process: clean the inside of the probe, PROVIDES A USER-FRIENDLY INTERFACE: clean the washing well, then clean the outside of the probe SELECT METHOD(S) AND TYPE IN SAMPLE IDS • Optical integrity of each cuvette quantitatively verified before each use FOLLOW THE DASHBOARD AND PLACE • Provides an infinite number of reaction vessels for analysis THE SAMPLES, REAGENTS, AND STOCK • Economical & environmentally friendly : long lasting STANDARD IN THE AUTOSAMPLER cuvettes, minimize hazardous waste and solid wastes START ANALYSIS WITH A SIMPLE CLICK, ALL ANALYTICAL PROCEDURES FROM WORKING SAMPLE LOADING STANDARD DILUTION TO SAMPLE ANALYSIS, • 4 universal, separate racks for continuous loading CUVETTE WASHING AND SYSTEM QC , ARE of samples, calibrators and controls FULLY AUTOMATED AND DO NOT NEED • Up to 140 tests/hour ANY OPERATOR ACTION Washing station Smartwash Micro pipettor-dilutor Cadmium module for Long-life cuvettes with integrated Nitrate analysis Cuvette Quality Assurance System FILTER WHEEL USER FRIENDLY • 12 optical filters (9 on board), ranging from 340nm to 880 nm SMARTSTART • Others filters optionally available SOFTWARE COMPUTER CONTROLLED MICRO PIPETTOR • Accurate and precise dispensing of all liquids The Smartchem 140 operating software runs under Windows 7 • Probe cleaned after every liquid contact - prevents cross to 10. Its bright graphical user interface simplifies routine work contamination and carryover and offers the operator a concise guide through the operating • Microliter reagent and sample consumption functions. • Liquid level sensor provides warnings for low reagent and sample levels NEW SOFTWARE MAIN FEATURES NITRATE/NITRITE MODULE • Automatic start-up • Automated cadmium coil regeneration for Nitrate & Nitrite • Automatic shutdown analysis, complies with US EPA Method # 353.2 • Handheld barcode reader for reagents & samples • Patented design • Addition of new sample or method to a sample during the run PHOTOMETER • Accurate estimation of completion of analysis • Calibration points recalculation • High resolution, dual beam digital detector • Last accepted calibration overlay • Expanded absorbance range to 2.500 ABS • Pre-dilution • 5 detection modes: endpoint, fixed time, differential, • Standard curves bichromatic, and kinetic • Computer controlled micro pipettor • EPA NELAC compliant • Real-time presentation of sample and reagent status TECHNICAL SPECIFICATIONS DESCRIPTION Fully automated, direct read, bench top, Discrete analyzer ASSAY TYPE End Point, Kinetic, Differential, Bi chromatic assays, 2 fixed times ON-BOARD REAGENTS - 24 multi-use positions (reagents, diluents, spike solutions and QC samples) - 12 positions for stock calibration standards SAMPLES LOADING 4 racks for continuous loading of samples (64 positions) THROUGHPUT Up to 140 tests/hour READING SYSTEM Direct photometry MINIMUM REACTION VOLUME 300 μl Photometer multi - wavelenght optics, double beam Wavelength 12 narrow band interferential filters (9 on board) Source halogen lamp 6V/10W OPTICS SYSTEM Optical Path 6 mm Linear range 0.001 - 2.500 Abs Resolution 0.0001 Abs One mechanic arm provides all sampling operation with : ed. - Capacitive liquid level sensing eserv - Reagent pre-warming at 37°C SAMPLING SYSTEM - Automatic probe washing - Sample Volume range : 3.0 - 300 μl (1μl incr.) - Reagent Volume : 3.0 - 300 μl (1μl incr.) - Sample pre-dilution DILUTOR Automatic dilution in pre and post-dilution Circular 120 semi-disposable cuvettes tray: REACTION PLATE - Automatic cuvette washing - Continuous monitoring of cuvette quality - Incubation temperature: 37°C y be changed without prior notice. All rights r DIMENSIONS 76 x 56 x 59 cm (Height x Depth x Width) WEIGHT 43 Kg es. Specifications ma OPTIONAL ACCESSORIES - Handheld barcode reader - Nitrate module actual pictur Selection Aqua Selection Oeno (Ready-to-use reagents for (Ready-to-use reagents for Water analysis) Wine analysis) Alkalinity (OM) Acetic acid Copper oup. Non contr Alkalinity (BPB) Citric acid Free SO2 Ammonia Gluconic acid Fructose+glucose Chromium VI Lactic acid Glucose READY-TO-USE REAGENTS Chlorides Malic acid Glycerol S ALLIANCE Gr Fluoride Tartric acid Iron Hardness Alpha Amino Nitrogen Potassium 18 AM Nitrate Ammonia Polyphenols Nitrite Anthocyanin Sucrose Phosphates Arginine Total Acidity Silicate Calcium Total SO2 Sulfates Catechin Urea © September 20 AMS France 10 avenue Charles de Gaulle 95740 Frepillon FRANCE NEW ORDER ONLINE Tel. : (+33) 134 18 71 10 reagents and consumables. Fax : (+33) 139 60 72 39 www.amsalliance.com http://webshop.amsalliance.com