KNAUER High-Pressure Dosing Pumps Science Together 2019/20 KNAUER High-Pressure Dosing Pumps Selection Guide Pumps, flow meters and accessories for a wide range of dosing applications Made in Germany Sales If you want to learn more about our products and services or get a quote, the experts from our Sales team are happy to assist you with your request. Phone: +49 30 809727-0 (workdays 9-17h CET) Fax : +49 30 8015010 Email: sales@knauer.net Service & Support Do you have questions about the installation or the operation of your instrument or software? Our friendly and competent Service & Support staff will be glad to answer your questions. Phone: +49 30 809727-111 (workdays 9-17h CET) Fax : +49 30 8015010 Email: support@knauer.net Download the digital brochure via QR code or visit www.knauer.net/dosingpump-psg Made in Germany since 1962 Based in Berlin, KNAUER is a medium-sized, owner- managed company that has been serving the sciences since 1962. We develop and manufacture scientific instruments of superior quality for liquid chromatography. The range includes systems and components for analytical HPLC / UHPLC, preparative HPLC, fast protein liquid chromatography (FPLC), multi-column chromatography / simulated moving bed (SMB), and osmometry. Independent and family owned The founder Dr. Herbert Knauer and his wife Roswitha are still active as advisers in the company to this day. The couple‘s daughter, Alexandra Knauer, has been managing director and owner of the company since 2000. Several awards for outstanding products and innovations as well as entrepreneurial excellence make KNAUER a „leading employer“. Comprehensive service from the manufacturer Our wide-ranging services complement our excellent instruments: The trainings are performed by experts and cover a variety of topics for beginners to experienced users. The high-performance customer support and repair service provide fast and spot on solutions. If you need support for your research project, we help you to develop applications, transfer and optimize methods or develop software. Dosing pump configurator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 High-pressure dosing pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Flow-pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Chemical compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Accurate dosing for demanding applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Temperature control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dosing pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 BlueShadow Pump 40P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 BlueShadow Pump 80P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 AZURA® Pump P 2.1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 AZURA® Pump P 4.1S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Mass flow controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Pump accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Consumables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 KNAUER brochures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Chemical compatibility of wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . .28 Pump head compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Conversion tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Terms and conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 CONNECTIONS: PRESSURE: Inlet port Outlet port Inlet pressure ambient 1/16“ elevated: ............ bar 1/8“ Max. outlet pressure .................... bar 1/4“ Other: ........... ........... PUMP: Max. flow rate ........................ ml/min Quantity of pumps .................... LIQUIDS: Liquids ........................................ (please specify concentration) ........................................ ........................................ Temperature ......................... °C pump Viscosity .................... mPa∙s OTHER REQUIREMENTS: Chemical compatibility specifications ....................................................................................................... Extended material documentation Yes No GMP compliant Yes No Pressure sensor Yes No Mass flow controller Yes No Communication protocol Yes No Heater/cooler Yes No Operation time Continuous (24h/7d) Intermittent (8h/5d) Service & Installation Inhouse External Control Manual (standalone) Analog Ethernet Mobile Control RS-232 ADDITIONAL REQUIREMENTS: Request a quote online: www.knauer.net/en/Systems- .................................................................................... Solutions/Pumps/Request-a-quote .................................................................................... .................................................................................... KNAUER Dosing Pump Selection Guide | 1 Precise dosing in the laboratory and in production KNAUER dosing pumps are highly accurate two-piston pumps for applications in the chemical and pharmaceutical industries as well as in research and method development. They pump and dose aqueous and organic liquids, aggressive media or liquid gases. The metering pumps impress with their high chemical resistance, excellent flow rate precision and low pulsation of the pumped medium in a wide range of applications: � Flow rates from 0.01 ml/min to 1,000 ml/min � High pressure range up to 650 bar � Wide temperature range from -10 °C to 120 °C � Viscous liquids up to 1,000 mPa-s KNAUER dosing pumps are intregrated easily in your dosing application due to an independent control via display or touchscreen. To choose the right pump type, the following aspects must be considered: F L O W A N D C H E M I C A L C O N N E C T I V I T Y M A S S F L O W P R E S S U R E R A N G E CO M PAT I B I LIT Y C O N T R O L Application areas � Chemical engineering � Pharma � Process engineering � Research & Development Application examples � Flow chemistry � Polymer production � Microfluidics � Dosing of aggressive or radioactive substances 2 | KNAUER Dosing Pump Selection Guide Easily choose the right dosing pump for your application When choosing a dosing system, flow rate and pressure range are key parameters. KNAUER dosing pumps are designed for HPLC applications and thus feature excellent pressure stability, low pulsation and precise delivery at flow rates from 0.01 - 1000 ml/min. AZURA® Pump P 2.1S / P 4.1S For flow rates of up to 50 ml/min e (bar) Pressur Flow rate (ml/min) 10 ml pump head stainless steel recommended continuous 10 ml pump head ceramic 50 ml pump head stainless steel 50 ml pump head ceramic BlueShadow Pump 40P Compact solution for flow rates of up to 50 ml/min e (bar) Pressur Flow rate (ml/min) 10 ml pump head stainless steel recommended continuous 10 ml pump head ceramic 50 ml pump head stainless steel 50 ml pump head ceramic KNAUER Dosing Pump Selection Guide | 3 BlueShadow Pump 80P For flow rates of up to 1000 ml/min e (bar) Pressur Flow rate (ml/min) 100 ml pump head recommended continuous 250 ml pump head 500 ml pump head 1000 ml pump head In order to optimally adapt the dosing solution to your tasks, the wetted materials must be perfectly matched to the application. KNAUER dosing pumps are resistant to a wide range of chemicals. Depending on the pumped medium, the wetted materials can be stainless steel, titanium, Hastelloy C or ceramic. A choice of check valves, seals and piston rods for various types of eluents is available. Thanks to the replaceable pump head, which is automatically detected by all BlueShadow pumps, the metering pumps can be adapted to new tasks. The documentation of operating hours is simplified by the automatic recording of the running time and maintenance cycles can be easily planned. 4 | KNAUER Dosing Pump Selection Guide KNAUER dosing pumps offer a wide range of control options. Configuration and adjustment of the flow rate can be made via keyboard and display or touch screen (depending on the device). Smaller test arrangements for setting a constant flow rate can be realized quickly and easily. In addition, all KNAUER metering pumps can be remote controlled via various interfaces. A flow rate can be set via the local network (LAN) using suitable software. Control via a serial RS-232 interface is also possible. KNAUER dosing pumps also offer a wide range of possibilities for control via an analog signal. KNAUER pumps can be controlled with a wide range of software solutions. The hand-held Mobile Control LAN allows device monitoring with a touch-optimized user interface. Drivers for chromatography data RS-232 systems (ClarityChrom®, PurityChrom®, OpenLab CDS EZChrom Edition and Chromeleontm) are analog available. If you want to integrate KNAUER devices into a specific process control system, we can provide the communication protocol of our pumps free of charge. Gain flexibility, improve precision Demanding metering applications for liquids with different viscosities or precise batch dosing tasks need a particularly exact control of the flow rate. Since KNAUER pumps support a wide variety of communication interfaces, the dosing pumps can be combined with mass flow controllers to meet these challenging demands. Constant fluid temperature is a key factor for many applications. Pump head heating facilitates dosing of viscous liquids, while pump head cooling prevents evaporation of liquid gases. To avoid temperature gradients, the pump heads of all KNAUER pumps can be equipped with temperature control. With the BlueShadow Pump 40P high temperature version, fluid temperatures of up to 120°C can be achieved. Al other pumps can be heated up to 60°C. Choose between an electrical heating solution and a heat exchanger in combination with a thermostat. KNAUER Dosing Pump Selection Guide | 5 BlueShadow Pump 40P The BlueShadow Pump 40P was designed to provide exceptionally precise and reliable solvent delivery for a wide range of dosing applications. Exchangeable pump heads with maximum flow rates of 10 and 50 ml/min cover a wide range of high-pressure dosing tasks. Practically pulse-free flow is achieved by our en-hanced smart drive control which actively prevents pressure ripple instead of just dampening it. The improved design also ensures a low dead volume. Pump heads for high-temperature applications enable solvent delivery at up to 120°C. Minimize temperature gradients by adding a pump head heater and insulation sleeve. Specifications Solvent delivery Pump type Analytical HPLC pump Delivery system Dual piston pump with one working piston, one auxillary Pulsation compensation Active Pulsation Compensation Piston seal washing Active Wash Flow rate accuracy ± 1% (measured at 5 - 80% of flow range using ethanol) Flow rate precision < 0.1% RSD Pulsation < 2 % amplitude (typically < 1.3 %) or < 0.3 MPa (3 bar), whatever is greater, at 1 mL/min ethanol, at all pressures> 1 MPa (10 bar, 147 psi). System protection Pmin und Pmax adjustable Liquid temperature range 4−120 °C (39.2−248 °F) Leak management No Pump head inlet (standard) UNF 1/4-28 Thread Pump head outlet (standard) UNF 10-32 Thread Communication Display Touchscreen Inputs LAN, RS-232, Pin header connectors (Analog IN, Start In, Error IN) Analog inputs Flow rate, 0 - 10 V via pin header connectors Analog control input Flow Rate Level/event outputs 8 event outputs (TTL, OC, Relais) and 24 V Control Touchscreen, LAN, RS-232, Analog and event control Programming 10 programs, 9 program links + wake up program, supports gradients Technical parameters Leak sensor No Special features Pump Head is detected automatically using radio frequency indentificaion (RFID) GLP RFID pump head recognition, detailed report Conformity IP20 ingress protection Display Touchscreen Ambient conditions 4 - 40 °C (50-104 °F), Air humidity below 90%, non-condensing General Power supply 100 - 240 V; 50 - 60 Hz; Maximum power consumption 320 Watt Dimensions 361 mm x 208.2 mm x 523 mm (W × H × D) Weight 6,1 kg Optional accessories High temperature pump head, pump head heating and cooling device A variety of software control options is available: For accessories KNAUER offers various options for drivers. see page 16. For more information, please visit www.knauer.net/softwarecontrol 6 | KNAUER Dosing Pump Selection Guide Dosing pumps Specifications Pump head 10 ml Flow rate range 0.001 - 10 ml/min Maximum delivery pressure 9430 psi / 650 bar / 65 MPa up to 5 ml/min; 5800 psi / 400 bar / 40 MPa up to 10 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM, PEEK, sappire, aluminium oxide, ruby, zirconium oxide, titanium and pump head material Maximum viscosity 100 mPa s Flow rate increment 0.001 ml/min Best working conditions 0.1 - 8.0 ml/min Continuous working conditions 0.1 - 4.0 ml/min Pumphead material Stainless steel / ceramic Ordering details: APC30EA BlueShadow Pump 40P with 10 ml pump head, stainless steel APC30EB BlueShadow Pump 40P with 10 ml pump head, ceramic APC30EE BlueShadow Pump 40P with 10 ml pump head, stainless steel (for high temperature applications up to 120°C) APC30EI BlueShadow Pump 40P with 10 ml pump head, stainless steel, with backpiston flushing (for high temperature applications up to 120°C) Specifications Pump head 50 ml Flow rate range 0.001 - 50 ml/min Maximum delivery pressure 4350 psi / 300 bar / 30 MPa up to 10 ml/min; 2900 psi / 200 bar / 20 MPa up to 50 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM, PEEK, sappire, aluminium oxide, ruby, zirconium oxide, titanium and pump head material Maximum viscosity 100 mPa s Flow rate increment 0.001 ml/min Best working conditions 0.1 - 40 ml/min Continuous working conditions 0.1 - 20 ml/min Pumphead material Stainless steel / ceramic Ordering details: APC30FA BlueShadow Pump 40P with 50 ml pump head, stainless steel APC30FB BlueShadow Pump 40P with 50 ml pump head, ceramic APC30FE BlueShadow Pump 40P with 50 ml pump head, stainless steel (for high temperature applications up to 120°C) APC30FH BlueShadow Pump 40P with 50 ml pump head, stainless steel, with backpiston flushing (for high temperature applications up to 120°C) KNAUER Dosing Pump Selection Guide | 7 BlueShadow Pump 80P The BlueShadow Pump 80P delivers stable and precise solvent flow for your dosing application. By adding one or more additional pumps, binary, ternary or even quaternary high-pressure mixing gradient systems can be easily configured. The pump can also be equipped with a binary or ternary gradient valve block to configure cost-effective low-pressure gradient mixing systems. Exchangeable pump heads for flow rates up to 1 000 ml/min and pressures up to 40 MPa make it possible to easily adapt the pump to changing performance requirements and allow simple maintenance. Available in stainless steel or biocompatible titanium versions, the pump heads enable a wide range of applications. The integrated automatic recognition of the pump head with RFID technology allows fast adaption of the pump. Change from low-flow organic solvent delivery to high-flow biocompatible buffer metering with minium downtime. Specifications Solvent delivery Pump type Preparative HPLC pump Delivery system Dual Piston Pump with two working pistons Pulsation compensation Active Pulsation Compensation Piston seal washing Active Wash Flow rate accuracy ± 2 %, measured at 5 - 50% of the flow range using ethanol/water 10:90 Flow rate precision < 0.1% RSD, measured at 5 - 50% of the flow range using ethanol/water 10:90 System protection Pmin und Pmax adjustable Gradient range 0 - 100 % (with optional LPG valve block) Gradient formation LPG (with optional LPG valve block) or HPG Liquid temperature range 4−60 °C (39.2−140 °F) Pump head inlet (standard) M8 x 1 (flat bottom) Pump head outlet (standard) M8 x 1 (coned) Communication Display Touchscreen Inputs LAN, RS-232, Pin header connectors (Analog IN, Start In, Error IN) Analog inputs Flow rate, 0 - 10 V via pin header connectors Analog control input Flow Rate Level/event outputs 8 event outputs (TTL, OC, Relais) and 24 V Control Touchscreen, LAN, RS-232, Analog and event control Programming 10 programs, 9 program links + wake up program, supports gradients Technical parameters Special features Pump Head is detected automatically using radio frequency indentificaion (RFID) Conformity IP20 ingress protection Ambient conditions 4 - 40 °C (50-104 °F), Air humidity below 90%, non-condensing General Power supply 100 - 240 V; 50 - 60 Hz; Maximum power consumption 320 Watt Dimensions 397 mm x 242 mm x 201 mm (W × H × D) Weight 10.1 kg Optional accessories Ternary low pressure gradient (LPG) valve block (10 - 220 ml/min), binary LPG valve block (10 - 800 ml/min), pump head heating and cooling device, mixer A variety of software control options is available: KNAUER offers various options for drivers. For accessories For more information, please visit see page 16. www.knauer.net/softwarecontrol 8 | KNAUER Dosing Pump Selection Guide Specifications Pump head 100 ml Flow rate range 0.01 - 100 ml/min Maximum delivery pressure 5800 psi / 400 bar / 40 MPa Wetted materials Aluminium oxide (Al2O3), FKM, graphite fiber reinforced PTFE, PEEK, sapphire, stainless steel, titanium Maximum viscosity 1000 mPa s Flow rate increment 0.01 ml/min Best working conditions 1 - 80 ml/min Continuous working conditions 1 - 40 ml/min Pumphead material Stainless steel / titanium Ordering details: APD20KA BlueShadow Pump 80P with 100 ml pump head (stainless steel) APD20KB BlueShadow Pump 80P with 100 ml pump head (titanium) Specifications Pump head 250 ml Flow rate range 0.01 - 250 ml/min Maximum delivery pressure 3260 psi / 225 bar / 22.5 MPa up to 100 ml/min, 2900 psi / 200 bar / 20 MPa up to 250 ml/min Wetted materials Aluminium oxide (Al2O3), FKM, graphite fiber reinforced PTFE, PEEK, sapphire, stainless steel, titanium Maximum viscosity 1000 mPa s Flow rate increment 0.1 ml/min Best working conditions 2.5 - 200 ml/min Continuous working conditions 2.5 - 100 ml/min Pumphead material Stainless steel / titanium Ordering details: APD20LA BlueShadow Pump 80P with 250 ml pump head (stainless steel) APD20LC BlueShadow Pump 80P with 250 ml pump head (titanium) KNAUER Dosing Pump Selection Guide | 9 Specifications Pump head 500 ml Flow rate range 0.01 - 500 ml/min Maximum delivery pressure 1450 psi / 100 bar / 10 MPa Wetted materials Aluminium oxide (Al2O3), FKM, graphite fiber reinforced PTFE, PEEK, sapphire, stainless steel, titanium Maximum viscosity 1000 mPa s Flow rate increment 0.1 ml/min Best working conditions 5 - 400 ml/min Continuous working conditions 5 - 200 ml/min Pumphead material Stainless steel / titanium Ordering details: APD20MA BlueShadow Pump 80P with 500 ml pump head (stainless steel) APD20MC BlueShadow Pump 80P with 500 ml pump head (titanium) Specifications Pump head 1000 ml Flow rate range 1 - 1000 ml/min Maximum delivery pressure 1087 psi / 75 bar / 7.5 MPa to 350 ml/min, 725 psi / 50 bar / 5 MPa up to 1000 ml/min Wetted materials Aluminium oxide (Al2O3), FKM, graphite fiber reinforced PTFE, PEEK, sapphire, stainless steel, titanium Maximum viscosity 1000 mPa s Flow rate increment 0.1 ml/min Best working conditions 10 - 800 ml/min Continuous working conditions 10 - 400 ml/min Pumphead material Stainless steel / titanium Ordering details: APD20NA BlueShadow Pump 80P with 1000 ml pump head (stainless steel) APD20NB BlueShadow Pump 80P with 1000 ml pump head (titanium) 10 | KNAUER Dosing Pump Selection Guide AZURA® Pump P 2.1S AZURA® Pump P 2.1S was developed for eluent delivery up to 400 bar and for flow rates up to 50 ml/min in HPLC and other applications where a compact easy-to-integrate pump is required. This pump is the perfect choice for dosing applications as the exchangeable pump heads are compatible to a wide range of chemicals. Specifications Solvent delivery Pump type Ultra-compact high pressure pump Delivery system Dual piston pump with one working piston, one auxillary Pulsation compensation No Piston seal washing Passive Wash Flow rate accuracy ± 5%, measured at 5 - 50% of flow range using ethanol/water 10:90. ±2% at calibration point (one point calibration), measured at 5 - 50% of flow range Flow rate precision ≤ 0.5% RSD, measured at 1/5 ml/min using ethanol/water 10:90 System protection Imin und Imax are programmable (I ~ pressure) Liquid temperature range 4−60 °C (39.2−140 °F) Pump head inlet (standard) UNF 1/4-28 Thread Pump head outlet (standard) UNF 10-32 Thread Communication Display Yes Inputs LAN, Pin header connectors (Analog IN, Start In, Error IN), RS-232 Analog inputs 0 - 10 V Analog control input Flow Rate Control LAN, RS-232, analog, standalone Technical parameters Display Yes Ambient conditions 10-40 °C (50-104 °F) Air humidity below 90%, non-condensing General Power supply 100 - 240 V; 50 - 60 Hz; Maximum power consumption 100 Watt Dimensions 121 x 129 x 220 mm (W × H × D) Weight 2.3 kg A variety of software control options is available: KNAUER offers various options for drivers. For accessories For more information, please visit see page 16. www.knauer.net/softwarecontrol KNAUER Dosing Pump Selection Guide | 11 Specifications Pump head 10 ml Flow rate range 0.001 - 10 ml/min Maximum delivery pressure 5800 psi / 400 bar / 40 MPa up to 10 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM (FFKM for APG90EC), PEEK (PCTFE for APG90EC), sapphire, ruby, zirconium oxide and pump head material Maximum viscosity 100 mPa s (at reduced max. flow) Flow rate increment 0.001 ml/min Best working conditions 0.1 - 8.0 ml/min Continuous working conditions 0.1 - 4.0 ml/min Pumphead material Stainless steel / ceramic / Hastelloy® C Ordering details: APG90EA AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min stainless steel pump head APG90EB AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min ceramic pump head APG90EC AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min Hastelloy® C pump head APG90EG AZURA® Pump P 2.1S compact HPLC pump with 10 ml/min stainless steel pump head, recommended for aqueous solutions Specifications Pump head 50 ml Flow rate range 0.01 - 50 ml/min Maximum delivery pressure 2180 psi / 150 bar / 15 MPa up to 50 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM (FFKM for APG90FC), PEEK (PCTFE for APG90FC), sapphire, ruby, zirconium oxide and pump head material Maximum viscosity 100 mPa s (at reduced max. flow) Flow rate increment 0.01 ml/min Best working conditions 0.5 - 40.0 ml/min Continuous working conditions 0.5 - 20 ml/min Pumphead material Stainless steel / ceramic / Hastelloy® C Ordering details: APG90FA AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min stainless steel pump head APG90FB AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min ceramic pump head APG90FC AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min Hastelloy® C pump head APG90FG AZURA® Pump P 2.1S compact HPLC pump with 50 ml/min stainless steel pump head, recommended for aqueous solutions 12 | KNAUER Dosing Pump Selection Guide AZURA® Pump P 4.1S The AZURA® Pump P 4.1S was developed for eluent delivery up to 400 bar and for flow rates up to 50 ml/ min in HPLC and other applications where a compact easy-to-integrate pump is required. Apart from serving as a compact isocratic pump for small HPLC systems, it can also be used as a sample pump for preparative chromatography. This pump is the perfect choice for dosing applications as the exchangeable pump heads are compatible to a wide range of chemicals. Specifications Solvent delivery Pump type Ultra-compact high pressure pump Delivery system Dual piston pump with one working piston, one auxillary Piston seal washing Passive Wash Flow rate accuracy ± 1%, measured at 5 - 50% of flow range using ethanol/water 10:90 Flow rate precision ≤ 0.5% RSD, measured at 1/5 ml/min using ethanol/water 10:90 System protection Pmin und Pmax are programmable Liquid temperature range 4−60 °C (39.2−140 °F) Pump head inlet (standard) UNF 1/4-28 Thread Pump head outlet (standard) UNF 10-32 Thread Communication Display Yes Inputs LAN, Pin header connectors (Analog IN, Start In, Error IN), RS-232 Analog inputs 0 - 10 V Analog control input Flow Rate Control LAN, RS-232, analog, standalone Technical parameters Display Yes Ambient conditions 10-40 °C (50-104 °F) Air humidity below 90%, non-condensing General Power supply 100 - 240 V; 50 - 60 Hz; Maximum power consumption 100 Watt Dimensions 121 x 129 x 220 mm (W × H × D) Weight 2.4 kg A variety of software control options is available: KNAUER offers various options for drivers. For accessories For more information, please visit see page 16. www.knauer.net/softwarecontrol KNAUER Dosing Pump Selection Guide | 13 Mass flow controllers Specifications Pump head 10 ml Flow rate range 0.001 - 10 ml/min Maximum delivery pressure 5800 psi / 400 bar / 40 MPa up to 10 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM (FFKM for APG20EC), PEEK (PCTFE for APG20EC), sapphire, ruby, zirconium oxide, titanium and pump head material Maximum viscosity 100 mPa s (at reduced max. flow) Flow rate increment 0.001 ml/min Best working conditions 0.1 - 8.0 ml/min Continuous working conditions 0.1 - 4.0 ml/min Pumphead material Stainless steel / ceramic / Hastelloy® C Ordering details: APG20EA AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min stainless steel pump head, stainless steel connections APG20EB AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min ceramic pump head, PEEK connections APG20EC AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min Hastelloy® C pump head, Titanium pressure sensor, Hastelloy® C connections APG20EF AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min ceramic pump head, Ti connections. APG20EG AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min stainless steel pump head, stainless steel connections, recommended for aqueous solutions APG20EH AZURA® Pump P 4.1S compact HPLC pump with 10 ml/min ceramic pump head, Titanium connections, recommended for aqueous solutions Specifications Pump head 50 ml Flow rate range 0.01 - 50 ml/min Maximum delivery pressure 2180 psi / 150 bar / 15 MPa up to 50 ml/min Wetted materials Graphite fiber reinforced PTFE, FKM (FFKM for APG20FC), PEEK (PCTFE for APG20FC), sapphire, ruby, zirconium oxide, titanium and pump head material Maximum viscosity 100 mPa s (at reduced max. flow) Flow rate increment 0.01 ml/min Best working conditions 0.5 - 40.0 ml/min Continuous working conditions 0.5 - 20 ml/min Pumphead material Stainless steel / ceramic / Hastelloy® C Ordering details: APG20FA AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min stainless steel pump head, stainless steel connections APG20FB AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min ceramic pump head, PEEK connections APG20FC AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min Hastelloy® C pump head, Hastelloy® C connections APG20FG AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min stainless steel pump head, stainless steel connections, recommended for aqueous solutions APG20FI AZURA® Pump P 4.1S compact HPLC pump with 50 ml/min ceramic pump head, PEEK connections, recommended for aqueous solutions 14 | KNAUER Dosing Pump Selection Guide Mini CORI-Flow are precise and compact mass flowmeters and controllers, based on the Coriolis measuring principle. Coriolis flowmeters are unmatched in accuracy. When applied for liquids, the mass flow accuracy is better than ±0,2% relative deviance. Instruments of the mini CORI-Flow series contain a uniquely shaped, single loop sensor tube, forming part of an oscillating system. When a fluid flows through the tube, Coriolis forces cause a variable phase shift, which is detected by sensors and fed into the integrally mounted pc-board. The resulting output signal is strictly proportional to the real mass flow rate. The mini CORI-Flow features density and temperature of the fluid as secondary outputs. Advantages of mass flow controlled systems: • Precise metering independent of liquid density and temperature • No calibration required when changing liquids • Volume logging incl. signal • Batch dosing Specifications Flowmeter Flow rate range 3 different ranges available. See ordering details. Flow rate accuracy ± 0.2 % of rate * Wetted materials stainless steel AISI 316 or equivalent optional Hastelloy-C22 Communication Outputs 0 – 5 (10) Vdc or 0 (4) – 20 mA Control standard: RS–232 (8-pinDIN male connection) Profibus-DP® bus:(5-pin M12 female; power 8-pin DIN male)DeviceNet™ Modebus-RTU; LonWorks Flow bus (5–pin M12 male) General Power supply +15–24VDC ±10 % max. ripple recommended: 50mV tt Weight Meter: 1.2 kgController: 1.7 kg Other Note * optimal accuracy will be reach after approx. 30 minutes after instrument power up Ordering details: A5390 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, Flow: 1 - 50 ml/min, stainless steel 316 A5391 Mini CORI-Flow (M14) Mass flow controller incl. mounting block, Flow: 2 - 833 ml/min, stainless steel 316 A5393 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, Flow: 1 - 50 ml/min, stainless steel 316, Profibus A5394 Mini CORI-Flow (M12) Mass flow controller incl. mounting block, Flow: 0,03 – 1,66 ml/min, stainless steel 316 A5395 Mini CORI-Flow (M13) Mass flow controller incl. mounting block, Flow: 1 - 50 ml/min, Hastelloy-C22 A5396 HI-TEC Bright display for Mini CORI-Flow mass flow controller (display, setpoint and counter) A variety of software control options is available: KNAUER offers various options for drivers. For accessories For more information, please visit see page 16. www.knauer.net/softwarecontrol KNAUER Dosing Pump Selection Guide | 15 Pump accessories Solvent filters & inlet tubing Mobile Phase Filter, stainless steel, 2 µm, 1/8” pipe OD, suitable for all analytical A3373 HPLC systems Mobile Phase Filter, stainless steel, 20 μm, for 1/8” OD, compatible with the A3374 AZURA® Tubing Kit (A9650), suitable for all analytical and semi preparative HPLC systems, max. flow rate 100 ml/min Mobile Phase Filter, stainless steel, 10 μm, for 1/8” OD,compatible with the A3375 A3374 AZURA® Tubing Kit (A9650), suitable for all analytical HPLC systems, max. flow rate A3364 A3375 10 ml/min Mobile Phase Filter, Biocompatible PE, 20 µm, 1/8“ pipe OD, suitable for all FPLC A3364 systems, max. flow rate 500 ml/min AZURA® Tubing kit with cap and solvent filter (A3375, stainless steel, 10 µm), A9650 suitable for all analytical HPLC systems AZURA® Tubing Kit bio with cap and insert, solvent filter inlet and fittings, 1set A96507 A9650 Solvent Filter 1/4”-PTFE Tubing up to 250 ml/min A58207 Filter Cartridge for pump P 6.1L, Titanium frit, 2 µm pore size. 50 ml/min maximum A9661 flow, High capacity filter, 60 µl volume, 3 pcs. Filter Cartridge for pump P 6.1L, Stainless steel frit, 2 µm pore size. 10 ml/min A96601 maximum flow, Volume optimized filter, 20 µl volume, 3 pcs. A96507 PTFE tubing, 1/4” OD, 4,75 mm ID, 300 cm length A08732 PTFE tubing 1/8’’ OD, 2 mm ID, 300 cm length A0873 PTFE tubing, 3/8’’ OD , 8 mm ID, variable length A01521 FEP tubing, 1/8” OD, 2.1 mm ID, 300 cm length A9869 FEP tubing, 1/16” OD, 0.81 mm ID, 300 cm length A9869-1 Mixers Mixing is an important task when two or more pumps deliver fluids into the same feed line. Choose between static mixers for small volumes and dynamic mixers for high flow rates. Dynamic mixers Dynamic mixing chamber (250 V), stainless steel, analytical, 1/16“, up to 420 bar, A0285 1740 µl mixing volume Dynamic mixing chamber (115 V), stainless steel, analytical, 1/16“, up to 420 bar, A02851 1740 µl mixing volume Dynamic mixing chamber (250 V), stainless steel, preparative, 1/8“, up to 250 bar, A0581 5.9 ml mixing volume Dynamic mixing chamber (115 V), stainless steel, preparative, 1/8“, up to 250 bar, A05811 5.9 ml mixing volume Dynamic mixing chamber (250 V), titanium, analytical, 1/16“, up to 420 bar, 1740 µl A0275 mixing volume Dynamic mixing chamber (115 V), titanium, analytical, 1/16“, up to 420 bar, 1740 µl A02751 mixing volume Dynamic mixing chamber (250 V), titanium, preparative, 1/8“, up to 250 bar, 5.9 ml A70581 mixing volume Dynamic mixing chamber (115 V), titanium, preparative, 1/8“, up to 250 bar, 5.9 ml A705811 mixing volume Mixing chamber extension unit for A70581/ A705811, 1 intermediate section, A2515 titanium, 4.8 ml, 3 screws 6 x 60 mm 16 | KNAUER Dosing Pump Selection Guide Static mixers AZURA® HPLC mixer up to 100 MPa, 50 µl mixing volume, stainless steel AZZ00MB AZURA® HPLC mixer up to 100 MPa, 100 µl mixing volume, stainless steel AZZ00MC AZURA® HPLC mixer up to 100 MPa, 200 µl mixing volume, stainless steel AZZ00MD AZZ00MB AZURA® HPLC mixer up to 40 MPa, 250 µl mixing volume, PEEK (biocompatible) AZZ10ME HyperShear Static Mixer, (1.5mL), high flow series, stainless steel and PEEK A5830 Mounting bracket AZURA® L for Hypershear mixing chambers A9853-8 AZZ10ME A5830 Pump head inlet fittings Pump head inlet for AZURA® Pump P 2.1L, BlueShadow 80P, 1/4” (NPT), stainless A9861 steel, max. flow 250 ml/min Pump head inlet for AZURA® Pump P 2.1L, Set, 1/2”-20 UNF, PEEK with CTFE A9868 (Kel-F) adapter, including tubing 1/4“ PTFE Inlet bushing for prep pump heads, adapter to 3/8” tube stub A98611 Inlet bushing for binary LPG prep pump heads, LPG inlet to 3/8” tube stub A98612 A9861 Inlet bushing for LPG prep pump heads, LPG ternary inlet to 3/8” tube stub A98613 Male connector to connect a 1/4’’ OD capillary to a 1/4’’ male NPT adapter A58267 (material: stainless steel) for A9861 Male connector to connect a 4 mm OD capillary to a 1/4’’ male NPT adapter A58268 (material: stainless steel) for A9861 Male connector to connect a 1/8’’ OD capillary to a 1/4’’ male NPT adapter A58269 A9868 (material: stainless steel) for A9861 Inlet-bushing kit for P 2.1S, P 4.1S, P6.1L, 40P and S1050 pumps for pump heads A58202 10 ml (1/8” capillaries) Inlet-bushing kit for P 2.1S, P 4.1S, P6.1L, 40P and S1050 pumps for pump heads A58203 10 ml (1/16” capillaries) Inlet-bushing kit for P 2.1S, P 4.1S, P6.1L, 40P and S1050 pumps for pump heads A58204 50 ml (1/8” capillaries) A58267 A98611 A58268 A98612 Inlet-bushing kit for P 2.1S, P 4.1S, P6.1L, 40P and S1050 pumps for pump heads A58205 A58269 A98613 50 ml (1/16” capillaries) Pump head outlet fittings Outlet-bushing kit 1/8” tube stub for S1800, 80P and P 2.1L pumps A5822 Adapter to connect a capillary with 1/16” OD (thread: 10-32 UNF) to AZURA® A7200 Pump P2.1L or BlueShadow Pump 80P outlet (1/8”, M8x1 thread), material: stainless steel A5822 Check valves Check valve unit for 10 ml (AZURA® Pump P 4.1S/ P 2.1S, BlueShadow 40P) A06841 Check valve unit for 50 ml (AZURA® Pump P 4.1S/ P 2.1S, BlueShadow 40P) A06842 Check valve unit (KEL-F) for 10 ml pump head A068412 (AZURA® Pump P 2.1S/P4.1S, BlueShadow 40P) Check valve unit (spring-loaded) for 10 ml and 50 ml pump head A068411 (AZURA® Pump P 4.1S/ P 2.1S, BlueShadow 40P) Check valve unit for 100 ml and 250 ml pump head A1122 (AZURA® Pump P 2.1L, BlueShadow 80P) Check valve unit for 500 ml and 1000 ml pump head A1080 (AZURA® Pump P 2.1L, BlueShadow 80P) KNAUER Dosing Pump Selection Guide | 17 Replacement pump heads for AZURA® Pump P 2.1S/P 4.1S Pump head 10 ml, stainless steel AHB40 Pump head 10 ml, ceramic AHB32 Pump head 10 ml, ceramic with Ti-bushings AHB32DA Pump head 10 ml, Hastelloy-C, for corrosive chemicals AHB43 Pump head 50 ml, stainless steel AHC20 Pump head 50 ml, ceramic AHC22 Pump head 50 ml, Hastelloy-C, for corrosive chemicals AHC23 Pump head, 10 ml, stainless steel, for aqueous solutions AHB40FA Pump head 10 ml, ceramic, titanium bushings, for aqueous solutions AHB32GA AHB32 Pump head 50 ml, stainless steel, for aqueous solutions AHC20FA Pump head 50 ml, ceramic , for aqueous solutions AHC22FA Replacement pump head for BlueShadow Pump 40P Pump head 10 ml, stainless steel AHB40 Pump head 10 ml, ceramic AHB32 Pump head 50 ml, stainless steel AHC20 Pump head 50 ml, ceramic AHC22 Pump head 10 ml, stainless steel, for high temperature dosing applications AHB40CA Pump head 50 ml, stainless steel, for high temperature dosing applications AHC20CA Pump head 10 ml, stainless steel, for high-temperature dosing applications AHB40CB Pump head 50 ml, stainless steel, for high temperature dosing applications AHC20CB AHB40 Replacement pump heads for BlueShadow Pump 80P Pump head 100 ml, stainless steel A4029-1 Pump head 100 ml, titanium A4029V1 Pump head 250 ml, stainless steel A4021-1 Pump head 250 ml, titanium A4021V1 Pump head 500 ml, stainless steel A4038-1 Pump head 1000 ml, stainless steel A4022-1 A4029-1 Pump head 1000 ml, titanium A4022V1 LPG modules LPG module for Pump 80P binary up to 800 ml/min (stainless steel) AZZ00AA-1 LPG module for Pump 80P ternary up to 220 ml/min (stainless steel) AZZ00AB-1 AZZ00AB Pulse dampers KNAUER Pulse Damper, high volume, stainless steel AZZ00NB KNAUER Pulse Damper, low volume, stainless steel AZZ00NA 18 | KNAUER Dosing Pump Selection Guide Temperature control Pump head cooling and heating device for 10 and 50 ml/min pump heads A2035-1 Pump head cooling and heating device for 100/250/500/1000 ml/min pump A2034-1 heads Heating element for 10 and 50 ml/min pump heads A57035 Heating solution for 10 and 50 ml/min pump heads, includes heating plate and A57036 insulation sleeve Temperature controller for pump head heater / column heating sleeve A57024 Maintenance kits Maintenance kit for AZURA® Pump P 2.1S/ P 4.1S, AZURA® Pump P 6.1L, A96423 BlueShadow 40P, 10 ml pump head, including 1 set of gaskets, 2 piston rods, 2 sapphire backing rings, 2 O-rings Maintenance kit for AZURA® Pump P 4.1S & P 2.1S, AZURA® Pump P 6.1L, A96424 BlueShadow 40P, 50 ml pump head, including 1 set of gaskets, 2 piston rods, 2 sapphire backing rings, 2 O-rings Maintenance kit 100 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 A96425 sets of gaskets, 2 piston rods, 2 springs Maintenance kit 250 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 A96426 sets of gaskets, 2 piston rods, 2 springs Maintenance kit 500 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including 2 A96427 sets of gaskets, 2 piston rods, 2 springs Maintenance kit 1000 ml for AZURA® Pump P 2.1L and BlueShadow 80P, including A96428 2 sets of gaskets, 2 piston rods, 2 springs Rebuild-Kit for Pump AZURA® Pump P 2.1L and BlueShadow 80P (100ml/250 ml), A58211 Venting screw KEL-F, Check valve unit KEL-F, O-ring Rebuild-Kit for AZURA® Pump P 4.1S & P 2.1S, 10 ml/min pump head., Venting A5821-1 screw KEL-F, Check valve unit KEL-F, O-ring (FFKM) Rebuild-Kit for AZURA® Pump P 4.1S & P 2.1S, 50 ml/min pump head., Venting A5821-2 screw KEL-F, Check valve unit KEL-F, O-ring (FFKM) Maintenance tool kit for 10 ml pump heads A9670 Maintenance tool kit for 50 ml pump heads A9671 Maintenance tool kit for 100 ml pump heads A9672 Maintenance tool kit for 250 ml pump heads A9673 Maintenance tool kit for 500 ml pump heads A9674 Maintenance tool kit 1000 ml pump heads A9675 KNAUER Dosing Pump Selection Guide | 19 Consumables K-Connect system K-Connect Fingertight Fitting, PEEK, long, Set of 2, incl. ferrule, UNF 10/32 Thread A9646 for 1/16 inch K-Connect and PEEK Capillaries K-Connect Fingertight Fitting, PEEK, long, Set of 10, incl. ferrule, UNF 10/32 Thread A9646-1 for 1/16 inch K-Connect and PEEK Capillaries A9646/-1 A9645/-1 K-Connect Fingertight Fitting, Stainless Steel, long, Set of 2, incl. ferrules, UNF A9645 10/32 Thread for 1/16 inch K-Connect Capillaries K-Connect Fingertight Fitting, Stainless Steel, long, Set of 10, incl. ferrules, UNF A9645-1 10/32 Thread for 1/16 inch K-Connect Capillaries K-Connect Standard Fitting, Stainless Steel, Set of 2, incl. ferrule, UNF 10/32 A9647 Thread for 1/16 inch K-Connect Capillaries A9647/-1 K-Connect Standard Fitting, Stainless Steel, Set of 10, incl. ferrule, UNF 10/32 A9647-1 Thread for 1/16 inch K-Connect Capillaries Split-grooved clamping rings 4 Split-grooved clamping rings for capillaries with 1/16” OD A0484 4 Split-grooved clamping rings for capillaries with 1/8” OD A1239 100 Split-grooved clamping rings for capillaries with 1/16” OD A0482 Sealing rings 30 Sealing rings for capillaries with 1/16” OD, PETP A0139 100 Sealing rings for capillaries with 1/16” OD, PETP A0140 10 Sealing rings for capillaries with 1/16” OD, PEEK A1062 10 Sealing rings for capillaries with 1/8” OD, PETP A0232 10 Sealing rings for capillaries with 1/8” OD, PEEK A1063 Biconical sealing rings 10 Biconical sealing rings with 1/16”, PEEK A1070 10 Biconical sealing rings with 1/16”, PETP A1022 10 biconical sealing rings 1/8” PETP A0738 A1070 Bushings for capillaries 1/16” SST 10 Bushings for capillaries with 1/16” OD, stainless steel, wrench caliber 1/4”, UNF A0112 10-32, short 25 Bushings for capillaries with 1/16” OD, stainless steel, wrench caliber 1/4”, UNF A0113 10-32, short 3 Bushings for capillaries with 1/16” OD, stainless steel, wrench caliber 1/4”, UNF A0115 10-32, long 10 Bushings for capillaries with 1/16” OD, stainless steel, wrench caliber 1/4”, UNF A0116 10-32, long 20 | KNAUER Dosing Pump Selection Guide Bushings for capillaries 1/8” SST 10 Bushings for capillaries with 1/8” OD, M8x1, wrench caliber 10, stainless steel A0830 Ferrules for capillaries 30 Ferrules for capillaries with 1/16” OD, stainless steel A0110 100 Ferrules for capillaries with 1/16” OD, stainless steel A0111 10 Ferrules for capillaries with 1/8” OD, stainless steel A0874 10 Ferrules, Hastelloy, for capillaries with 1/16” OD A01101 10 Ferrules, Titanium, for capillaries with 1/16” OD A01102 Bushings for capillaries PEEK & PETP Bushings for 1/16” capillaries, PETP, knurled, UNF 10-32, short, 10 pcs. A0141 Bushings for 1/16” capillaries, PETP, knurled, UNF 10-32, short, 30 pcs. A0142 Bushings for 1/16” capillaries, PETP, UNF 10-32, long, 10 pcs. A0144 Bushings for 1/16” capillaries, PETP, with integrated sealing cone, knurled, UNF A0145 A0584 A0142 10-32, short, 10 pcs. Bushings for 1/16” capillaries, with integrated sealing cone, knurled, PEEK, UNF A0584 10-32, 10 pcs. Bushings for 1/8” capillaries, PETP, with integrated sealing cone, M8x1, knurled, A0733 short,10 pcs. Bushing for 1/16” capillaries, PEEK, short Hex, with integrated sealing cone, 5 pcs. A25011 Bushing for 1/16” capillaries, PEEK, long Hex, with integrated sealing cone, 5 pcs A25021 A0733 A25021 Flat bottom fittings / adapters Bushings flat bottom for 1/8” capillaries, PEEK, Super flangeless, 1/4-28, 10 pcs. A5829 Bushings flat bottom for 1/16” capillaries, PEEK, Super flangeless, 1/4-28, 10 pcs. A58291 Ferrules for 1/16” capillaries and flat bottom bushings, PEEK, with lock ring A58292 (stainless steel), for Super flangeless bushings, 10 pcs. A58291 A5829 Ferrules for 1/8” capillaries and flat bottom bushings, PEEK, with lock ring A58293 (stainless steel), for Super flangeless bushings, 10 pcs. Ferrules for 1/8” capillaries and flat bottom bushings, ETFE, with lock ring (stainless A58294 steel), for Super flangeless bushings, 10 pcs. Adapter PEEK 1/8” flat bottom internal on 1/16” external 10/32 thread A1982 Adapter PEEK 1/8” external thread on 1/16” flat bottom internal thread A05841 Blind fittings Blind fittings, 1/16”, PETP, knurled, UNF 10-32, short, 10 pcs. A0146 Blind fittings, 1/16”, PETP, knurled, UNF 10-32, short, 30 pcs. A0147 Blind fittings, 1/16”, PEEK, knurled, UNF 10-32, short, 10 pcs. A0582 Blind fittings, 1/8”, PETP, knurled, M8x1, short, 10 pcs. A0734 A0734 A0146 A0147 KNAUER Dosing Pump Selection Guide | 21 Couplings, PETP/PEEK Coupling to connect 2 capillaries with 1/16’’ OD (material: PEEK/PETP, thread: A0148 UNF10-32), including 2 bushings and sealing rings, 0.5 mm bore, suitable for classical HPLC, 1 pc. Coupling to connect 2 capillaries with 1/16’’ OD (material: PEEK/PETP, thread: A0149 UNF10-32), including 2 bushings and sealing rings, 0.5 mm bore, suitable for classical HPLC, 5 pcs. Coupling to connect 2 capillaries with 1/16’’ OD (material: PEEK, thread: 10-32 A0233 UNF), including 2 one-piece PEEK fittings, 0.5 mm bore, suitable for classical HPLC Coupling to connect 2 capillaries with 1/16’’ OD (material: PEEK, thread: 10-32 A0233-1 UNF), without fittings, 0.5 mm bore, suitable for classical HPLC Coupling to connect 2 capillaries with 1/16’’ and 1/8”OD (material: PEEK, thread: A1407 10-32 UNF, M8x1), including 2 one piece fittings (1x 1/16”, 1x 1/8“), 1 mm bore Coupling to connect 2 capillaries with 1/8”OD (material: PEEK, thread: M8x1), A14071 including 2 one piece fittings 1/8”, 2 mm bore, suitable for preparative HPLC Couplings, SST/Titanium Coupling to connect 2 capillaries with 1/16’’ OD (material: titanium, thread: 10-32 A0117V1 UNF), including 2 bushings and ferrules, 0.5 mm bore, suitable for classical HPLC Coupling to connect 2 capillaries with 1/16’’ OD (material: stainless steel, thread: A0117 10-32 UNF), including 2 bushings and ferrules, 0.5 mm bore, suitable for classical HPLC Coupling to connect 2 capillaries with 1/16’’ OD (material: stainless steel, thread: A0118 10-32 UNF), including 2 bushings and ferrules, 0.5 mm bore, suitable for classical HPLC, 5 sets Coupling to connect 2 capillaries with 1/16’’ OD (material: stainless steel, thread: A0119 10-32 UNF), including 2 bushings and ferrules, 0.5 mm bore, suitable for classical HPLC, 25 sets Coupling to connect 2 capillaries with 1/8” OD (material: stainless steel, thread: A2512 M8x1), including 2 bushings and ferrules, 2 mm bore, suitable for preparative HPLC Coupling to connect a capillary with 1/16” OD to a capillary with 1/8’’ OD A2513 (material: stainless steel, thread: M8x1, 10-32 UNF), 1 mm bore Coupling Dynaseal to connect a capillary with 1/16” OD to a capillary with 1/8’’ OD A0485 (material: stainless steel, thread: M8x1, 10-32 UNF), including Dynaseal bushings and ferrules (1x 1/16”, 1x 1/8“), 1 mm bore Coupling Dynaseal to connect 2 capillaries with 1/8” OD (material: stainless steel, A0480 thread: M8x1), including 2 Dynaseal bushings and ferrules, 2 mm bore, suitable for preparative HPLC Swagelok® unions & reducing unions, SST Union to connect 2 capillaries with 1/4” OD, material: stainless steel, Swagelok® A58263 Reducer to connect a capillary with 3/8” OD to a capillary with 1/4’’ OD, material: A58264 stainless steel, Swagelok® Reducer to connect a capillary with 8 mm OD to a capillary with 1/4’’ OD, material: A58265 stainless steel, Swagelok® A58270 A58263 Reducer to connect a capillary with 1/8’’ OD to a capillary with 1/4’’ OD, material: A58266 A58271 A58264 stainless steel, Swagelok® A58265 A58266 Reducer to connect a capillary with 1/16’’ OD to a 1/8’’ OD pipe, material: stainless A58270 steel, Swagelok® Reducer to connect a capillary with 1/8’’ OD to a 1/4’’ pipe union, material: A58271 stainless steel, Swagelok® Reducer to connect a capillary with 4 mm OD to a 1/8’’ pipe union, material: A58282 stainless steel, Swagelok® 22 | KNAUER Dosing Pump Selection Guide T-connectors, SST/titanium T-connector to connect 3 capillaries with 1/8’’ OD (material: stainless steel, thread: A2511 M8x1), including 3 bushings and ferrules T-connector to connect 3 capillaries with 1/16’’ OD (material: stainless steel, A0120 thread: 10-32 UNF), including 3 bushings and ferrules A0120 T-connector to connect 3 capillaries with 1/8’’ OD (material: stainless steel, A58260 Swagelok®) T-connector to connect 3 capillaries with 1/4’’ OD (material: stainless steel, A58261 Swagelok®) T-connector to connect 3 capillaries with 1/4’’ OD (material: titanium, Swagelok®) A58262 A58260 A58261 A58262 T-connectors, PEEK T-connector to connect 3 capillaries with 1/16’’ OD (material: PEEK, thread: A150-1 A150-1 10-32 UNF), without bushings T-connector to connect 3 capillaries with 1/8’’ OD (material: PEEK, thread: A2511-1 M8x1),including 2 one piece PEEK fittings 1/8” X-connectors, SST X-connector to connect 4 capillaries with 1/16’’ OD (material: stainless steel, A0121 thread: 10-32 UNF), including 4 bushings and ferrules X-connector to connect 4 capillaries with 1/8’’ OD (material: stainless steel, thread: A1096 M8x1), including 4 bushings and ferrules X-connector to connect 4 tubings with 1/4’’ OD (material: stainless steel, A58272 Swagelok®) for 1000 ml/ min Systems X-connectors, PEEK X-connector to connect 4 capillaries with 1/16’’ OD (material: PEEK, thread: A0151 10-32 UNF), including 4 bushings and sealing rings Pressure release valves Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 50 bar), A5800 1/8”, stainless steel Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 50 bar), A5800V1 1/8”, titanium Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (up to 25 bar), A5801 1/8”, stainless steel Pressure Release Valve for AZURA® pump P 2.1L and Pump 1800 (without spring), A5802 1/4”, stainless steel Back-Pressure Regulator/pressure relief valve for 1/16” OD tubing, stainless steel, A5805 provides a constant back-pressure of 3 bar, contains pressure relief valve tee and fittings for 1/16” Spring for pressure release valve, 25 - 50 bar M1070 Spring for pressure release valve, 3.4-24 bar M1080 M1080 KNAUER Dosing Pump Selection Guide | 23 Backpressure regulators Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, PEEK, Range 1-20 bar A70087 (15-300 psi) Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, PEEK, Range 20-103 A70088 bar (300-1500 psi) Back-Pressure Regulator for 1/16“ OD tubing, 10-32 threads, stainless steel, Range A70084 90-300 bar (1300-4200 psi) Spare membranes for Back-Pressure Regulators A70084, A70087, A70088 A70082 Back-Pressure Regulator/pressure relief valve for 1/8” and 1/16” OD tubing, 134 A5804 A70087 μl volume, PEEK, provides a constant back-pressure of 1.4 bar (20 psi), contains pressure relief valve tee and fittings for 1/8” and 1/16” Back-Pressure Regulator for 1/16” OD tubing, 134 μl volume, PEEK, provides a A5804-1 constant back-pressure of 0.3 bar (5 psi), contains Y assembly and fittings Capillaries 1/16”, SST Stainless steel, 1/16” OD, 0.1 mm ID, 300 cm length, 1 pcs. A0130 Stainless steel, 1/16” OD, 0.25 mm ID, 300 cm length, 1 pcs. A0131 Stainless steel, 1/16’’ OD, 0.5 mm ID, 300 cm length, 1 pcs. A0132 Stainless steel, 1/16” OD, 0.7 mm ID, 300 cm length, 1 pcs. A0133 Stainless steel, 1/16” OD, 1 mm ID, 300 cm length, 1 pcs. A0134 Stainless steel, 1/16” OD, 0.1 mm ID, 10 cm length, 10 pcs. A0123 Stainless steel, 1/16” OD, 0.1 mm ID, 20 cm length, 10 pcs. A0124 Stainless steel, 1/16” OD, 0.1 mm ID, 30 cm length, 10 pcs. A0125 Stainless steel, 1/16’’ OD, 0.25 mm ID, 10 cm length, 10 pcs. A0126 Stainless steel, 1/16’’ OD, 0.25 mm ID, 20 cm length, 10 pcs. A0127 Stainless steel, 1/16” OD, 0.25 mm ID, 30 cm length, 10 pcs. A0128 Capillaries 1/16”, titanium Titanium, 1/16” OD, 0.7 mm ID, 50 cm length, 1 pcs. A0506 Capillaries 1/8”, SST Stainless steel, 1/8”OD, 1.6 mm ID, 150 cm length, 1 pcs. A0639 Stainless steel, 1/8” OD, 2.2 mm ID, 150 cm length, 1 pcs. A0640 24 | KNAUER Dosing Pump Selection Guide Software With the hand-held Mobile Control and Mobile Control Chrom software you have your AZURA devices at your fingertips. Remotely control and monitor your devices and enjoy the touchscreen-optimized user interface. Choose Mobile Control as an easy-to-use and cost-effective device control solution! Mobile Control provides full access to AZURA devices. Change device settings, set operating parameters, automate device control or check the system status… Mobile Control features all functionalities of a device display. Do you want to record the pressure trace of the pumps? Mobile Control Chrom features data acquisition in addition to full device control. Why to use Mobile Control (Chrom) software Mobile Control is an easy user interface to control one or several devices from one tablet, laptop or PC. The software supports all functionalities of the AZURA devices. Save space: Mobile Control runs on a tablet. Especially in labs with little space avoiding a desktop PC with keyboard and monitor can be a decisive factor. The touch-optimized user interface allows device control using just your fingers. Save time: Mobile Control convinces due to an intuitive user interface and a clearly structured menu function. The training period is minimal in comparison to a complex CDS. Free updates: With every release new features are available in Mobile Control. You can download the current version for free. Free trial: To evaluate if Mobile Control holds up to your expectations, you can download the software and test the free trail option. Perfect for those who’d like to try before they buy. Customized software design: Mobile Control is made by KNAUER and can be adapted to the requirements of our OEM partners. Specifications Software Software name Mobile Control - basic display software for AZURA devices without data acquisition Mobile Control Chrom - basic display software for AZURA devices with data acquisition Operating system Windows 10 Field of application Display software, device control, Expandability This software supports a wide range of instru- Stand-alone yes ments. For more information, please visit Multi-user environment yes www.knauer.net/softwarecontrol Report functions yes Ordering details: Software A9607 Mobile Control for AZURA® devices without data acquisition including 10” tablet and mount A9608 Mobile Control Chrom for AZURA® devices with data acquisition including 10.8” tablet and mount A9610 Mobile Control for AZURA® devices without data acquisition A9612 Mobile Control Chrom for AZURA® devices with data acquisition A9614 Upgrading Mobile Control to Mobile Control Chrom gaining data acquisition Accessories A96181 USB-LAN ADAPTER Network adapter USB 2.0 <-> 10/100 Ethernet for tablets A64809 WLAN Router, 8-port Gigabit RJ-45 A64809INT WLAN Router with international power supply wo plug, 8-port Gigabit RJ-45 A64811 Single device WLAN router for Mobile Control - 1x RJ45, 10/100 MBit; WLAN A9615 Tablet lock with stand for all tablets A9616 Tablet lock for all tablets A9617 Mobile Control Mount - flexible tablet mount for 7-10“ tablets Get the free demo version: www.knauer.net/mobilecontrol KNAUER Dosing Pump Selection Guide | 25 Do you need help choosing the right pump for your application? Ask our friendly support via sales@knauer.net. KNAUER maintains your devices to ensure your process is working without any failure. You can order a preventive maintenance service at your place or simply ship your devices to KNAUER. Do you need more information? Just contact our support team via support@knauer.net. Note: You can maintain the pump and its pump head individually! Our experienced trainers can show you how to maintain the pump head on your own. After the training you are able to perform routine maintenance and repair your pump head in case of malfunctions. Get an offer at academy@knauer.net. Do you observe a decrease of your pump’s flow rate presicion? Just send your pump unit to KNAUER, we will fix that for you. Our pumps can be equipped with several components in order to adapt them to a wide range of dosing tasks (see page 19 and 29). Our service team can install them for you or you can do it yourself after the completion of a KNAUER training. Do you need help in any kind of way? Just call our friendly support team or write an E-mail: Phone: +49 30 809727-111 Email: support@knauer.net 26 | KNAUER Dosing Pump Selection Guide Please visit www.knauer.net/brochures to find more information about KNAUER products and systems. AZURA® Analytical HPLC/UHPLC AZURA® Bio purification AZURA® Preparative HPLC (Document no. V7852US) (Document no. V7855US) (Document no. V7820US) AZURA® SMB systems Freezing point osmometry KNAUER Dosing Pump Selection Guide (Document no. V7741US) (Document no. V7716US) (Document no. V7803US) KNAUER Product Selection Guide KNAUER System Selection Guide KNAUER Column Selection Guide (Document no. V7854-2US) (Document no. V7857US) (Document no. V7803US) KNAUER Dosing Pump Selection Guide | 27 mm inches inches mm Tubing ID μl/cm μl/in 0.10 .004” 1/32” 0.8 .004” 0.08 0.21 0.12 .005” 1/16” 1.6 .005” 0.13 0.32 0.15 .006” 1/8” 3.2 .010” 0.51 1.29 0.25 .010” 1/4” 6.4 .015” 1.14 2.90 0.40 .016” 3/8” 9.5 .020” 2.03 5.15 0.50 .020” 1/2” 12.7 .025” 3.17 8.04 0.75 .030” 1” 25.4 .030” 4.56 11.58 1.00 .040” .040” 8.11 20.59 1.50 .060” .060” 18.24 46.33 2.00 .080” .070” 24.83 63.06 4.60 .180” .085” 36.61 92.99 6.00 .236” 6.40 .253” 7.00 276” 10.00 .400” MPa bar psi °C °F °C °F °C °F 5 50 725 -40 -40 65 149 170 338 10 100 1 450 -35 -31 70 158 175 347 20 200 2 901 -30 -22 75 167 180 356 30 300 4 351 -25 -13 80 176 185 365 40 400 5 802 -20 -4 85 185 190 374 50 500 7 252 -15 5 90 194 195 383 60 600 8 702 -10 14 95 203 200 392 70 700 10 153 -5 23 100 212 205 401 80 800 11 603 0 32 105 221 210 410 90 900 13 054 5 41 110 230 215 419 100 1 000 14 504 10 50 115 239 220 428 110 1 100 15 954 15 59 120 248 225 437 120 1 200 17 405 20 68 125 257 230 446 130 1 300 18 855 25 77 130 266 235 455 140 1 400 20 306 30 86 135 275 240 464 150 1 500 21 756 35 95 140 284 245 473 160 1 600 23 206 40 104 145 293 250 482 170 1 700 24 657 45 113 150 302 255 491 180 1 800 26 107 50 122 155 311 260 500 190 1 900 27 558 55 131 160 320 265 509 200 2 000 29 008 60 140 165 329 270 518 28 | KNAUER Dosing Pump Selection Guide Note: The user takes the responsibility for using the fluids and chemicals in an appropriate and safe way. If there is any doubt, contact the Technical Support of the manufacturer. The device is very resistant against a variety of commonly used eluents. However, make sure that no eluents or water come in contact with the device or enter into the device. Some organic solvents (such as chlorinated hydrocarbons, ether) may cause coating damage or loosen glued components by improper handling. Even small quantities of other substances, such as additives, modifiers, or salts can influence the durability of the materials. Exposure time and concentration have a high impact on the resistance. The following list contains information about the chemical compatibility of all wetted materials which are used in devices made by KNAUER. The data bases on a literature research on the manufacturer specifications of the materials. All resistances mentioned here are for use at temperatures up to 40 ° C, unless stated otherwise. Please note that higher temperatures can significantly affect the stability of different materials. Polyetheretherketone (PEEK) PEEK is a durable and resistant plastic and, next to stainless steel, the standard material in HPLC. It can be used at temperatures up to 100 °C and is highly chemical resistant against almost all commonly used solvents in a pH range of 1-12,5. PEEK is potentially moderate resistant against oxidizing and reducing solvents. Therefore, following solvents should not be used: Concentrated and oxidizing acids (such as nitric acid solution, sulfuric acid), halogenated acids (such as hydrofluoric acid, hydrobromic acid) and gaseous halogens. Hydrochloric acid is approved for most applications. In addition, following solvents can have a swelling effect and may have an impact on the functionality of the built-in components: Methylene chloride, THF and DMSO in any concentration such as acetonitrile in higher concentrations. Polyethylene terephthalate (PET, outdated PETP) PET is a thermoplastic and semi-crystalline material with high wear resistance. It is resistant against diluted acids, aliphatic and aromatic hydrocarbons, oils, fats and alcohols, but not against halogenated hydrocarbons and ketones. Since PET belongs chemically to esters, it is not compatible with inorganic acids, hot water and alkalis. Maximum operating Temperature: up to 120 °C. Polyimide (Vespel®) This material is wear-resistant and permanent resilient thermically (up to 200 °C) as well as mechanically. It is chemically broadly inert (pH range 1-10) and is especially resistant against acidic to neutral and organic solvents, but vulnerable to pH strong chemical or oxidizing environments: It is incompatible with concentrated mineral acids (such as sulfuric acid), glacial acetic acid, DMSO and THF. In addition, it will be disintegrated by nucleophilic substances like ammonia (such as ammonium salts under alkaline conditions) or acetate. KNAUER Dosing Pump Selection Guide | 29 Ethylene-tetrafluorethylene copolymer (ETFC, Tefzel®) This fluorinated polymer is highly resistant against neutral and alkaline solvents. Some chlorinated chemicals in connection with this material should be handled with care. Maximum operating Temperature is 80 ºC. Perfluorethylenpropylen-Copolymer (FEP), Perfluoralkoxy-Polymer (PFA) These fluorinated polymers hold similar features as PTFE, but with a lower operation temperaturte (up to 205 °C). PTA is suitable for ultrapure appilcations, FEP can be used universally. They are resistant against almost all organic and inorganic chemicals, except elemental fluorine under pressure or at high temperatures and fluorine-halogen compounds. Polyoxymethylene (POM, POM-H-TF) POM is a semi-crystalline, high-molecular thermoplastic material which stands out due to its high stiffness, low friction value and thermic stability. It can even substitute metal in many cases. POM-H-TF is a combination of PTFE fibres and acetal resin and is softer and has better slip properties as POM. The material is resistant against diluted acids (pH > 4) as well as diluted lyes, aliphatic, aromatic and halogenated hydrocarbons, oils and alcohols. It is not compatible with concentrated acids, hydrofluoric acid and oxidizing agent. Maximum operating temperature is 100 ºC. Polyphenylene sulfide (PPS) PPS is a soft polymer which is known for its high break resistance and very high chemical compatibility. It can be used with most organic, pH neutral to pH high, and aqueous solvents at room temperaturewithout concerns. However, it is not recommended for using with chlorinated, oxidizing and reducing solvents, inorganic acids or at higher temperatures. Maximum operating temperature: 50 °C. Polytetrafluorethylene (PTFE, Teflon®) PTFE is very soft and anti-adhesive. This material is resistant against almost all acids, lyes and solvents, except against fluid natrium and fluoride compounds. In addition, it is temperature-resistant from -200 °C to +260 °C. Systec AF™ This amorphous perfluorinated copolymer is inert against all commonly used solvents. However, it is soluble in perfluorinated solvents like Fluorinert® FC-75 and FC-40, and Fomblin perfluor-polyether solvents from Ausimont. In addition, it is affected by Freon® solvents. Polychlortrifluorethylene (PCTFE, Kel-F®) The semi-crystalline thermoplastic material is plasticizer-free and dimensionally stable, even in a wide temperature range (−240 °C to+205 °C). It is moderately resistent against ether, halogenated solvents and toluene. Halogenated solvents over +60 °C and chlorine gas should not be used. Fluorinated rubber (FKM) The elastomer consisting of fluorinated hydrocarbon stands out due to a high resistance against mineral oils, synthetic hydraulic fluids, fuels, aromatics, and many organic solvents and chemicals. However, it is not compatible with strong alkaline solvents (pH value >13) like ammonia, and acidic solvents (pH value <1), pyrrole and THF. Operating temperature: Between -40 °C and +200 °C. Perfluorinated rubber (FFKM) This perfluoro elastomer has a higher fluorine content as fluorinated rubber and is therefore chemically more resistant. It can be employed at higher temperatures (up to 275 °C). It is not compatible with pyrrole. 30 | KNAUER Dosing Pump Selection Guide Stainless steel Stainless steel is, apart from PEEK, the standard material in HPLC. Steels with WNr. 1.4404 (316L) are used, or with a mixture of higher compatibility. They are inert against almost all solvents. Exceptions are biological applications which are metal ion sensible, and applications with extreme corrosive conditions. These steels, in comparison to commonly used steels, are increasingly resistant against hydrochloric acid, cyanides and other halogen acids, chlorides and chlorinated solvents. The use in ion cromatography is not recommended. In case of electrochemical applications, a passivation must be executed first. Hastelloy®-C This nickel-chrome-molybdenum alloy is extremely resistant to corrosion, especially against oxidizing, reducing and mixed solvents, even at high temperatures. This alloy may be used in combination with chlor, formic acid, acetic acid and saline solutions. Titanium, titanium alloy (TiA16V4) Titanium has a low weight and a high hardness and stability. It stands out due to its very high chemical compatibility and biocompatibility. Titanium is applied when neither stainless steel nor PEEK are usable. Diamond-like carbon (DLC) This material is characterized by a high hardness, a low coefficient of friction and thus low wear. In addition, it is highly biocompatible. DLC is inert against all acids, alkalis and solvents commonly used in HPLC. Ceramic Ceramic is resistant against corrosion and wear and is fully biocompatible. An incompatibility against acids, alkalis and solvents commonly used in HPLC is not known. Alumina (Al2O3) Due to their high resistance to wear and corrosion, alumina ceramic is used as a coating for mechanically stressed surfaces. It is a biocompatible material with low thermal conductivity and low thermal expansion. Zirconium oxide (ZrO2) Zirconia ceramics are characterized by their high mechanical resistance, which makes them particularly resistant to wear and corrosion. It is also biocompatible, has low thermal conductivity and is resistant to high pressures. Sapphire Synthetic sapphire is virtually pure monocrystalline alumina. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. KNAUER Dosing Pump Selection Guide | 31 Ruby Synthetic ruby is monocrystalline alumina and gets its red color by the addition of some chromium oxide. It is biocompatible and very resistant to corrosion and wear. The material is characterized by a high hardness and a high thermal conductivity. Mineral wool This insulating material consists of glass or stone wool fibres and isolates in high oxidizing conditions and at high temperatures. Mineral wool is valid as commonly inert against organic solvents and acids. Glass, glass fibre, quartz, quartz glass These mineral materials are resistant against corrosion and wear and are mostly chemical inert. They are compatible with oils, fats and solvents and show a high resistance against acids anf lyes up to pH values of 3-9. Concentrated acids (especially hydrofluoric acid) may embrittle and corrode the minerals. Lyes may ablate the surfaces slowly. Max. flowrate 10 & 50 ml/min Stainless steel Ceramic Hastelloy-C Details For water High-temp. High-temp. Ti- For water, piston seal bushings Ti- wash bushings Art. no. 10 ml/min AHB40 AHB40FA AHB40CA AHB40CB AHB32 AHB32DA AHB32GA AHB43 Art. no. 50ml/min AHC20 AHC20FA AHC20CA AHC20CB AHC22 AHC22FA AHC23 AHB43 AZURA® P 2.1S X X X X X X AZURA® P 4.1S X X X X X X BlueShadow 40P X X X X Max. flowrate 100–1 000 ml/min Titanium Stainless steel (biocompatible) Request for more options: Art. no. 100 ml/min A4029-1 A4029V1 sales@knauer.net Art. no. 250 ml/min A4021-1 A4021V1 Art. no. 500 ml/min A4038-1 A4038V2 Art. no. 1 000 ml/min A4022-1 A4022V2 Blueshadow 80P X X 32 | KNAUER Dosing Pump Selection Guide 1. Definition of terms 6.2. Claims for damages The following terms and conditions apply to every order The liability of KNAUER shall be restricted to intentional received by KNAUER and every delivery of goods. This acts and acts of gross negligence and compensation shall holds as well in case of contradictory buying conditions of only be due for direct, foreseeable damages. Liability for the purchaser. Exceptions are only valid when confirmed breach of a material, essential duty of the contract, liability by KNAUER in writing. Purchase orders are only binding if because of personal injury, liability according to the confirmed by KNAUER in writing. stipulations of the German Law on Product Liability and liability for the lack of the condition of the contract goods 2. Payment guaranteed by KNAUER remain unaffected. Deliveries are due and payable, net, within 30 days of 7. Third party rights on industrial or other invoice date or in advance. Deductions are not allowed. Foreign deliveries must be paid by irrevocable letter of intellectual property credit or in advance. All bank and transfer fees must be KNAUER shall not be liable for the infringement of third paid by the customer. The consequences arising out of party rights founded on industrial or other intellectual delay are due to statutory provisions. Payments are due property caused by the use of the delivered goods. The irrespective of an eventual notice of defect, except such customer is fully responsible for the products manufac-defects are evidently justified. tured with the goods. In particular KNAUER is not obliged to indemnify and hold harmless the customer from all 3. Delivery claims raised by third parties based on the infringement of Delivery dates are not binding unless expressly stated in their industrial or intellectual property rights by the use of the contract as binding dates. Delay in delivery requires a the goods. written reminder and an adequate additional grace period set by the customer. KNAUER is only liable for claims for 8. Property rights damages under the requirements of no. 6. The ownership of the goods shall remain with KNAUER until payment in full for all our claims resulting from our 4. Claims business relation is received. In case of improper treatment Condition for any warranty claim is the immediate of the goods or in case of default KNAUER may demand inspection of the goods upon delivery, and complaint the return of the delivered goods. This demand entails towards and damage assessment together with the carrier, resignation of the contract only if KNAUER declares it and an immediate written complaint to KNAUER. The explicitly. complaint must be made within five workdays in case of visible defects or losses. Resellers are allowed to sell the goods to third parties in due course of the business. The customer herewith assigns 5. Risk liability his resale claims against third parties to KNAUER. Delivery is made at the customer's own risk. As soon as the 9. Export goods leave KNAUER's plant the risk of accidental loss, destruction or deterioration passes to the customer. Instruments and products delivered by KNAUER may not be exported to a country other than of the customer's 6. Warranty and damages headquarters without KNAUER's prior written permission. 6.1. Warranty claims 10. Place of settlement and court of jurisdic The warranty begins with receipt of the goods. If commis-tion sioning has been ordered, after commissioning. In the case The place of performance is Berlin. Proper venue for all of delayed commissioning, the warranty begins at the claims is the competent local court at KNAUER's principal latest four weeks after receipt of the goods unless the place of business - Berlin. KNAUER reserves the right to supplier is responsible for delayed commissioning. sue the customer at his principal place of business. The warranty for osmometers and liquid chromatography This agreement shall be governed by the laws of the instruments is limited to two years, excluding glass Federal Republic of Germany excluding the UN-Conven-breakage, damages due to stoppage and consumable tion on the International Sale of Goods (CISG). materials such as membranes, light bulbs, columns, bushings, gaskets and valves. KNAUER's liability shall be restricted to the replacement of defective material or repair only. Transportation costs are borne by the custom-KNAUER Wissenschaftliche Geräte GmbH er. In case of failure of replacement or repair the customer may demand a reduction in price or cancellation of the Hegauer Weg 38 contract with respect to the defective material. The customer has to inspect the goods delivered immediately 14163 Berlin, Germany and shall immediately give written notification of any defects to KNAUER, in case of non-obvious defects within 10 working days after delivery at the very latest. These terms and conditions apply since June 1, 2016 KNAUER Dosing Pump Selection Guide | 33 34 | KNAUER Dosing Pump Selection Guide KNAUER Dosing Pump Selection Guide | 35 Technical data or prices are subject to change without All trademarks are the property of their respective owners. notice. Prices may vary by country and do not include taxes, Our general terms and conditions apply: customs duties or delivery. www.knauer.net/terms . Distributed by: er .0 ap n 2 ly pd ersio S, v tally frienen 7866U m 019 V viron en ER 2U on AN © K Printed KNAUER +49 30 809727-0 Wissenschaftliche Geräte GmbH +49 30 8015010 (Fax) Hegauer Weg 38 info@knauer.net 14163 Berlin, Germany www.knauer.net Document Outline Dosing pump configurator Overview High-pressure dosing pumps Flow-pressure range Chemical compatibility Connectivity Accurate dosing for demanding applications Temperature control Dosing pumps BlueShadow Pump 80P AZURA® Pump P 2.1S AZURA® Pump P 4.1S Mass flow controllers Pump accessories Consumables Software Services KNAUER brochures Chemical compatibility of wetted parts Pump head compatibility Conversion tables Terms and conditions