NIRS XDS Interactance OptiProbe Analyzer Robust measuring system for monitoring reactions in technical centers and pilot plants 02 The NIRS XDS Interactance OptiProbe Analyzer enables straightforward and reliable monitoring of chemical reactions both in the technical center and in pilot plants. The NIRS XDS Interactance OptiProbe Analyzer provides pre-cise results on the identity and quality of many different samples in method development as well as in the scale-up of production processes. While the reflection probe measures solids, highly disper-sive liquids and slurries, the immersion probe is used to analyze aqueous products, clear liquids, and solvents. The probe is connected to the analyzer via an optical fiber, which enables it to take reliable measurements even in the harsh conditions of the process environment. The NIRS XDS Interactance OptiProbe Analyzer is ideal for: • monitoring reactions in both technical centers and pilot plants • developing methods and scaling up production processes User benefits 03 • Simple and efficient monitoring of chemical reactions • Saves time and money – no need to prepare samples; provides analytical results in real-time • Universal application, suitable for both liquids and solids Key features • Quick probe changeover for liquids and solids • Network-compatible – central result and data management (client-server solution) • Universal interface for quickly changing the measuring modules in just a few seconds Technical specifications Measuring mode Reflection and transflection Sample interface Direct analysis Wavelength range 400–2,500 nm Measuring module Hot-swappable Detectors Silicon (400–1,100 nm), lead sulfide (1,100–2,500 nm) Data collection speed 2 scans/s Data point interval 0.5 nm Wavelength accuracy < 0.08 nm (SRM 1920) (currently recognized standard) Wavelength precision1 < 0.008 nm Wavelength precision2 (instrument to instrument) < 0.025 nm Stray light < 0.1% at 2,300 nm Photometric linearity < 1% of the measured value Bandpass 8.75 ±0.10 nm Noise (RMS) 400–700 nm < 80 micro AU 700–2,200 nm < 30 micro AU Weight 34.0 kg (74.0 lbs) Dimensions (W × H × D) 455 × 346 × 559 mm (17.9" × 13.6" × 22") Operating temperature range 4.5–35°C (40–95°F) Relative humidity 10–90% RH, non-condensing 1 based on a single analyzer 2 based on a group of analyzers Ordering information 2.921.1510 NIRS XDS Interactance OptiProbe Analyzer Comprised of: 1.921.0010 NIRS XDS Monochromator 1.921.0510 NIRS XDS Interactance OptiProbe Module 6.7400.000 NIRS XDS accessory kit 6.7430.080 Interchangeable probe as an assembly 8.912.8006EN Manual for NIRS XDS Interactance OptiProbe Requires Vision Air software (select one of the following versions) 6.6072.208 Vision Air 2.0 Complete 6.6072.207 Vision Air 2.0 Network Complete 6.6072.209 Vision Air 2.0 Pharma Complete 6.6072.210 Vision Air 2.0 Pharma Network Complete Requires certified standards 6.7450.030 NIRS 99% reflection standard for lab probes Additional required certified standards (select one of the following) 6.7450.000 NIRS reflection standard, set of 2 6.7450.010 NIRS reflection standard, set of 7 (for the regulated range) witzerland G, CH-9100 Herisau, S ohm A witzerland at Metr www.metrohm-nirs.com , printed in S SW -02 Subject to change Layout by Ecknauer+Schoch A 8.921.5011EN – 2017